http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
배합 특성, 해양 환경 노출 조건 및 기간이 GGBFS 콘크리트의 염해 거동에 미치는 영향성
윤용식 ( Yoon Yong-sik ),정기찬 ( Jeong Gi-chan ),권성준 ( Kwon Seung-jun ) 한국구조물진단유지관리공학회 2022 한국구조물진단유지관리공학회 학술발표대회 논문집 Vol.26 No.1
본 연구에서는 선행 연구에서 분석된 GGBFS 콘크리트의 겉보기 염화물 확산계수 결과를 인용하여 물-결합재 비, GGBFS 치환률, 노출 기간이 염해 거동에 미치는 영향을 해양 노출 조건을 고려하여 분석하였다. 해양환경 노출 조건으로서 침지대, 간만대, 비말대를 고려하였으며 사용 배합은 3수준의 물-결합재 비 및 GGBFS 치환률이 고려되었다. 침지대의 경우 영향인자들의 영향을 가장 크게 받았으며 물-결합재 비는 모든 노출조건에서 가장 지배적인 인자로 평가되었다.
윤용식(Yong-Sik Yoon),이동주(Dong-Ju Lee),박요창(Yo-Chang Park) 한국생산제조학회 2005 한국생산제조학회지 Vol.14 No.3
An accuracy of theodolite system may be affected by a measurement environment and a measurement distance change from theodolite to scale bar and/or targets. This study was performed for measuring an accuracy when the distance from thodolite system to scale bar was changed 2~6m on the distance 4m between two theodolites. The results showed that an accuracy was ±0.025mm or better when the distance from theodolite system to targets was 3, 4 and 5m. According to the results, it was found that the best distance from theodolite system to scale bar was 3~4m when the collimation distance was 3~4m.
윤용식 ( Yong Sik Yoon ),박인자 ( In Ja Park ),이강홍 ( Kang Hong Lee ),김희철 ( Hee Cheol Kim ),유창식 ( Chang Sik Yu ),김진천 ( Jin Cheon Kim ) 대한소화기학회 2004 대한소화기학회지 Vol.44 No.5
Background/Aims: Small bowel diverticulum is a rare disease that can be found incidentally during a surgical operation. Since reported complication rate is low, uncomplicated small bowel diverticula are generally recommended to be untreated. The aim of th
UV 폭로 및 동결융해 시험을 거친 FRP Hybrid Bar의 인장거동 평가
윤용식(Yong-Sik Yoon),박재성(Jae-Sung Park),박기태(Ki-Tae Park),권성준(Seung-Jun Kwon) 한국건설순환자원학회 2017 한국건설순환자원학회 논문집 Vol.5 No.2
본 연구에서는 UV 폭로 및 동결융해 환경이 FRP Hybrid Bar의 인장거동 및 표면 열화에 미치는 영향을 평가하기 위해 FRP Hybrid Bar를 대상으로 UV 폭로 및 동결융해 시험을 실시하였다. FRP Hybrid Bar의 경우 UV 폭로 및 동결융해 180cycle 시험 전/후 외관적인 열화가 거의 발생하지 않았다. 또한 FRP Hybrid Bar의 주요 장점 중 하나인 인장경화특성은 동결융해시험을 거친 이후에도 유지되었는데, 이는 UV 폭로시험을 거친 FRP Hybrid Bar에도 유효하게 평가되었다. UV 폭로시험을 거친 FRP Hybrid Bar는 일반 FRP Hybrid Bar와 거의 비슷한 인장거동을 나타내었으며, 동결융해 180cycle의 진행에도 불구하고 일반철근, FRP Hybrid Bar, UV 폭로를 거친 FRP Hybrid Bar의 인장거동은 큰 변화를 나타내지 않았다. 본 연구에서는 UV 폭로 및 동결융해 환경이 FRP Hybrid Bar의 외관 및 인장 특성에 큰 영향을 미치지 못하는 것으로 판단되지만, 충격에 따른 규사코팅의 박락은 콘크리트와의 부착력에 영향을 미치므로 이에 대한 고려가 필요하다. The present work is for an evaluation of tension behavior and surface deterioration of FRP Hybrid Bar due to UV exposure and freezing/thawing(F/T) actions. For the work, FRP Hybrid Bar is subjected to UV exposure test, then F/T test is performed successively to 180 cycles. In FRP Hybrid Bar, no significant surface deterioration is evaluated after UV exposure. Tension hardening performance, a unique engineering advantage of FRP Hybrid Bar, is still maintained after F/T test. The performance in FRP Hybrid Bar exposed to UV is still effective. FRP Hybrid Bar exposed to UV have almost similar tension behavior of FRP Hybrid Bar without UV exposure. Although F/T cycles increase to 180, steel rebar, FRP Hybrid Bar, and FRP Hybrid Bar exposed to UV show no significant changes in tension behavior. In the work, UV exposure and F/T actions are evaluated to have little negative effect on surface deterioration and tensile performance in FRP Hybrid Bar, however spalling of silica coating due to impact should be considered since it affects bonding strength to outer concrete.
