        보도교 상판의 감쇠율 분석

        윤성원,문상현,Yoon, Sung-Won,Moon, Sang-Hyouen 한국공간구조학회 2014 한국공간구조학회지 Vol.14 No.4

        In Seoul, total 27 places of foot-bridges were chosen to evaluate the damping ratio through vibration measurement by mobile-phone application. Model vibration test was performed to compare the natural frequency and damping ratio between the conventional accelerometer and mobile-phone application. Measured average damping was compared with the one of Bachmann. The relation between the damping ratio and span was also investigated. Measured average damping ratio was greater than that of Bachmann. It was shown that there is no distinct trend between damping and span.

      • KCI등재후보

        고층건물 현장계측을 통한 거스트 계수 제안

        윤성원,김도현,김영문,김동원,Yoon, Sung-Won,Kim, Do-Hyun,Kim, Young-Moon,Kim, Dong-Won 한국공간구조학회 2008 한국공간구조학회지 Vol.8 No.1

        건물에 설치된 모니터링 시스템으로부터 기록된 바람과 구조물의 반응으로부터 평균풍속, 풍향, 난류강도, 거스트팩터를 산정하였다. 계측된 건물은 각각 속초와 부산에 위치한다. 거스트 계수와 난류강도사이의 관계를 이용하여 계측된 데이터로부터 이들 간의 상관관계식을 제안하였다. 계측된 데이터로부터 얻은 거스트 계수 관계식은 풍동실험과 고층건물설계의 타당성에 유용한 자료로 이용될 수 있다. The wind monitoring systems are installed in high-rise buildings to record wind response data. The measured buildings are located in Busan and Sokcho. The measured wind data are analysed in this paper to obtain the mean wind speed and direction, turbulence intensity and gust factor. By using the correlation between gust factor and turbulence intensity, the expression for gust factor based on wind data measured from the building is suggested. The field measurement data obtained here are useful for the validation of wind tunnel tests and the future design of tall building.

      • KCI등재

        국내외 장스팬 구조물의 고유진동수 비교

        윤성원,박용,Yoon, Sung-Won,Park, Yong 한국공간구조학회 2009 한국공간구조학회지 Vol.9 No.1

        최근의 대공간구조물은 장스팬화 됨은 물론이고 경량화되면서 면외 방향의 강성이 매우 작아지고 있다. 이로 인하여 공력불안정 진동의 발생 여부는 물론이고 연성구조물의 판단시에도 고유진동수의 정확한 산정이 필요하다. 그러나 국내외 대공간구조물의 고유진동수 제안식에 대한 연구는 매우 미흡한 실정이다. 따라서 국내 7개 공간구조물의 고유치해석에서 얻은 근사식을 일본건축학회 고유치해석에 근거한 2가지 제안식과 일본의 28개 공간구조물의 계측치에서 얻은 고유진동수 근사식을 비교하였다. 지붕의 고유진동수는 스팬이 증가함에 따라서 작아지는 경향을 확인하였다. 국내의 고유진동수 값은 전반적으로 일본의 공간구조물의 해석과 계측에 근거한 고유진동수보다 동일한 스팬에서 작은 경향을 보임을 알 수 있었다. 따라서 국내 공간구조물의 지붕은 일본의 경우보다 비교적 연성구조물인 것을 확인할 수 있다. As a recent spatial structure have become long-spaned and light, stiffness of out-plane is reduced significantly. Due to this, it is necessary to calculate natural frequency correctly to check if structure is flexible or vortex-induced vibration is occurred. However, formula of frequency in domestic and foreign spatial structure has not been performed deeply. In this study, approximated formula obtained by eigenvalue analysis of seven domestic spatial structure is compared with two suggestions based on Japanese standard and formula by measurement of 28 spatial structure in Japan. Natural frequency of roof has a tendency to be reduced as the span of structure increases. Natural frequency of domestic structure is generally less than that of analysis and measurement of spatial structure in Japan. Therefore, it is confirm that roof of domestic spatial structure is relatively rather flexible than that of Japan.

      • KCI등재

        강풍시 고층건물의 진동특성 및 사용성 평가

        윤성원,김도현,정석창,김동원,Yoon, Sung-Won,Kim, Do-Hyun,Jeong, Sug-Chang,Kim, Dong-Won 한국공간구조학회 2007 한국공간구조학회지 Vol.7 No.5

        철골조 고층건물을 대상으로 풍응답계측을 실시하여, 감쇠율과 고유진동수의 진폭의존성을 검토하였다. 진폭의존성의 검토를 위하여 RD법을 사용하였다. RD법에 의한 진동특성을 하프파워법에 의한 진동특성과 비교하여 두 방법 사이의 상관관계를 분석하였다. 또한 일본, 캐나다기준에 의한 강풍시의 사용성평가를 통하여 두 가지 방법의 적용성을 검토하였다. RD법에 의하여 감쇠율의 진폭의존성을 확인하였으며, 고유진동수의 진폭의존성은 공학적인 의미에서 상대적으로 매우 작은 것을 확인하였다. 또한 계측건물은 사용성을 만족하였으며, 일본기준이 캐나다기준보다 더욱 엄격함을 확인하였다. After measuring wind induced response for a high-rise steel building, the damping ratio and natural frequency were analyzed in this paper. In order to examine amplitude dependence, random decrement method was used. Two methods were analyzed by comparing dynamic properties from random decrement method and half powered-band width method. In addition, through serviceability evaluation during strong wind, compatibility of two methods to Japanese guidelines for the evaluation of habitability to building vibration and national building code of Canada was considered. The amplitude dependence of the damping ratio by RD method was shown and the amplitude dependence of the natural frequency was relatively very small in an aspect of engineering sense. Moreover, the measured building was satisfied with serviceability and Japanese guideline is stricter than NBCC code.

