http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
마이토마이신을 이용한 라섹 수술 후 지연성으로 발생한 비대 각막 반흔 2예
김동윤,김명준,윤삼영,신철진,김경훈,차흥원,Dong Yoon Kim,MD,Myoung Joon Kim,MD,PhD,Sam Young Yoon,MD,Chul Jin Shin,MD,Kyoung Hoon Kim,MD,Hungwon Tchah,MD,PhD 대한안과학회 2009 대한안과학회지 Vol.50 No.2
Purpose: To report late-onset hypertrophic corneal scars after laser epithelial keratomileusis (LASEK) with mitomycin C. Case summary: Case 1. A 34-year-old man who had undergone LASEK with mitomycin C 15 months prior was referred to our clinic because of corneal opacity of his right eye. After LASEK, there have been no abnormalities in either of his eyes. However, 11 monthsafter LASEK, he experienced decreased visual acuity in his right eye. The visual acuity was 0.03 in his right eye and 1.0 in his left eye. On slit lamp examination there was a whitish, hypertrophic scarin his right cornea. The lesion was located in the corneal center and the subepithelial space. Central corneal thickness was 828 μm. Case 2. A 23-year-old woman who had undergone LASEK with mitomycin C 14 months before was referred our clinic because of corneal opacity of her left eye. After LASEK, there had been no abnormalities in either of her eyes. However, 12 months after LASEK she experienced decreased visual acuity in her left eye. The visual acuity was 1.0 in her right eye and 0.2 in her left eye. On slit lamp examination there was a whitish, hypertrophic scar in her left cornea. Central corneal thickness was 794 μm. Conclusions: Manual debridement was performed to remove the hypertrophic scar in both cases. Case 1. After manual debridement, visual acuity of the right eye improved to 0.63. Case 2. After manual debridement, best-corrected visual acuity of the left eye was 0.63.
부분결합간섭계에 내장된 인공수정체 도수측정 공식들의 정확성 비교
김동윤,김명준,김재용,차흥원,Dong Yoon Kim,MD,Myoung Joon Kim,MD,PhD,Jae Yong Kim,MD,PhD,Hungwon Tchah,MD,PhD 대한안과학회 2009 대한안과학회지 Vol.50 No.4
Purpose: To evaluate the accuracy of various formulas installed in IOLMaster software which uses partial coherence interferometry for axial length measurement. Methods: This retrospective comparative study included 81 eyes of consecutive patients who had uneventful cataract surgery with implantation of Acrysof single piece (SA60AT) IOL. Axial length was measured with IOLMaster and IOL power was calculated using various formulas, including SRK II, SRK/T, Holladay 1, Haigis, and Hoffer Q. Subjects were stratified by axial length into Groups A (axial length < 23.50 mm), B (23.50 mm ≤ axial length < 25.00 mm), and C (axial length ≥ 25.00 mm). Target refractions of the five formulas were compared to the postoperative manifest refraction at 1 month. Results: The five formulas showed no difference in predicting postoperative refractive errors among all of the groups. Conclusions: Five formulas installed in IOLMaster software provided equivalent predictions of postoperative refractive error regardless of axial length. J Korean Ophthalmol Soc 2009;50(4):523-528
김동윤,Kim, Dong-Yun 한국방위산업진흥회 1997 國防과 技術 Vol.- No.221
지난호에 S-300V를 소개하면서 S-300 PMU-1 사진을 게재하여 이를 바로 잡습니다. S-300V는 이동형 대탄도탄 유도무기체계로 개발되었고 S-300 PMU-1은 원래 대항공기 방어를 주임무로 하는 드립니다. S-300 PMU 체계의 최신 개량형으로 서로 상이한 무기체계임을 알려드립니다. 아울러 패트리어트와 S-300V의 기사를 나누어 게재했으면 하는 의견이있어 이번호에는 패트리어트를 소개하고 8월호에 S-300V를 게재코자 합니다.
김동윤,Kim, Dong-Yun 한국방위산업진흥회 1997 國防과 技術 Vol.- No.220
요즈음 우리 대공방어 무기체계 구축에 논란이 되고 있는 미국의 패트리어트와 러시아의 S-300V에 대하여 이번과 다음호까지 2회에 걸쳐 게재한다. 상호 비교한다는 것이 불합리할지도 모르지만 기술적 측면을 살펴보면 도움이 되리라 생각한다.
김동윤,김상희,고보연,Kim Dong-Yun,Kim Sang-Hui,Go Bo-Yeon 한국국방경영분석학회 1991 한국국방경영분석학회지 Vol.17 No.1
In this paper, we deal with the TSP (Traveling Salesperson Problem) which is well-known as NP-complete optimization problem. the TSP is applicable to network routing. task allocation or scheduling. and VLSI wiring. Well known numerical methods such as Newton's Metheod. Gradient Method, Simplex Method can not be applicable to find Global Solution but the just give Local Minimum. Exhaustive search over all cyclic paths requires 1/2 (n-1) ! paths, so there is no computer to solve more than 15-cities. Heuristic algorithm. Simulated Annealing, Artificial Neural Net method can be used to get reasonable near-optimum with polynomial execution time on problem size. Therefore, we are able to select the fittest one according to the environment of problem domain. Three methods are simulated about symmetric TSP with 30 and 50-city samples and are compared by means of the quality of solution and the running time.