http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Amperometric Determination of Nitrite at Poly(Methylene Blue)-Modified Glassy Carbon Electrode
Guang-Ri Xu,Guifang Xu,Ming-Lu Xu,Zhengqing Zhang,Yuan Tian,최한님,이원용 대한화학회 2012 Bulletin of the Korean Chemical Society Vol.33 No.2
Electrochemical characteristics of nitrite ion were investigated at a poly(methylene blue)-modified glassy carbon electrode by cyclic voltammetry and differential pulse voltammetry. The poly(methylene blue)-modified glassy carbon electrode exhibited enhanced anodic signals for nitrite. The effects of key parameters on the detection of nitrite were evaluated at the modified electrode, such as pH, accumulation time, and scan rate. Under optimum condition, the chemically modified electrode can detect nitrite in the concentration range 2.0 × 10−6 to 5.0 × 10−4 M with the detection limit of 2.0 × 10−6 M and a correlation coefficient of 0.999. The detection of nitrite using the chemically modified electrode was not affected by common ions such as Na+, K+,Ca2+, Cl−, HPO42− and H2PO4−. The modified electrode showed good stability and reproducibility. The practical application of the present method was successfully applied to the determination of nitrite ion in cabbage samples.
Surgical treatment for hepatocellular carcinoma with bile duct invasion
Xu-guang Hu,Wei Mao,Sung Yeon Hong,Bong-Wan Kim,Wei-guang Xu,Hee-Jung Wang 대한외과학회 2016 Annals of Surgical Treatment and Research(ASRT) Vol.90 No.3
Purpose: There is still some debate on surgical procedures for hepatocellular carcinoma (HCC) patients with bile duct tumor thrombi (BDTT, Ueda type 3 or 4). What is adequate extent of liver resection for curative treatment? Is extrahepatic bile duct resection mandatory for cure? The aim of this study is to answer these questions. Methods: Between February 1994 and December 2012, 877 consecutive HCC patients underwent hepatic resection at Ajou University Hospital. Thirty HCC patients (3.4%) with BDTT (Ueda type 3 or 4) were retrospective reviewed in this study. Results: In total, 20 patients enrolled in this study were divided into 2 groups: patients who underwent hemihepatectomy with extrahepatic bile duct resection (group 1, n = 10) and with only removal of BDTT (group 2, n = 10). The 1-, 3- and 5-year overall survival rates were 75.0%, 50.0%, and 27.8%, respectively. The 1-, 3-, and 5-year survival rates of group 1 were 100.0%, 80.0%, and 45.7%, and those of group 2 were 50.0%, 20.0%, and 10.0%, respectively (P = 0.014). The 1-, 3-, and 5-year recurrences free survival rates of group 1 were 90.0%, 70.0%, and 42.0%, and those of group 2 were 36.0%, 36.0%, and 0%, respectively (P = 0.014). Thrombectomy and infiltrative growth type (Ig) were found as independent prognostic factors for recurrence free survival by multivariate analysis. Thrombectomy, Ig, and high indocyanine green retention rate at 15 minutes were found as independent prognostic factors for overall survival by multivariate analysis. Conclusion: We suggest that the appropriate surgical procedure for icteric HCC patients should be comprised of ipsilateral hemihepatectomy with caudate lobectomy and extrahepatic bile duct resection.
Amperometric Determination of Nitrite at Poly(Methylene Blue)-Modified Glassy Carbon Electrode
Xu, Guang-Ri,Xu, Guifang,Xu, Ming-Lu,Zhang, Zhengqing,Tian, Yuan,Choi, Han-Nim,Lee, Won-Yong Korean Chemical Society 2012 Bulletin of the Korean Chemical Society Vol.33 No.2
Electrochemical characteristics of nitrite ion were investigated at a poly(methylene blue)-modified glassy carbon electrode by cyclic voltammetry and differential pulse voltammetry. The poly(methylene blue)-modified glassy carbon electrode exhibited enhanced anodic signals for nitrite. The effects of key parameters on the detection of nitrite were evaluated at the modified electrode, such as pH, accumulation time, and scan rate. Under optimum condition, the chemically modified electrode can detect nitrite in the concentration range $2.0{\times}10^{-6}$ to $5.0{\times}10^{-4}$ M with the detection limit of $2.0{\times}10^{-6}$ M and a correlation coefficient of 0.999. The detection of nitrite using the chemically modified electrode was not affected by common ions such as $Na^+$, $K^+$, $Ca^{2+}$, $Cl^-$, $HPO_4^{2-}$ and $H_2PO_4^- $. The modified electrode showed good stability and reproducibility. The practical application of the present method was successfully applied to the determination of nitrite ion in cabbage samples.
