http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
ITGA1 polymorphisms and haplotypes are associated with gastric cancer risk in a Korean population.
Yim, Dong-Hyuk,Zhang, Yan-Wei,Eom, Sang-Yong,Moon, Sun In,Yun, Hyo-Yung,Song, Young-Jin,Youn, Sei-Jin,Hyun, Taisun,Park, Joo-Seung,Kim, Byung Sik,Lee, Jong-Young,Kim, Yong-Dae,Kim, Heon WJG Press 2013 World journal of gastroenterology Vol.19 No.35
<P>To evaluate the association between the genetic polymorphisms and haplotypes of the ITGA1 gene and the risk of gastric cancer.</P>
분자주형을 이용한 요중 1-hydroxypyrene의 측정 방법 개발
Dong-Hyuk Yim(임동혁),Sun-In Moon(문선인),Young-Sook Choi(최영숙),Heejin Park(박희진),Dae-Seon Kim(김대선),Seung-Do Yu(유승도),Chul-Ho Lee(이철호),Yong-Dae Kim(김용대),Heon Kim(김헌) 한국생명과학회 2011 생명과학회지 Vol.21 No.4
본 연구는 선행연구에서 molecular imprinting 방법을 이용하여 개발한 1-OHP 인식 TiO₂-Bead가 실제 소변중의 1-OHP를 효율적으로 검출할 수 있는지 평가하기 위해서 시행되었다. 본 연구에서 개발한 분석 방법은 within-day 변이계수가 4.97%, between-day 변이계수가 4.43%로 나타나 본 측정방법이 매우 안정적인 방법임을 확인할 수 있었다. 1-OHP와 유사한 물질들이 혼합된 용액으로부터 TiO₂-Bead-HPLC 측정방법의 회수율을 평가한 결과, 평균 105.6%의 회수율을 나타내었다. 실제 소변시료를 대상으로 기존의 효소-HPLC 측정방법과 본 측정방법 간의 상관성을 평가한 결과, 두 방법 간에는 높은 상관관계( r=0.74, p<0.01)를 보여 bead를 이용한 요중 1-OHP의 새로운 측정 방법의 유용성을 확인할 수 있었다. 본 연구에서 개발한 새로운 측정방법은 기존의 측정방법에 비해 요중 1-OHP 농도를 보다 간편하고 저렴한 가격으로 측정할 수 있다는 장점이 있다. 본 연구의 결과는 TiO2 코팅 bead를 응용한 요중 1-OHP 센서의 개발에 응용할 수 있을 것으로 생각되며, 분자주형을 이용한 bead의 개발은 1-OHP 이외의 다른 화학물질의 분석에도 다양하게 응용할 수 있을 것으로 기대된다. This study was performed to determine whether or not urinary 1-hydroxypyrene (1-OHP) levels can be accurately detected by our 1-OHP-detecting TiO2-Bead?HPLC assay that we developed based on the molecular imprinting method. Our method showed a variation coefficient of 4.97% and a between-day variation coefficient of 4.43%, suggesting that this may be a very stable method. In addition, the recovery rate of 1-OHP from a mixture of 1-OHP and similar substances using our TiO2-Bead-HPLC method was estimated to be 105.6%. The correlation coefficient between the conventional enzyme-HPLC method and this new method was 0.74 (p<0.01) when the urine samples were tested. Based on this result, it is conceivable that our method could be a useful technique for measuring urinary 1-OHP levels. Moreover, our method has some advantages of being easier and less expensive than the conventional method. The results of this study suggest that our method can facilitate the development of a urine 1-OHP sensor using TiO₂-coating beads and that development of beads by molecular imprinting can be applied to analysis of chemicals other than 1-OHP.
Polarized Terahertz Waves Emitted from In0.2Ga0.8As Nanowires.