시멘트계 보수재료로 코팅된 강재의 부식 및 휨강성 평가
윤용식(Yong-Sik Yoon),김태상(Tae-Sang Kim),김호룡(Ho-Ryong Kim),권성준(Seung-Jun Kwon) 한국건설순환자원학회 2016 한국건설순환자원학회 논문집 Vol.4 No.3
본 연구에서는 시멘트계 보수재 코팅이 철판의 부식 저항성에 미치는 영향을 평가하가 위해 보통 철판(Normal), 용접철판(Welding), 용접 후 보수재 철판(Welding & coating)의 세 가지 경우에 대하여 7일간 ICM(Impressed Current Method)를 통하여 부식을 촉진시켰다. 이후 Faraday 법칙을 통해 얻은 이론 부식률, 실험 부식률 그리고 부식 실험 후 측정한 휨 강도를 비교평가하였다. Normal case와 Welding case에서는 약 70% 수준의 부식률이 측정되었으며, Welding & coating case에서는 약 17%정도의 부식률이 측정되었다. 이는 시멘트계 보수재료의 코팅이 염화물 이온의 침투를 효과적으로 차단하였으며 이로인해 부식전류의 발생이 억제되었기 때문이다. 휨 강도 역시 부식률 평가와 같은 경향을 나타내었으며 Welding & coating case에서 Welding case 대비 약 3.4배 큰 강도가 평가되었다. 시멘트계 보수재 코팅이 용접부에 시행되면 용접부 철판의 부식 차단에 효과적일 것으로 판단된다. The present work is for an evaluation of resistance to corrosion in steel coated with cementitious repair material, so that 3 cases of steel plate(Normal, Welding, Welding & coating case) are subjected to ICM(Impressed Current Method) for acceleration of corrosion for 7days. Tested and estimated corrosion ratio through Faraday’s Law are compared, and the related flexural strength are evaluated. In Normal and Welding cases, similar level of corrosion ratio(70%) is evaluated, however only 17% level of corrosion ratio is evaluated in the Welding & coating case, which indicates that cementitious repair material is effective to anti-corrosion due to a block of chloride penetration. The flexural test results are consistent with those in accelerated corrosion test, which shows a significant flexural strength in Welding & coating case by 3.4times greater than the others. The cementitious material repair coating is evaluated to be effective to anti-corrosion in welding of steel plate.
윤용식 ( Yong Sik Yoon ),이수란 ( Su Ran Lee ),손영우 ( Young Woo Sohn ) 한국항공운항학회 2012 한국항공운항학회지 Vol.20 No.1
Air traffic controllers often experience fatigue and stress on the job due to work-related factors. Performance impairment resulting from fatigue and stress is an important concern for aviation safety. The goal of this research was to investigate fatigue and stress factors for air traffic controllers. The research involved an extensive literature review of fatigue and stress in the air traffic control environment and surveyed fatigue and job stress level of Korean air traffic controllers compared to other occupation groups. Results of survey showed that fatigue and stress levels of air traffic controllers were significantly higher than other occupation groups. Specially air traffic controllers reported that night work created high level of fatigue and perceived that physical environment and job demand induced high level of stress. In addition, implications for fatigue and stress management were discussed.