      • KCI등재

        가성 부갑상선 기능저하증의 이형 석회화 치험례

        윤성원,송재용,김정헌,Yoon, Sung-Won,Song, Jea-Yong,Kim, Chung-Hun 대한성형외과학회 2010 Archives of Plastic Surgery Vol.37 No.3

        Purpose: Pseudohypoparathyroidism is a hereditary disorder characterized by symptoms and signs of hypoparathyroidism, typically in association with distinctive skeletal and developmental defects. Hypoparathyroidism is caused by a insufficient end-organ response to PTH (parathyroid hormone). Hypoparathyroidism consists of four types in which the most common form, pseudohypoparathyroidism-Ia, accompany with Albright's hereditary osteodystrophy. We experienced a case of a woman who had been suffering from calcified mass on left foot, diagnosed Albright's hereditary osteodystrophy. Methods: We present a case of a 24-year-old Korean female who visited plastic surgery department with a painful mass on dorsum of the left foot. On the physical exam, bony hard and painful mass, fixed to dermis, was noted. Plain X-ray films demonstrate suspicious calcification on subcutaneous tissue of dorsum of the left foot. The patient was diagnosed pseudohypoparathyroidism 2 years ago at the plastic surgery department. At the visiting time, the laboratory results were within normal range even though the patient actually had a disease. The reason is because the patient has been treated with Vit.D, calcium replacement therapy and thyroid hormone therapy. Moreover, the patient has been treated with anticonvulsant agents due to epilepsy. On the brain computer tomography (CT), calcification was noted on the basal ganglia and dentate nucleus. So we decided the total excision of entire mass from the left foot. Results: We excised main mass with numerous pinhead sized masses which were scattered around the main mass. The $6.0{\times}4.0{\times}0.5\;cm$ sized main mass was bony hard, and its surface was flat and margin was irregular. The permanent biopsy was confirmed that the main mass and all the scattered tiny masses were heterotopic calcification. The patient did not suffer from the pain after the mass excision. The wound has been healed without any problem. Conclusions: Heterotrophic calcification is often accompanied with pseudohypoparathyroidism, but such a huge one is uncommon. We report a case of pseudohypoparathyroidism with heterotrophic calcification developed in dorsum of left foot who was diagnosed by excisional biopsy.

      • KCI등재
      • KCI등재
      • KCI등재후보

        버스와 지하철 진동에 대한 중층건물의 진동특성

        윤성원,Yoon, Sung-Won 한국공간구조학회 2007 한국공간구조학회지 Vol.7 No.4

        This paper is concerned with the vibration characteristics of medium-rise building, which severely vibrated by vehicles. The field vibration measurement was employed for finding the vibration source and vibration reducing method. Time domain data from measurements were also utilized for vibration characteristics, such as effect of buses and subways-induced vibration on the floor vibration of the building. effectiveness of the vibration reducing method was also demonstrated. 교통진동의 영향을 받는 중층건물의 진동특성에 관한 논문이다. 현장진동계측은 진동원과 진동감소대책을 위하여 실시되었다. 시간영역 진동데이터는 버스와 지하철로 인한 건물에 전달된 진동 영향 등의 진동특성을 위하여 이용되었다. 진동대책을 통한 진동감소의 효과 역시 입증할 수 있었다.

      • KCI등재

        실측을 통한 건물의 손상 전.후 진동특성 평가

        윤성원,박용,Yoon, Sung-Won,Park, Yong 한국강구조학회 2010 韓國鋼構造學會 論文集 Vol.22 No.5

        Recently, the remodeling projects of old low-rise buildings were launched in Korea. However, most of them were not satisfied with the value set forth by the KBC2005. Even though there are some research studies on how to improve the seismic performance of such buildings as newly constructed buildings, there is little research in measuring the actual vibrations on low old buildings to prove the effect of retrofit. There also has not been any in-depth research on the dynamic characteristics of full-scale structures using vibration measurements of the building that was damaged to failure. Using an actuator, the dynamic characteristics of reinforced three-storey concrete buildings were evaluated before and after they were damaged. After an 80-mm horizontal displacement by the actuator, frequency in the long and short directions were reduced to 20.85% and 5.77% respectively ; damping ratio was also reduced to 53.9% and 23.15% respectively. 최근 추진되는 노후화된 저층형 건물의 리모델링의 대부분이 국내기준인 KBC2005의 내진성능에 미치지 못하는 실정이다. 이에 보강을 통한 신축건물과 견줄 수 있는 성능확보에 대한 연구가 많이 이루어지고 있으나, 실제건물의 진동계측을 통해 보강효과를 검증하는 연구는 상대적으로 매우 미흡한 실정이다. 또한 실물 구조물에 대하여 파괴 직전까지의 큰 손상 후에 진동계측을 통한 동적특성에 대한 연구도 매우 미약한 실정이다. 따라서 본 연구는 3층 철근콘크리트조 건물에 강판벽을 보강한 후 엑츄에이터로 하중을 주어 건물에 손상을 준 후에 손상 전 후의 진동 계측을 통하여 동적특성을 파악하였다. 진동계측을 통하여 보강효과를 확인할 수 있었다. 또한 80mm의 수평변위를 준 결과 구조물의 파괴 직전 손상 전 후에 장변과 단변의 고유진동수는 각각 20.85%, 5.77% 감소하였고, 감쇠율은 각각 53.9%, 23.15% 감소하였다.