Yim, Jong-Hyuk,Irfan, Muhammad,Song, Kyoung-Jin,Lee, Eun-Hye,Song, Jin-Dong,Jho, Young-Dahl American Scientific Publishers 2015 Journal of nanoscience and nanotechnology Vol.15 No.8
<P>We investigate the polarizability of terahertz (THz) waves emitted from undoped In0.2Ga0.8As nanowires (NWs). THz emission amplitude shows strong enhancement in vertically aligned NWs compared to less-aligned NWs. In particular, polarized THz waves are clearly demonstrated in aligned NWs via a drastic variation of amplitudes as a function of the axis angle in polarization-sensitive photoconductive antenna. In addition, phase reversal between aligned and less-aligned NWs substantiates the geometrical dependence of electronic diffusion in generating the transient THz electric fields.</P>
Trace Organic Contaminants in Sediments from Deep-sea Basin near Dokdo, Korea
Yim, Un-Hyuk,Oh, Jae-Ryoung,Hong, Sang-Hee,Li, Dong-Hao,Shim, Won-Joon,Choi, Hye-Kyung,Kim, Eun-Soo,Shim, Jae-Hyung Korea Institute of Ocean ScienceTechnology 2002 Ocean and Polar Research Vol.24 No.4
Trace organic contaminants in deep-sea sediments near Dokdo were analyzed. Total PAMs concentration ranged 14.8-314 ng/g dry weight and high molecular weight PAHs were dominant. The highest PAHs concentration was detected at A19 which located at Ulleung Basin. Most of organochlorines were under detection limit. Among the detected organochlorines, DDT compounds were dominant and followed by HCHs and HCB. Butyltin compounds and most of organophosphorus pesticides were not detected. Vertical distribution of PAHs showed typical sub-surface maximum and decreasing trends depending on depth. The highest PAHs concentration reached 454ng/g. Some organochlorines, DDT, HCH was detected and also showed decreasing trends. Other target organic pollutants were not detected in core sediments. Abnormally high level of PAHs concentration in A19 was discussed and the input sources were inferred to be the transport of sludge derived pollutant dumped at dumping site 'Byung' by deep current.
( Dong Jin Kim ),( Hyun Seok Kang ),( Hyuk Soon Choi ),( Hye Jin Cho ),( Eun Sun Kim ),( Bo Ra Keum ),( Hyong Gin An ),( Ji Hoon Kim ),( Yeon Seok Seo ),( Yong Sik Kim ),( Hyung Joon Yim ),( Yoon Tae 대한간학회 2011 Clinical and Molecular Hepatology(대한간학회지) Vol.17 No.2
Background/Aims: Several studies suggested that serum cystatin C (CysC) is more useful than serum creatinine (Cr) for the assessment of renal function in patients with liver cirrhosis. This study evaluated the clinical significance of CysC in patients with cirrhotic ascites and normal Cr level. Methods: We enrolled patients with cirrhotic ascites and a normal serum Cr level (<1.2 mg/dL). GFR was measured by 99mTc-DTPA renal scan. Serum Cr, CysC, and Cr clearance (CCr) were measured on the same day. Significant renal impairment and severe renal impairment were defined as GFR <60 mL/min and GFR <30 mL/min, respectively. Results: Eighty-nine patients with cirrhotic ascites were enrolled in the study (63 men and 26 women; age, 55±11 years). Forty-seven (52.8%) and 42 (47.2%) patients were in Child-Pugh grade B and C, respectively. Serum Cr and CysC levels and GFR were 0.8±0.2 mg/dL, 1.1±0.3 mg/L, and 73.4±25.5 mL/min, respectively. Significant and severe renal impairment were noted in 28 (31.5%) and 2 (2.2%) patients, respectively. GFR was well correlated with serum Cr, CysC, and e-GFRMDRD, while it was not correlated with e-GFRC&G. In multivariate analysis, only CysC was significantly correlated with GFR (β, 45.620; 95% CI, 23.042-68.198; P<0.001). Serum CysC level was the only independent predictor for significant renal impairment. Conclusions: Significant renal dysfunction was not rare in patients with cirrhotic ascites, even their serum Cr level is normal. Serum CysC is a useful marker for detecting significant renal dysfunction in these patients.