메인 메모리 DBMS P^*TIME 기반 WAP 서버 구현
윤용식(Yong-Sik Yoon),노재윤(Jae-Yun No),송창빈(Chang-Bin Song),차상균(Sang-Kyun Cha) 한국정보과학회 2001 한국정보과학회 학술발표논문집 Vol.28 No.2Ⅰ
최근 개인 휴대폰의 대중화에 따라 기존의 유선 인터넷 환경과 휴대폰 서비스가 결합된 무선 인터넷 서비스가 각광을 받고 있다. 현재 웹을 기반으로 WAP 인터페이스를 제공하는 회사들은 디스크 기반 DBMS를 사용한다. 데이터의 전송 속도가 유선 상에 비해 떨어지고 회선이 불안정한 무선 인터넷의 특성상, 응답 시간이 느릴 경우 사용자는 서비스 이용에 큰 불편을 느낄 수밖에 없고, 이용상에 오류가 생길 가능성이 높아진다. 이에 비추어 볼 때 응답 시간을 기존의 유선 인터넷 서비스에 비해 더욱 중요한 요소로 작용한다. 디스크 기반 DBMS는 이와 같은 요구 조건을 만족하지 못한다. 그에 반해 구조가 간단하면서 높은 성능을 낼 수 있는 메인 메모리 DBMS는 무선 인터넷 서비스에 적합한 환경을 제공한다. 본 논문에서는 2세대 고성능 메인 메모리 DBMS인 P^*TIME을 이용하여 무선 인터넷 서버를 구현하고, 그 성능을 상용 DRDBMS인 Oracle을 이용했을 때의 성능과 비교 분석해 본다. WML, WML Script, JSP를 이용하여 PIMS 서비스를 구현해 본 결과, 동시 접속사 수가 늘어남에 따라 Oracle과 P^*TIME의 성능 차이는 더욱 크게 벌어져 동시 접속사 수가 50명일 경우 P^*TIME이 100배 이상의 성능을 보였다.
주기적인 염수의 건습을 고려한 RC 시편의 장기 부식 모니터링 결과
윤용식 ( Yoon Yong-sik ),이현우 ( Lee Hyeon-woo ),정종민 ( Jeong Jong-min ),권성준 ( Kwon Seing-jun ) 한국구조물진단유지관리공학회 2022 한국구조물진단유지관리공학회 학술발표대회 논문집 Vol.26 No.2
본 연구에서는 RC 구조 내 철근의 부식을 가속시키기 위해 2년간 염수를 이용한 건조 습윤 실험을 수행하였으며, 교체가능형 agar 센서를 이용하여 조건별 OCP를 측정하였다. 3 수준의 염화물 농도, 물-시멘트 비 및 피복두께를 고려한 약 2년간 부식 모니터링을 수행하였다. 물-시벤트 비가 0.6인 경우 모니터링 6개월 경과 후부터 부식 전위가 크게 감소하여 일부 조건에서는 임계 부식 전위(-450 mV) 이하의 값들이 평가되었다.
주기적인 염수의 건습을 고려한 RC 시편의 장기 부식 모니터링 결과
윤용식 ( Yoon Yong-sik ),이현우 ( Lee Hyeon-woo ),정종민 ( Jeong Jong-min ),권성준 ( Kwon Seing-jun ) 한국구조물진단유지관리공학회 2022 한국구조물진단유지관리공학회 학술발표대회 논문집 Vol.26 No.2
본 연구에서는 RC 구조 내 철근의 부식을 가속시키기 위해 2년간 염수를 이용한 건조 습윤 실험을 수행하였으며, 교체가능형 agar 센서를 이용하여 조건별 OCP를 측정하였다. 3 수준의 염화물 농도, 물-시멘트 비 및 피복두께를 고려한 약 2년간 부식 모니터링을 수행하였다. 물-시벤트 비가 0.6인 경우 모니터링 6개월 경과 후부터 부식 전위가 크게 감소하여 일부 조건에서는 임계 부식 전위(-450 mV) 이하의 값들이 평가되었다.
주기적인 염수의 건습을 고려한 RC 시편의 장기 부식 모니터링 결과
윤용식 ( Yoon Yong-sik ),이현우 ( Lee Hyeon-woo ),정종민 ( Jeong Jong-min ),권성준 ( Kwon Seing-jun ) 한국구조물진단유지관리공학회 2022 한국구조물진단유지관리공학회 학술발표대회 논문집 Vol.26 No.2
본 연구에서는 RC 구조 내 철근의 부식을 가속시키기 위해 2년간 염수를 이용한 건조 습윤 실험을 수행하였으며, 교체가능형 agar 센서를 이용하여 조건별 OCP를 측정하였다. 3 수준의 염화물 농도, 물-시멘트 비 및 피복두께를 고려한 약 2년간 부식 모니터링을 수행하였다. 물-시벤트 비가 0.6인 경우 모니터링 6개월 경과 후부터 부식 전위가 크게 감소하여 일부 조건에서는 임계 부식 전위(-450 mV) 이하의 값들이 평가되었다.