RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • 신경근전기자극에 의한 척수운동신경원의 흥분성 변화

        이정우,김태열,이인학,이준희,Lee, Jeong-Woo,Kim, Tae-Youl,Lee, In-Hak,Lee, Joon-Hee 대한임상전기생리학회 2003 대한임상전기생리학회지 Vol.1 No.1

        The purpose of this study was to determine the effect of neuromuscular electrical stimulation(NMES) on the alteration of spinal motor neuron excitability. In this article, I would like to experiment on a standard capacity of clinical electrophysiology, a difference in applying methods and a clinical efficiency of NMES by Nerve conduction velocity. We used normal eight subjects without neuromuscular disease and all subjects participated 3 session, which at least 1 week between session. Participants classified according to each group in Antagonist, Agonist, Antagonist-Agonist by the NMES. The test was measured continuously pre test, post-test, post 20 minute test by EMG including H reflex, F wave, motor nerve conduction velocity(MNCV). The following results were obtained; 1. H-reflex latencies and H/M intervals were significantly increased in agonist and antagonist-agonist group(p<.01). 2. H-reflex amplitudes and H/M ratios were significantly decreased in agonist and antagonist-agonist group(p<.01). In agonist group, H-reflex amplitudes and H/M ratios were more significantly decreased than antagonist group. 3. F-wave latencies were significantly increased in agonist and antagonist-agonist group(p<.01). F/M intervals were significantly increased in antagonist-agonist group(p<.01). F wave conduction velocities were significantly increased in agonist and antagonist-agonist group(p<.01) but F/M ratios were not significant. 4. MNCV were significantly decreased in agonist(p<.01). These results lead us to the conclusion that agonist and Antagonist-agonist was significantly decreased excitability of spinal motor neuron. Conversely, Antagonist does not decreased. Therefore, A further direction of this study will be to provide more evidence that NMES have an effect on excitability of spinal motor neurons in UMN syndrome.

      • KCI등재

        정상 여성에게서 앞 정강근의 수축훈련방법에 따른 뇌파의 변화

        이정우,김문정,윤세원,Lee, Jeong-Woo,Kim, Moon-Jeong,Yoon, Se-Won 대한물리치료학회 2012 대한물리치료학회지 Vol.24 No.2

        Purpose: This study aims to examine the power changes in eletrocenphalogram (EEG) detected from the tibialis anterior muscle, during repetitive contraction exercise in normal female adults. Methods: The subjects of this study were 24 normal adult females, with no musculoskeletal or nervous system disorders. The 24 female subjects were divided into two groups: 12 subjects comprised a voluntary stimulation training group, and the other 12 subjects comprised an electrical stimulation training group. A total of thirty contractions were made repetitively by each woman, with maximal voluntary contraction exercise for six seconds, and a resting time of three seconds. During the experiment, their EEG was measured at eight positions. The eight positions were Fpz, Fz, Cz, CPz, C3, C4, P3, and P4, in accordance with the international 10~20 system. Results: The relative alpha power and beta power showed no statistically significant differences between the two groups. But the relative gamma power of the CPz, C3, C4, P3, and P4 areas showed statistically significant differences between the two groups (p<0.05). The relative theta power of the C4 area showed statistically significant differences between the two groups (p<0.05). Conclusion: Our findings show that tibialis anterior muscle contraction by electrical stimulation and by voluntary repeated contraction differentially affected brain activation. In particular, the CPz, C3, C4, P3 positions of relative gamma power showed brain activation in voluntary contraction. The C4 position of relative theta power showed different brain activation between the two groups.

