      • 비정질 평판형 측정기를 이용한 디지털 방사선 영상의 특징

        정회원,김정민,정만희,임은경,Jeong, Hoi-Woun,Kim, Jung-Min,Jeong, Man-Hee,Im, Eun-Kyung 대한디지털의료영상학회 2006 대한디지털의료영상학회논문지 Vol.8 No.1

        The rapid development in digital acquisition technology in radiography has not been accompanied by information regarding optimum radiolographic technique for use with an amorphus silicon flat panel detector. The purpose of our study was to compared imaging characteristics and image quality of an amorphus silicon flat panel detectors for digital chest radiography. All examinations were performed by using an amorphus silicon flat panel detector. Chest radiographs of an chest phantom were obtained with peak kilovoltage values of 60$\sim$150 kVp. Published data ell the effect of x-ray beam energy on imaging characteristics and image qualify when using an amorphus silicon flat panel detector. It is important that radiographers are aware of optimum kVp selection for an amorphus silicon flat panel detector system, particularly for the commonly performed chest examination.

      • KCI등재

        인체 흉부 모형 팬텀을 이용한 컴퓨터방사선영상에서 노출지수의 적용 사례 연구

        정회원,민정환,Jeong, Hoi-Woun,Min, Jung-Whan 대한방사선과학회 2018 방사선기술과학 Vol.41 No.6

        As the use of digital radiographic system has been expanded, there are some concerns an increase about in patient of radiation dose. Therefore, International Electro-technical Commission (IEC) has been proposed a standard foe exposure index (EI). In this study, the EI was measured on human chest model using computed radiography (CR). Radiation quality used RQA5 of IEC62494-1. After acquiring the chest anterior posterior image (Chest AP) by using the phantom, the EI was obtained by applying the system response. In this study, we have analyzed the images with the detector size (Full filed ROI) and the optimized image (Fit filed ROI). The EI increased proportionally with radiation dose increase. Due to the discrete increase in pixel value, the EI showed an exponential increase. The discrete increase in noise equivalent quanta (NEQ) resulted in a discrete increase in the EI. The EI of the two images used in this study increased with increasing NEQ but showed different increments. For the measurement of the EI, IEC standards must be followed. The EI should be used as an index to evaluate the image quality for quality control of X-ray image rather than as an indicator of exposure dose. When calculating the EI, the system response should be applied depending on whether or not the grid is used. The size of the field should be obtained by including only the necessary parts.

      • KCI등재

        CsI(TI) Indirect Flat Panel Detector의 선질에 따른 물리적 영상 평가

        정회원(Hoi-Woun Jeong),민정환(Jung-Hwan Min),김정민(Jung-Min Kim),박민석(Min-Seok Park),이광용(Gaung-Young Lee) 대한방사선과학회 2012 방사선기술과학 Vol.35 No.2

