http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
이억섭,김선용,홍성경,Lee, O.S.,Kim, S.Y.,Hong, S.K. 한국정밀공학회 1995 한국정밀공학회지 Vol.12 No.12
This investigation evaluates dynamic fracture characteristics of two alloy steels (STD-11 and STS-3) and a gray cast iron (GC-30). The dynamic fracture toughness of crack initiation and some of the dynamic fracturing characteristics were evaluated by using the instrumented Charpy impact testing procedures. It was found from experimental results for three kinds of materials that inertia force is directly proportional to impact velocity. The duration time of inertia force was found to be constant regardless of impact velocities in steel specimens.
데이터 배선 용량 최소화를 위한 비정질 실리콘 박막 트렌지스터 배열의 최적화 설계와 구현
김창원,윤정기,김선용,김종효,Kim, C.W.,Yoon, J.K.,Kim, S.Y.,Kim, J.H. 대한의용생체공학회 2008 의공학회지 Vol.29 No.5
Thin-film transistor (TFT) arrays for an x-ray detector require quite different design concept from that of the conventional active-matrix liquid crystal devices (AM-LCDs). In this paper anew design of TFT array which uses only SiNx for passivation layer is described to meet the detector performance and the product availability simultaneously. For the purpose of optimizing the design parameters of the TFT array, a Spice simulation was performed. As a result, some parameters, such as the TFT width, the data line capacitance, and the storage capacitance, were able to be fixed. The other parameters were decided within a permissible range of the TFT process especially the photolithography process and the wet etch process. Then we adapted the TFT array which had been produced by the proposed design to our prototype model (FDXD-1417 and evaluated it clinically by comparing with a commercial model (EPEX, Hologic, Beford, USA). The results say that our prototype model is slightly better than EPEX system in chest PA images. So we can prove the technical usefulness and the commercial values of the proposed TFT design.
곽현덕(H. D. Kwak),전성민(S. M. Jeon),김진한(Jinhan Kim),조광래(G. R. Cho),김선용(S.Y. Kim),우관제(K. J. Woo) 한국트라이볼로지학회 2004 한국트라이볼로지학회 학술대회 Vol.38 No.-
In a turbopump cryogenic ball bearings are used to carry static and hydraulic loads, and these ball bearings must stand up to high load and speed in cryogenic circumstance. Verification of bearing performance is crucial to successful development of a turbopump. In this paper, focusing on the turbopump under developing by KARI, the performances of 203 and 207 bearings are verified through the series of tests simulating the real operating condition of turbopump.