      • 전기생리학적 기전에 근거한 망막 모델의 제안과 시공간적 응답의 분석

        이정우,채승표,조진호,김명남,Lee, Jeong-Woo,Chae, Seung-Pyo,Cho, Jin-Ho,Kim, Myoung-Nam 대한전자공학회 2002 電子工學會論文誌-SC (System and control) Vol.39 No.6

        본 논문에서는 망막의 전기생리학적 기전을 바탕으로 실제 망막과 유사한 기능 및 응답 특성을 갖는 망막 모델을 제안하였다. 시세포에서 양극세포까지는 기존에 연구된 여러 망막 모델들을 종합하여 모델링하였고, 3 NDP 기전을 이용하여 움직임 정보를 검출한다고 알려져 있는 아마크린세포와 양극세포 터미널에 관한 새로운 모델을 제안하였다. 이 모델의 평가를 위하여, 공간상의 동적 자극과 정지 자극에 대한 응답 특성을 비교 분석을 하였을 뿐만 아니라 자극의 움직임 속도에 따른 특성에 대한 분석도 수행하여 제안한 망막 모델을 검증하였다. 본 연구결과는 움직임 정보를 검출하기 위한 비전 시스템에 대한 인간 시각 시스템의 적용 및 생체에 이식할 수 있는 인공 망막의 개발을 위한 기초 연구에 이용될 수 있을 것이다. Based on electrophysiological retina mechanism, a retina model is proposed, which has similar response characteristics compared with the real primate retina. Photoreceptors, horizontal cells, and bipolar cells are modeled based on the previously studied retina models. And amacrine cells known to have relation to movements detection, and bipolar cell terminals are newly modeled using 3 NDP mechanism. The proposed model verified by analyzing the spatial response characteristics to stationary and moving stimuli, and characteristics for different speeds. Through this retina model, human vision system could be applied to computer vision systems for movement detection, and it could be the basic research for the implantable artificial retina.

      • KCI등재

        유두상 혈관내막 증식증의 임상적 보고

        이정우,정호윤,이석종,김귀락,최강영,양정덕,조병채,Lee, Jeong-Woo,Chung, Ho-Yun,Lee, Seok-Jong,Kim, Gui-Rak,Choi, Kang-Young,Yang, Jung-Dug,Cho, Byung-Chae 대한성형외과학회 2010 Archives of Plastic Surgery Vol.37 No.3

        Purpose: Intravascular papillary endothelial hyperplasia (IPEH), also known as Masson's pseudoangiosarcoma, is a rare disease which is now considered as a reactive process of the endothelium rather than a benign neoplasm. It can occur in any blood vessels in the body but more common in the head and neck region as a solitary, often tender, bluish or reddish nodule. IPEH is characterized by the development of endothelial-lined papillary projections in a vascular lumen, usually associated with thrombotic material, the endothelial cells in the papillary structures showing only slight atypia and occasional mitotic Figures, the absence of tissue necrosis. Methods: 8 patients with IPEH were enrolled in the study from 2002 to 2007. All 8 lesions were surgically excised for histopathologic diagnosis. Results: 4 patients were female. The duration of the lesions ranged from 3 months to 15 years. The tumors were first noted between the ages of 20 and 72 years. 4 patients had lesions on the head; 2 on the toe; 1 on the back; and 1 on the finger, respectively. All lesions were solitary, ranged in size from 2 mm to 27 mm. There were no recurrences. Conclusion: The clinical appearance of IPEH is not specific, presented as a primary neoplasm, and the diagnosis can be established by microscopic examination. Complete surgical excision is the best choice of therapy for patients with IPEH, and is both diagnostic and curative. Awareness of this lesion will prevent incorrect diagnosis and overly aggressive treatment.