다양한 낙농 발효유제품에서 HPLC를 이용하여 탄수화물과 유기산의 동시 검출에 관한 연구
김동현 ( Dong Hyeon Kim ),황대근 ( Dae Geun Hwang ),천정환 ( Jung Whan Chon ),김현숙 ( Hyunsook Kim ),김홍석 ( Hong Seok Kim ),송광영 ( Kwang Young Song ),임진혁 ( Jin Hyuk Yim ),김영지 ( Young Ji Kim ),강일병 ( Il Byung Kang ) 한국유가공기술과학회 2015 Journal of Dairy Science and Biotechnology (JMSB) Vol.33 No.4
본 연구에서는 다양한 낙농 발효유제품에 있어서 다양한 유기산과 탄수화물의 분석이 HPLC 방법으로 동시에 잘 진행되었다. 이 방법의 주요 장점으로는 (1) 간단한 시료 준비와 단일 추출이 가능, (2) 유동상(mobile phase)과 추출 용매에 있어서 편리성과 경제성, (3) 추출제와 유동상에 사용되는 황산의 농도가 매우 낮기에 친환경적인 실험, (4) 하나의 샘플당 30분 안에 HPLC의 분석이 완료 가능, (5) 다양한 농도 범위에서도 분석 및 정량 가능, (6) 몇 가지 물질을 제외하고 모든 화합물의 변동계수가 낮음, 그리고 (7) 회수율이 대체적으로 높다는 것이다. 또한, 60~65℃에서 분석 column을 사용하였기에 column 효율면에서도 손실이 극히 적은 것으로 관찰되었다. 따라서 본 실험에서 분석된 다양한 낙농 발효유제품에서의 acid, 탄수화물, diacetyl, acetoin 등이 HPLC 방법은 매우 신속하고 정확하게 검출되었다. 하지만 다양한 향미의 변화를 최소화하면서 다양한 향미를 효과적으로 추출할 수 있는 HPLC 방법들이 지속적으로 개발되어야 다양한 낙농 발효유제품의 품질개선에 기여할 것으로 사료된다. 왜냐하면 향미 성분의 분석은 성분을 정성하는 것뿐만 아니라, 정성된 화합물이 그 식품의 향에 어느 정도 기여하는지를 중요하게 결정하기 때문이다. 또한 본 실험에 사용된 HPLC 방법으로 다양한 유산균주의 일정한 배양시간동안 유당분해효소(lactase) 능력이 조사 되었는데, 각 Probiotic lactic acid bacteria마다 다양한 유당분해효소(lactase)의 능력을 보였으며, 같은 균종에서도 차이가 있는 것으로 나타났다. 본 실험에서는 Bifidobacterium spp.가 Lactobacillus spp.와 Streptococcus spp.보다 높은 유당분해효소(lactase)의 능력을 보였다. 하지만 유산균주의 유당분해효소 능력을 정확하게 파악하기 위해서는 각 Probiotic lactic acid bacteria의 exo- 및 endo-lactase에 대한 연구가 추가적으로 필요하다. 결론적으로 다양한 낙농발효식품 및 기타 발효식품 등에서 HPLC 방법으로 동시에 유기산과 탄수화물 분석이 공인방법으로써 인정되기 위해서는 더 많은 기초자료 확립과 재현성에 관한 지속적인 연구가 진행되어야 할 것으로 사료된다. Various carbohydrates (lactose, glucose, and fructose), lactic acid, uric acid, and acetoin were separated on a ZORBAX Carbohydrate Analysis column using the Agilent 1200 HPLC ChemStationTM, and were identified according to retention times with 325 Dual Wavelength UV-Vis Detector and Refractive Index Detector with 0.013 N H2SO4 at a flow rate of 0.8 mL/min. In addition, the lactase activity of four commercial probiotic lactic acid bacteria during 6-hour incubation was determined using a high-performance liquid chromatography (HPLC) method. Among the tested samples, Bifidobacterium animalis subsp. lactis showed the greatest lactase activity, followed by Lactobacillus rhamnosus and Lactobacillus casei, with Streptococcus salivarius subsp. thermophilus showing the lowest activity. Therefore, this HPLC technique shows potential for evaluating the fermentation processes of probiotic lactic acid bacteria and could simultaneously confirm the degree of ripening in various fermented dairy foods within only a half hour.