http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
손경민(Kyoungmin Son),임재관(Jaekwan Im),최재호(Jaeho Choi) 전력전자학회 2009 전력전자학술대회 논문집 Vol.2009 No.1
In Korean urban transit system, when the railcar starts, the electric power is absorbed from the line, and then the line voltage is instantaneously collapsed to provide a large accelerating torque. On the other hand, when the railcar brakes, the regenerative power is created and it increases the line voltage at the pantograph of the railcar. Therefor, by using the energy storage system near the train, the regenerated power can be saved to this system. The energy storage system is consisted of supercapacitor and a bidirectional DC-DC converter. In this paper, the control strategy of a bidirectional DC-DC converter is described to meet the performance for the initial charging mode and power control mode. From the simulation and experimental results, the validity of this energy storage system using supercapacitor is verified.
손경민(Kyoungmin Son),이진목(Jinmok Lee),노세진(Sejin Noh),최재호(Jaeho Choi) 전력전자학회 2008 전력전자학술대회 논문집 Vol.- No.-
This paper presents a PID controller and PI-PI dual loop controller for a single-phase inverter. The control parameters of conventional controllers are very difficult to make. But parameters of controllers based on pole-assignment are easy to make. Simulation results are presented for the system under R-L load, no load and change reference voltage.
극 배치 기법을 이용한 양방향 DC-DC 컨버터의 제어기 설계
노세진(Sejin Noh),손경민(Kyoungmin Son),최재호(Jaeho Choi) 전력전자학회 2008 전력전자학술대회 논문집 Vol.- No.-
In Korean urban transit system, when the railcar starts, the electric power is absorbed from the line, and then the line voltage is instantaneously collapsed to provide a large accelerating torque. On the other hand, when the railcar brakes, the regenerative power is created and it increases the line voltage at the pantograph of the railcar. Therefor, by using the energy storage system near the train, the regenerated power can be saved to this system. The energy storage system is consisted of supercapacitor and a bidirectional DC-DC converter. In this paper, controller design of a bidirectional DC-DC converter based on pole-assignment is proposed. This method can be easy to design controller. Simulation results by using the calculated parameters are presented.
슈퍼캐패시터 에너지 저장장치의 양방향 DC-DC 컨버터 제어기 설계
임재관(Jaekwan Im),손경민(Kyoungmin Son),권경민(Kyoungmin Kwon),최재호(Jaeho Choi),정교범(Gyo-Bum Chung) 전력전자학회 2009 전력전자학술대회 논문집 Vol.2009 No.2
본 논문은 차세대 에너지 저장장치로 각광받는 슈퍼커패시터를 이용한 양방향 DC-DC컨버터의 구성 및 빠른 동특성을 갖는 이중 루프 PI제어기 설계를 제시하였다. 제어기는 초기 슈퍼캐패시터의 충전을 위한 정전류 제어기와 초기 충전 이후에 동작을 개시하는 전력제어기를 구성하였다. 구성된 제어기는 PSIM을 이용한 시뮬레이션을 통하여 검증하였다.
이진목(Jinmok Lee),권경민(Kyoung-Min Kwon),손경민(Kyoungmin Son),최은진(Cui enzhen),임재관(Jaekwan Im),최재호(Jaeho Choi) 대한전기학회 2009 대한전기학회 학술대회 논문집 Vol.2009 No.7
본 논문에서는 단독부하형 삼상인버터의 디지털 전압제어기를 설계한다. 단독부하운전은 선형부하의 변동이나 비선형 부하에서도 안정적인 전압을 공급하는 것이 목적이다. 삼상 인버터를 선형 제어기로 제어하기 위해서 이상동기회전자표계로 제어하지만 두 개의 간섭항 때문에 MIMO 시스템으로 되어 해석적인 제어기를 설계하기 어려워 대부분의 연구에서는 시행착오법으로 제어기를 설계하였다. 본 논문에서는 삼상 인버터의 축변환시에 발생하는 간섭항의 영향을 상대이득행렬로 분석하여 간섭항의 영향을 분석하고 삼상 인버터 시스템을 SISO 시스템으로 만들어 전압제어기만을 갖는 최소 차수의 제어기를 해석적으로 설계하며 응답속도를 향상시키기위해서 오버슈트와 정정시간을 조절할 수 있는 극배치기법으로 설계한다. 설계한 제어기는 시뮬레이션과 실험을 통해서 강인성을 보인다.
시간응답을 고려한 삼상 DC/AC 인버터의 비간섭 제어기 설계
이진목(Jinmok Lee),박가우(Gawoo Park),이재문(Jaemoon Lee),손경민(Kyoungmin Son),Novie Ayub Windarko,민준기(Joon-ki Min),최재호(Jaeho Choi) 전력전자학회 2008 전력전자학술대회 논문집 Vol.- No.-
본 논문에서는 3상 VSI의 CVCF 제어를 위해 폐루프 비간섭 DQ 제어기 설계를 제안한다. DQ 제어기를 설계하기위해서 두 개의 간섭항을 폐루프 분리를 통하여 해석적인 PID 제어기를 설계한다. 제안한 PID 제어기는 시간응답을 만족하도록 설계하여 시뮬레이션을 통해 검증한다.