        간접형 CsI flat-panel detector (FPD)의 해상특성(modulation transfer function, MTF), 잡음특성(Wiener spectrum or noise power spectrum, NPS), 양자검출효율(detective quantum efficiency, DQE)을 측정하고 평가하기 위하여 본 실험을 실시하였다. IEC에서 권고한 실험방법을 따라 RQA3, RQA5, RQA7, RQA9의 방사선 선질을 사용하였다. MTF는 egde법을 사용하였다. Wiener spectrum은 조사 영역내에서 획득한 영상의 푸리에 변화를 통하여 구하였다. DQE는 MTF, WS(NPS), X선 입력 및 입력 광자량을 사용하여 평가하였다. 특성곡선은 RQA3와 RQA5, RQA7, RQA9과는 차이가 발생하였다. MTF는 X선 선질과는 상관없이 일정하였다. WS(NPS)은 X선 양이 증가 할수록 감소하였으며, RQA3, RQA5, RQA7, RQA9순으로 감소하였다. DQE는 1mR에서 가장 우수했으며, RQA3, RQA5, RQA7, RQA9순으로 감소하였다. FPD의 물리적 영상 특성을 입력 선질에 따라 다를 수 있다. 본 연구를 통하여 디지털 방사선 시스템의 바르게 사용하려면 FPD의 물리적 영상 특성을 아는 것이 중요함을 인식하게 되었다. The purpose of this work was to evaluate an amorphous silicon cesium iodide based indirect flat-panel detector (FPD) in terms of their modulation transfer function (MTF), Wiener spectrum (WS, or noise power spectrum, NPS), and detective quantum efficiency (DQE). Measurements were made on flat-panel detector using the International Electrotechnical Commission (IEC) defined RQA3, RQA5, RQA7, and RQA9 radiographic technique. The MTFs of the systems were measured using an edge method. The WS(NPS) of the systems were determined for a range of exposure levels by two-dimensional (2D). Fourier analysis of uniformly exposed radiographs. The DQEs were assessed from the measured MTF, WS(NPS), exposure, and estimated ideal signal-to-noise ratios. Characteristic curve in the RQA3 showed difference in the characteristic curve from RQA5, RQA7, RQA9. MTFs were not differences according to x-ray beam quality. WS(NPS) was reduced with increasing dose, and RQA 3, RQA5, RQA7, RQA9 as the order is reduced. DQE represented the best in the 1mR, RQA 3, RQA5, RQA7, RQA9 decrease in the order. The physical imaging characteristics of FPD may also differ from input beam quality. This study gives an initial motivation that the physical imaging characteristics of FPD is an important issue for the right use of digital radiography system.

      • SCOPUSKCI등재
      • 바텀애시를 혼입한 고강도 콘크리트의 강도 특성

        정회원 ( Jung Hoe-won ),정승태 ( Jeong Seung-tae ),부이광테 ( Bui Quang The ),양인환 ( Yang In-hwan ) 한국구조물진단유지관리공학회 2020 한국구조물진단유지관리공학회 학술발표대회 논문집 Vol.24 No.1

        본 연구는 콘크리트의 잔골재를 대체하여 바텀애시를 혼입한 고강도 콘크리트 특성에 관한 연구를 수행하였다. 바텀애시 혼입률에 따른 특성을 파악하기 위하여 바텀애시 치환율 0%, 25%, 50%, 75% 및 100%로 설정하였으며, 포졸란 재료인 바텀애시의 영향을 분석하기 위하여 28일 및 56일 양생을 실시하였다. 이후, 물리적 특성인 단위중량 및 초음파속도를 측정하였으며, 역학적 특성인 압축강도, 쪼갬인장강도 및 휨인장강도 실험을 수행하였다.

      • KCI등재

        다양한 디지털 방사선 시스템의 물리적 영상 특성 조사

        정회원(Hoi-Woun Jeong),민정환(Jung-Hwan Min),윤용수(Yong-Su Yoon),김정민(Jung-Min Kim) 대한방사선과학회(구 대한방사선기술학회) 2017 방사선기술과학 Vol.40 No.3

        본 연구는 전하결합소자(charged coupled device; CCD), CR (computed radiography), 평판형검출기(flat panel detector; FPD) 등을 사용하는 다양한 디지털 방사선(digital radiography; DR) 시스템의 물리적 영상 특성의 평가를 실시한 것이다. 본 연구에서 적용된 영상 특성은 신호응답특성(system response), 해상력특성(modulation transfer function;MTF), 잡음특성(wiener spectrum; WS), 양자검출효율(detective quantum efficiency; DQE) 등이며 이를 통하여 DR 시스템의 성능을 비교하였다. CCD의 신호응답특성은 입사선량에 비례하여 증가하였으며, CR과 FPD는 입사선량의 증가에 대수적 비례 관계를 보이면서 증가하였다. MTF는 CR과 FPD는 유사한 경향을 나타내었지만 CCD는 떨어지는 값을 나타내었다. WS는 FPD가 가장 낮았고, CR, CCD 순으로 증가하였다. DQE는 FPD, CR, CCD의 순으로 나타났다. DR 시스템은 영상수용체의 종류에 따라 서로 다른 영상 특성이 나타났다. 의료영상 획득 시 DR 시스템을 올바르게 사용하려면 영상의 물리적 특성을 정확히 알고 사용하는 것이 중요하다. We aimed to evaluate the physical imaging properties in various digital radiography systems with charg-ed coupled device (CCD), computed radiography (CR), and indirect flat panel detector (FPD). The imaging properties measured in this study were modulation transfer function (MTF) wiener spec-trum (WS), and detective quantum efficiency (DQE) to compare the performance of each digital radiog-raphy system. The system response of CCD were in a linear relationship with exposure and that of CR and FPD were proportional to the logarithm of exposure. The MTF of both CR and FPD indicated a similar tendency but in case of CCD, it showed lower MTF than that of CR and FPD. FPD showed the lowest WS and also indicated the highest DQE among three systems. According to the results, digital radiography system with different type of image receptor had its own image characteristics. Therefore, it is important to know the physical imaging characteristics of the digital radiography system accurately to obtain proper image quality.

