http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
송해은,원안나,김성용,이찬호,황정하 한국건축친환경설비학회 2018 한국건축친환경설비학회 논문집 Vol.12 No.1
This study classified the space types of respiratory disease ward departments, in which secondary airborne infection is expected, into three and selected the ward department of M hospital with space type I as a target building. On-site visits were made to the wards, hallways, and rest areas of the ward department to measure indoor airflow, which was analyzed using the Star-ccm+ software. In the existing air-conditioning state, airflow occurred between one-person wards and the hallway, between five-person wards and the hallway, and between hallways and rest areas, indicating the possibility of secondary airborne infection in the hospital. As a measure to improve the secondary infection prevention in the hospital, [ALT-1] with zoning changes and partition door installation, [ALT-2] with ward rearrangement, and [ALT-3] with ward rearrangement and partition door installation were proposed. Among them, [ALT-3] was considered to have the low probability of air-borne infection because airflow mixing between wards did not occur.
실시간 계측을 통한 버스 내외부의 미세먼지 농도 변화에 관한 연구
송해은(Hae-Eun Song),강율호(Yul-Ho Kang),우상무(Sang-Moo Woo),양수광(Su-Kwang Yang),진혁(Hyuk Jin),이형(Hyung Lee),안영철(Young-Chull Ahn) 대한설비공학회 2022 대한설비공학회 학술발표대회논문집 Vol.2022 No.6
미세먼지는 인체 건강에 직접 영향을 주며, 다양한 질병들을 일으키는 해로운 대기 오염물질이다. 2018 세계 공기질 보고서-지역 & 도시 PM2.5(초미세먼지)에 따르면, 우리나라의 초미세먼지 오염도는 칠레에 이어 경제협력개발기구(OECD) 회원국 중 2위로 나타났다. 대부분의 도시에서 많이 사용하고 있는 대중 교통 수단인 버스는 외부 영향과 승객의 수에 따라 오염도가 나타난다. 본 연구에서는 버스의 실내와 실외에 설치된 미세먼지 센서를 통해 버스의 내부와 외부에서의 미세먼지 특성을 분석하고자한다.
실시간 계측을 통한 버스 내외부의 미세먼지 농도 변화에 관한 연구
송해은(Hae-Eun Song),강율호(Yul-Ho Kang),우상무(Sang-Moo Woo),양수광(Su-Kwang Yang),진혁(Hyuk Jin),이형(Hyung Lee),안영철(Young-Chull Ahn) 대한설비공학회 2022 대한설비공학회 학술발표대회논문집 Vol.2022 No.6
미세먼지는 인체 건강에 직접 영향을 주며, 다양한 질병들을 일으키는 해로운 대기 오염물질이다. 2018 세계 공기질 보고서-지역 & 도시 PM2.5(초미세먼지)에 따르면, 우리나라의 초미세먼지 오염도는 칠레에 이어 경제협력개발기구(OECD) 회원국 중 2위로 나타났다. 대부분의 도시에서 많이 사용하고 있는 대중 교통 수단인 버스는 외부 영향과 승객의 수에 따라 오염도가 나타난다. 본 연구에서는 버스의 실내와 실외에 설치된 미세먼지 센서를 통해 버스의 내부와 외부에서의 미세먼지 특성을 분석하고자한다.
교실내 공기청정기의 설치 위치에 따른 공기 청정도 평가에 관한 연구
송해은(Hae-Eun Song),강율호(Yul-Ho Kang),양수광(Soo-Kwang Yang),안영철(Young-Chull Ahn) 대한설비공학회 2020 대한설비공학회 학술발표대회논문집 Vol.2020 No.6
최근 한국은 미세먼지 발생 빈도의 증가 및 고농도화에 따른 실내 공기질 확보에 대한 수요와 관심이 증대되고 있으며, 환기 장치를 통한 미세 먼지 제어에 대한 기술적 요구가 높아지고 있다. 실내 미세먼지 제거를 위해 다양한 형태의 공기청정기가 널리 보급되어 적용되고 있으나 설치 위치와 풍량에 따른 효과에 대한 적절한 관리 기준은 미비한 실정이다. 한국의 교실에 설치되고 있는 환기 장치는 학생들의 편의와 공간을 고려하여 천장형 또는 스탠드형으로 설치된 곳이 대부분이며, 공기청정기의 송풍량은 시간당 환기횟수 기준으로 최대 3~4회 수준이다. 본 연구에서는 스탠드형의 공기청정장치가 설치된 것으로 가정하고, 송풍량에 따른 교실 내부의 입자 농도 변화를 해석하였다. 공기청정기의 송풍량은 시간당 환기횟수 기준으로 각각 1, 2, 3, 4, 5인 경우에 대하여 해석을 수행하였다. 환기횟수가 2~5 인 조건에서는 case 1의 공기청정기 위치 조건에서 대부분의 시간대에서 가장 낮은 분진 농도를 나타내었으며, 환기횟수가 3 이상인 조건부터는 유량의 증가에 따른 공기 청정속도가 크게 감소함을 알 수 있다.