Lu Xu,Chun-Qing Zhao,De-Jin Xu,Guang-Chun Xu,Xiao-Long Xu,Zhao-Jun Han,Ya-Nan Zhang,Zhong-Yan Gu 한국응용곤충학회 2017 Journal of Asia-Pacific Entomology Vol.20 No.2
Nuclear receptors (NRs), which belong to a superfamily of ligand-dependent transcription factors, play essential roles in gene regulation to affect numerous physiological pathways. Twenty NR genes were identified in Nilaparvata lugens by using genomic, transcriptomic and GenBank databases, and categorized into NR0-NR6 subfamilies according to standard nomenclature. Among them, three NR geneswere classed into NR0, four into NR1, eight into NR2, one into NR3, one into NR4, two into NR5, and one into NR6, respectively. A phylogenetic tree of NRs from N. lugens and other representative species was constructed, which provided evolutionary insight into genetic distance. In order to investigate the NRs,whichwere induced by sulfoxaflor, time- and tissue-specific expression profiles of NR genes in fourth-instar nymphs were determined following LD50 sulfoxaflor treatment (0.28 ng/insect) and compared with control samples. NlUSP, NlE78, NlTLL, NlHR51, NlHR83, NlPNR and NlFTZ-F1 were highly expressed following 12–48 h of sulfoxaflor treatment. NlHR39 and NlDSF transcripts were detected in the head and the thorax, respectively. High-level and constitutive expression of NlHR3, NlTLL, NlHR83, NlFTZF1 and NlHR4 were found in the abdomen. Feeding of dsRNAs reduced the expression of NlHR3, NlUSP, NlTLL, NlHR83, NlPNR, NlFTZ-F1 and NlHR4 (35.48–49.77%) and caused significant nymph mortality (69.21–81.45%). These NRs, considered as insecticide targets, may play important function in sulfoxaflor detoxification.
Selective Determination of Quercetin Using Carbon Nanotube-Modified Electrodes
Xu, Guang-Ri,Kim, Sunghyun WILEY-VCH Verlag 2006 Electroanalysis Vol.18 No.18
<P>Electrochemical detection of quercetin has been carried out on glassy carbon electrodes modified with carbon nanotubes and Nafion (GC/Nafion-CNT). GC/Nafion-CNT electrodes did not show passivation effect that occurs on the unmodified electrodes and displayed better stability and reproducibility. Quercetin oxidation was most favorable in acidic conditions and current gradually decreased as the solution pH increased. No oxidation was observed when two &n.bond;OH groups in a catechol moiety were fully deprotonated. These electrodes enabled selective determination of quercetin in the presence of interfering species such as ascorbic acid, uric acid, glucose, and catechol in large excess. Quantification of quercetin in a yellow onion has been made and favorably compared with reported values. Good selectivity and high sensitivity obtained by Osteryoung sSquare-wave voltammetry can open new possibilities of direct quercetin determination in vegetables with a minimal sample treatment.</P>
Xu, Guang-Ri,Qi, Xin-hua,Yang, Fengxia,Lee, Jae-Joon,Xu, Ming-Lu,Zhang, Yu-Ping,Kim, Sunghyun WILEY-VCH Verlag 2009 Electroanalysis Vol.21 No.22
<P>A glassy carbon electrode having two polymer layers has been applied to selectively detect epinephrine. The inner layer formed by electropolymerization of macrocyclic nickel complex functioned as an electrocatalyst for epinephrine oxidation and the outer layer composed of hydrolyzed polyurethane γ-benzyl L-glutamate as a screening layer. Differential pulse voltammetry showed almost 100% recovery of epinephrine even in 100-fold excess of interferents. When applied to a dual glassy carbon electrode as an amperometric detector in flow injection analysis, a linear response over 0.1 μM and 10 μM was obtained. Recovery tested for 5-fold diluted human urine samples was 97.5%.</P>
Study on Efficiency Optimizing of PMSM for Pump Applications
Guang-xu Zhou,Hui-jun Wang,Dong-Hee Lee,Jin-Woo Ahn 전력전자학회 2007 ICPE(ISPE)논문집 Vol.- No.-
In view of the operation characteristics of pump application, pump system should have high efficiency and energy saving during the whole operating process. A novel efficiency-optimization control strategy is presented to meet the demand of high efficiency of variable speed high efficiency PMSM. The core of this strategy is the excellent integration of mended maximum torque to current control algorithm, which is based on the losses model during the dynamic and the grade search method with changed step by fuzzy logic during the steady. A TMS320LF2407A DSP-based digital control inverter for variable speed high efficiency PMSM is developed. The performance experiments for control system of variable speed high efficiency PMSM have been completed. The tested result verified that the system can reliably operate with the different control strategy during the dynamic and steady operation, and the system has more perfect performances using the efficiency-optimization control.