      • KCI등재

        침심 노즐전극의 전기유체역학적 펌핑 특성

        鄭會元(Hoi-Won Jung),文在德(Jae-Duk Moon) 대한전기학회 2008 전기학회논문지 Vol.57 No.10

        A cooling system for microelectronics is becoming more important as its surface heat density is projected to reach that of the sun surface. The existing technologies using natural and forced convection are limited to solve the problems, Recently, an electrohydrodynamic driven flow is studied as one of the means to cope with this problems. A new method, utilizing a needle-centered nozzle electrode, has been proposed and investigated. The I-V characteristics of the nozzle electrode for deionized water and silicone oil were significantly different from that of without liquid, which might be due to the liquid drop covered on the nozzle tip by the EHD force acting near the needle tip. Results showed that the liquid pumping rate and flow efficiency of the nozzle electrode were very high, especially for the silicone oil. Theoretical analysis also showed the effectiveness of the needle electrode centered in the ceramic nozzle, which, however, can be a means as a liquid pump.

      • KCI등재

        디지털 방사선 시스템에서 발생하는 Artifact

        민정환(Jung Whan Min),김정민(Jung Min Kim),정회원(Hoi Woun Jeong) 대한방사선과학회(구 대한방사선기술학회) 2015 방사선기술과학 Vol.38 No.4

        디지털 방사선 시스템은 영상의학에서 큰 비중을 차지하고 있다. 잘못된 영상이 제공 된다면 이는 환자의 건강에 나쁜 영향을 줄 수 있기에, 올바른 디지털 방사선 영상이 제공되어야만 한다. 또한, artifact는 오진으로 이어질 수 있다. 디지털 방사선 시스템에서 발생하는 artifact를 종류별로 분석하여 그 결과 분석하였다. 본 연구에서 사용된 artifact는 서울의 종합병원 급 의료기관에서 2007년부터 2014년까지 수집된 자료들이다. 수집된 자료는 발생 원인별로 구별하여 그 원인을 분석하였다. artifact는 하드웨어적 artifact, 소프트웨어적 artifact, 사용자 오류, 시스템 artifact 및 기타로 구분하였다. 하드웨어적 artifact는 Ghost가 가장 빈번하게 관찰되었으며, 이는 신호의 잔류에 의한 것이다. 다음은 RF 잡음에 의한 오류, 장비 내 이물질에 의한 오류 순이다. 소프트웨어 artifact는 많은 원인이 있다. 부정확한 영상 교정에 의한 artifact가 가장 많았으며, EDR 인식오류, 접합면 처리 오류 등이 있으며, 소프트웨어 artifact는 매우 다양한 경향을 나타낸다. 사용자 오류는 디지털 의료 영상 시스템을 바르게 이해하지 못해 발생시킨 것들이 많았다. 아울러, 시스템 artifact는 DICOM 헤더 정보 오류, 압축 오류가 있다. 분명하게 나타나는 artifact는 재촬영의 원인이 되어 환자의 피폭을 증가시키고, 불분명하게 나타나는 artifact는 오진을 유발 시킬 수 있다. 따라서 방사선사에게서 이러한 artifact를 바로 구별 할 수 있는 능력이 요구 된다. 그러므로 artifact가 발생되는 원인과 그 특성을 분명하게 이해함으로 지속적인 교육과 안정적인 시스템 운영에 힘써야 할 것으로 사료된다. Digital Radiography is a big part of diagnostic radiology. Because uncorrected digital radiography image supported false effect of Patient's health care. We must be manage the correct digital radiography image. Thus, the artifact images can have effect to make a wrong diagnosis. We report types of occurrence by analyzing the artifacts that occurs in digital radiography system. We had collected the artifacts occurred in digital radiography system of general hospital from 2007 to 2014. The collected data had analyzed and then had categorize as the occurred causes. The artifacts could be categorized by hardware artifacts, software artifacts, operating errors, system artifacts, and others. Hardware artifact from a Ghost artifact that is caused by lag effect occurred most frequently. The others cases are the artifacts caused by RF noise and foreign body in equipments. Software artifacts are many different types of reasons. The uncorrected processing artifacts and the image processing error artifacts oc-curred most frequently. Exposure data recognize (EDR) error artifacts, the processing error of commissural line, and etc., the software artifacts were caused by various reasons. Operating artifacts were caused when the user didn't have the full understanding of the digital medical image system. System artifacts had ap-peared the error due to DICOM header information and the compression algorithm. The obvious artifacts should be re-examined, and it could result in increasing the exposure dose of the patient. The unclear artifact leads to a wrong diagnosis and added examination. The ability to correctly determine artifact are required. We have to reduce the artifact occurrences by understanding its character-istic and providing sustainable education as well as the maintenance of the equipments.

