http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
역해석을 이용한 가열로 내 소재의 1차원 열유속 추정에 관한 연구
강덕홍,곽동성,김우승,이용국,Kang, Deok-Hong,Kwag, Dong-Seong,Kim, Woo-Seung,Lee, Yong-Kuk 대한기계학회 2003 大韓機械學會論文集B Vol.27 No.1
This study deals with the use of the conjugate gradient method for the simultaneous estimation of two unknown boundary heat fluxes on the slab in reheating furnace. Temperature measurements by the experiment are used in the inverse analysis. The heat flux estimations for three different cases of measurement locations in the slab are performed: non-skid, skid, and shift-skid zones. The estimated heat fluxes for three cases indicated the three regions having local peak values of heat fluxes. The estimated temperatures at measurement locations were in good agreements with the measured temperatures within 5% relative error.
강덕홍(Deok-Hong Kang),안예찬(Yeh-Chan Ahn),김종록(Jong-Rok Kim),오병도(Byung Do Oh),김무환(Moo Hwan Kim) 대한기계학회 2004 대한기계학회 춘추학술대회 Vol.2004 No.4
The transient nature and complex flow geometries of two-phase gas-liquid flows cause fundamental difficulties when measuring flow velocity using an electromagnetic flowmeter. Recently, a current-sensing flowmeter was introduced to obtain measurements with high temporal resolution (Ahn et al.). In this study, current-sensing flowmeter theory was applied to measure the fast velocity transients in slug flows. To do this, the velocity fields of axisymmetric gas-liquid slug flow in a vertical pipe were obtained using Volume-of-Fluid (VOF) method and the virtual potential distributions for the electrodes of finite size were also computed using the finite volume method for the simulated slug flow. The output signal prediction for slug flow was carried out from the velocity and virtual potential (or weight function) fields. The flowmeter was numerically calibrated to obtain the cross-sectional liquid mean velocity at an electrode plane from the predicted output signal. Two calibration parameters are required for this procedure: a flow pattern coefficient and a localization parameter. The flow pattern coefficient was defined by the ratio of the liquid resistance between the electrodes for two-phase flow with respect to that for single-phase flow, and the localization parameter was introduced to avoid errors in the flowmeter readings caused by liquid acceleration or deceleration around the electrodes. These parameters were also calculated from the computed velocity and virtual potential fields. The results can be used to obtain the liquid mean velocity from the slug flow signal measured by a current-sensing flowmeter.
강덕홍(Deok-Hong Kang),김성완(Seong-Hwan Kim),김기홍(Ki-Hong KIm) 대한기계학회 2007 대한기계학회 춘추학술대회 Vol.2007 No.5
In this study, the Peltier effect was applied to eliminate moistures in the air enclosed by a cabinet. We have developed the new electronic dehumidifier which has a new function of automatically evaporating the condensed water inner cabinet into the outside air. To obtain this function, the processes of dehumidification is that it condensed the moistures on the cold side heat sink and drained it into the hot side heat sink by the both gravitational and capillary forces and the droplets on the hot side heat sink surface was evaporated into the air outside the cabinet by the heat conducted through the hot side heat sink surface and the forced heat convection through the fan for cooling hot side heat sink. Compared to existing electronic dehumidifiers, this manufactured one showed a good performance that the electric power consumption for the same dehumidifying quantity was reduced by 50% compared with that of existing ones.