남지연(Nam Jee-Yeon),이용준(Lee Yong-Jun),신지웅(Shin Jee-Woong),박영기(Park Young-Ki),이경회(Lee Kyung-Hoi) 대한건축학회 2003 대한건축학회 학술발표대회 논문집 - 계획계/구조계 Vol.23 No.2
After the liberalization policy of housing supply price in 1998, the similar and simple external appearance of the Apartment House is slowly changed into diverse and characteristic form in the facade, detail, and exterior finishing materials and so on. This change is caused by the competition between construction companies.<br/> In this study, the relationship between design of apartment components and consumers' visual preference was surveyed focused on the external appearance. Especially the divergence of exterior design before and after the liberalization policy was concerned. The result shows that consumers' visual preference were influenced by the facade design of each unit, lower part of building design and entrance design and so on by order. and The preference of whole building partially has relationship with the each component.
SSIM 및 VLSW 알고리즘을 활용한 결측치가 포함된 건물에너지관리시스템 데이터로부터의 에너지소비량 예측에 관한 연구
QUAN JUNLONG,신지웅(Jee-Woong Shin),고정림(Jeong-Lim Ko),신승권(Seung-Kwon Shin) 대한전기학회 2021 전기학회논문지 Vol.70 No.10
BEMS provide energy forecasting capabilities for effective energy management. Energy consumption prediction requires complete time series data, including missing data sets that may lead to biased results. However, it is a common problem that BEMS data is not measured due to power failure, communication barrier, maintenance and other reasons. Therefore, a solution is required for missing values. The existing methods will affect the results of the prediction model in the case of continuous missing interval or small amount of data. Therefore, this study uses VLSW algorithm which can generate fully learned data with only a small amount of data and SSIM model based on it to study the scheme to improve the prediction accuracy of building energy data set including missing values, and compares the difference with existing models. The results show that the SSIM model has better prediction accuracy than the existing LSTM technology. The concentration range of ASHRAE error level was satisfactory.
손원득(Won-Tug Son),장환(Hwan Jang),신지웅(Jee-Woong Shin),김종민(Jong-Min Kim),박찬석(Chan-Seok Park),조종선(Jong-Sun Cho) 대한설비공학회 2012 대한설비공학회 학술발표대회논문집 Vol.2012 No.6
This study has been conducted to propose an optimal design guidance of underfloor air distribution system by examining air pattern and proper exhaust status of floor plenum using CFD (Computational Fluid Dynamics). Simulation shows deficient air pattern and exhaust status at BPG (Bypass Grille) of the current design. As a means to find an alternative design, four cases have been developed and tested. Case 1,2 and 3 show similar results in comparison to the current design. However, case 4 shows improved air pattern and exhaust status at BPG(Bypass Grille), and has been chosen as the optimal alternative.