      • KCI등재

        Regius 150 Computed Radiography 시스템의 Noise 평가에 관한 연구

        김정민(Jung-Min Kim),민정환(Jung-Whan Min),정회원(Hea-Won Jeong),임은경(Eun-Kyung Im),양한준(Han-Joon Yang) 대한방사선과학회(구 대한방사선기술학회) 2006 방사선기술과학 Vol.29 No.4

          CR 시스템의 잡음(Noise)의 주요한 원인은 X-선 양자 모틀이며 그 외에 Imaging plate의 구조 노이즈, 휘진발광체의 광양자 노이즈, 전기계의 노이즈, 양자화 노이즈 등이 있다.<BR>  Regius 150시스템에서 선량이 0.1mR~100mR까지 변화할 때 SNR 변화는 0.1mR에서 8.2부터 선형성을 가지고 증가하고 있다. 이때 최저 SNR 값이 5 이상 되므로 충분한 신뢰성을 확보했다고 할 수 있다.<BR>  의료영상시스템의 가장 일반적인 노이즈 평가방법인 Noise Power Spectrum(NPS)을 이산적 화상데이터로부터 얻어진 Pixel 값의 요동으로부터 직접 푸리에 변환하여 구하였다. 주파수 0.5lp/㎜~2.5lp/㎜ 구간의 NPS은 선량이 많아질수록 개선되며 1mR 조사 시 10?⁴~10?? 사이에 분포하여, 시판되고 있는 타 회사의 CR시스템과 유사한 노이즈 특성을 가지고 있다.   The Noise of CR Systems is made up of X-ray quantum mottle and additional Imaging plate"s structure noise, photon noise of lumine cence, noise of electrometer, quantization noise etc.<BR>  In this Regius 150 system, SNR was increased from 8.2 to 30 with linearily according to radiation dose from 0.1mR to 100mR. It means that the Regius 150 system has enough trustability because of SNR is over 5 by Rose Model.<BR>  NPS was calculated two dementional Fourier Tranform with shake of pixel value in the white Image.<BR>  In the spatial frequence range of 0.5lp/㎜~2.5lp/㎜, the NPS was distributed 10?⁴~10?? at 1mR X-ray dose.<BR>  That is similar result compare other systems to that of Kodak CR system reported by Carlu, HR-CR system reported by Dobbins.