실시간 계측을 통한 버스 내외부의 미세먼지 농도 변화에 관한 연구
송해은(Hae-Eun Song),강율호(Yul-Ho Kang),우상무(Sang-Moo Woo),양수광(Su-Kwang Yang),진혁(Hyuk Jin),이형(Hyung Lee),안영철(Young-Chull Ahn) 대한설비공학회 2022 대한설비공학회 학술발표대회논문집 Vol.2022 No.6
미세먼지는 인체 건강에 직접 영향을 주며, 다양한 질병들을 일으키는 해로운 대기 오염물질이다. 2018 세계 공기질 보고서-지역 & 도시 PM2.5(초미세먼지)에 따르면, 우리나라의 초미세먼지 오염도는 칠레에 이어 경제협력개발기구(OECD) 회원국 중 2위로 나타났다. 대부분의 도시에서 많이 사용하고 있는 대중 교통 수단인 버스는 외부 영향과 승객의 수에 따라 오염도가 나타난다. 본 연구에서는 버스의 실내와 실외에 설치된 미세먼지 센서를 통해 버스의 내부와 외부에서의 미세먼지 특성을 분석하고자한다.
종합병원내 공기감염 예방을 위한 진료부와 로비공간의 기류 분석
송해은(Song, Hae-Eun),원안나(Won, An-Na),김성용(Kim, Seong-Yong),박진철(Park, Jin-Chul),황정하(Hwang, Jung-Ha) 한국건축친환경설비학회 2017 한국건축친환경설비학회 논문집 Vol.11 No.5
This study analyzes the types of space in the polyclinic and lobby spaces of hospitals, which are thought to be exposed to secondary airborne infections within hospitals. A hospital, which has space where the human traffic from the polyclinic overlaps with that of the lobby (space type II), was selected as the subject of this study. The air current distribution in the polyclinic and lobby areas are analyzed using the calculation program Star-ccm+. The air current distribution in the existing air-conditioned space is analyzed using T · A · B (Testing, Adjusting, Balancing) measured values. The result proved the possibility of secondary airborne infections caused by mixing of the air currents from the polyclinic and lobby in the upper and middle air layers. Five improvement suggestions in terms of changing the position of air inlets and outlets are proposed in this study. Among them, [ALT-3] the arrangement wherein outlets are placed on the first and third lines and inlets are placed on the second line is expected to significantly reduces the possibility of airborne infections, as the air currents in the lower, middle, and upper layers in the polyclinic and lobby spaces are not intermixed.
벨트의 가동에 의한 내부 유동을 고려한 석탄 분진 저감용 수분무 시스템에 관한 연구
강성호,송해은,안영철 한국동력기계공학회 2020 동력시스템공학회지 Vol.24 No.3
본 연구에서는 석탄 미세먼지가 발생되는 Conveyor 구간에 미세한 포그(Fine Fog)를 분사하여 석탄먼지와 분무 포그를 서로 부착 침강시키고자 할 때, 노즐의 위치와 각도에 따른 포그의 분포를 분석하고자 하였고, 또한 Conveyor의 이동으로 발생하는 내부 유동이 포그의 분포에 미치는 영향을 분석하여, Conveyor에 의한 유동을 고려한 노즐의 각도와 배치에 대한 연구를 수행하였다. 주요 연구결과는 다음과 같다. (1) Fog의 분사 각도는 공간내부가 아주 큰 경우 Fog 분포에 거의 영향을 주지 못함을 알 수 있다. (2) 컨베이어벨트가 가동되는 조건에서 발생하는 내부 유동은 Fog 입자가 균일하게 분포 하도록 강제한다. (3) 특히, 컨베이어 벨트 부근에 Fog 비율이 높을수록 유동에 의한 Fog의 분포 변화는 더욱 크게 발생한다. (4) 컨베이어벨트의 가동 유무에 따라 컨베이어벨트 부근에서의 Fog의 분포는 20% 이상 차이가 나기 때문에 Fog 입자를 원하는 곳에 분포시키기 위해서는 컨베이어벨트에 의해 발생 하는 유동을 고려한 설계가 필요하다. (5) Fog 입자를 통한 석탄 분진의 저감을 위해서는 분진이 발생하는 영역의 인근에 노즐을 위치시키거나 중력의 방향을 고려 할 필요가 있다.
공기청정기와 기류 제어용 FAN의 운전조건에 따른 교실 내 공기질 변화에 대한 해석적 연구
우상무,송해은,강율호,안영철 대한설비공학회 2023 설비공학 논문집 Vol.35 No.5
This study investigated the influence of the operating conditions on an air purifier and extra FAN efficiency in reducing particulate matter in a classrooms. Computational fluid dynamics (CFD) simulation considering three locations of Air purifiers and operating conditions of four FANs was conducted to evaluate the optimal operating condition. In this study, the Clean Air Delivery Rate (CADR) of Air purifier was 2.4 m3/min (161.4 CMH) and 4.8 m3/min(322.8 CMH). Assuming the indoor particulate concentration is 150 μg/m3, the performance of reducing particle concentration varies by a maximum of 31.2% depending on the position of the air purifier and the operating condition of the FAN. When the CADR of the air purifier is low, particulate matter reduction performance can be improved by a FAN. When using the FAN, make sure that it does not interfere with the airflow of the air purifier.