      • KCI등재후보

        역방향 조사방식을 통한 동적쐐기의 품질관리

        이정우,홍세미,서태석,Lee Jeong Woo,Hong Semie,Suh Tae Suk 한국의학물리학회 2004 의학물리 Vol.15 No.3

        쐐기형태의 선량분포를 만드는 데 이용되는 선형가속기에 장착된 동적쐐기(EDW; Enhanced Dynamic Wedge)의 품질관리를 위한 간단한 방법을 고안하였다. 선량 프로파일의 품질관리를 위해서는 필름 선량측정 장비와 필름 스캐너, 고 에너지 선량 측정용 필름, 필름 농도계, 삼차원 치료 계획 장치가 사용되었다. 역방향 60$^{\circ}$ 동적쐐기를 각각 한 필름에 조사(이하 60$^{\circ}$REWP; 60$^{\circ}$ Reversed Wedge Pair)하고, 이를 통해 얻어진 선량 프로파일의 선량 대칭도를 정량적으로 분석하였으며, 동적쐐기 구동이 중간에 멈춘 경우 이를 보상하는 부분 보상조사(Partial treatment mode)도 비교하였다. 또한 측정 된 자료들을 구간선량표(Golden STT; Segmented Treatment Table) 로 구현한 삼차원 치료 계획 장치의 계산치와 비교하였다 60$^{\circ}$REWP의 실험을 통해 역방향 쐐기의 효과가 1% 이내에서 잘 상쇄되었음을 알 수 있었으며 이 자료를 기준으로 한 품질관리의 타당성을 확보할 수 있었다. 실효쐐기인자의 품질관리를 위해서는 쐐기 각도 $10^{\circ}$, 15$^{\circ}$, 20$^{\circ}$, 25$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$, 60$^{\circ}$에 대해 실측하였고, 구간선량표에서 보정인자를 유도하여 동적쐐기 조사 시 자동으로 생성되는 로그 파일을 참조하여 실효 쐐기인자 계산치를 얻어내어 비교하였다. 이 방법을 통해 별도의 측정 장비 없이 용이하게 쐐기인자의 이상 유무를 파악할 수 있었다. 기존의 복잡한 품질관리의 방법을 단순화하고 효율을 극대화시킴으로써 측정에서 분석까지 1시간 내에 동적 쐐기의 품질관리를 수행할 수 있었다. 동적쐐기는 금속쐐기와 달리 선량률과 Y축 콜리메이터의 움직임에 따라 부정확도의 잠재가능성을 갖고 있으므로 수시 품질관리가 필수적인데 본 연구방법을 이용하면 단순하면서도 효율을 극대화할 수 있어 동적쐐기를 이용한 방사선치료의 안전도를 높일 수 있었다. A simplistic quality assurance (QA) method was designed for a Linac built-in enhanced dynamic wedge (EDW), which can be utilized to make wedged beam distributions. For the purpose of implementing the EDW symmetry QA, a film dosimetry system, low speedy dosimetry film, film densitometer and 3D RTP system were used, and the films irradiated by means of a 60$^{\circ}$ Reversed wedge pair (REWP) method. The profiles were then analyzed in terms of their symmetries, including partial treatment, which is the case of stopping it abruptly during EDW irradiation, and the measured and calculated values compared using the Cad Plan Golden Segmented Treatment Table (Golden STT). The result of this experiment was in good agreement, within 1 %, of the 'reversed wedge pair counterbalance effect'. For the QA of the effective wedge factor (EWF), the authors measured EWFs in relation to the 10$^{\circ}$, 15$^{\circ}$, 20$^{\circ}$, 25$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$ and 60$^{\circ}$ EDW, which were compared with the calculated values using the correction factor derived from the Golden STT and the log files produced automatically during the process of EDW irradiation. By means of this method it was capable of check up the safety of effective wedge factor without any other dosimetry system. The EDW QA was able to be completed within 1 hour from irradiation to analysis as a consequence of the simplified QA procedure, with maximized effectiveness. Unlike the metal wedge system, the EDW system was heavily dependent on the dose rates and jaw movements; therefore, its features could potentially cause inaccuracy. The frequent simplistic QA for the EDW is essential, and could secure against the flaw of dynamic treatment that uses the EDW.

      • KCI등재
      • KCI등재

        과다 유두(Supernumerary Nipple) 2례

        이정우,양정덕,이정훈,최강영,김귀락,정호윤,조병채,Lee, Jeong-Woo,Yang, Jung-Dug,Lee, Jung-Hun,Choi, Kang-Young,Kim, Gui-Rak,Chung, Ho-Yun,Cho, Byung-Chae 대한성형외과학회 2010 Archives of Plastic Surgery Vol.37 No.5

        Purpose: Supernumerary nipple or polythelia is one of the developmental anomalies occurring at the embryonic stage and this anomaly usually arises from the milk line. While this atypical feature is determined during early developmental stage, it may not come out obviously or become troublesome until puberty or lactation. Moreover, sometimes it is confused with a pigmented nevus. Methods: Case 1, a 18-year-old woman with intramammary supernumerary breast consisted of another nipple with middle sized areola on the right lower breast was admitted for a $2.8{\times}3.1\;cm$-sized mass on the right breast which was starting appeared 1 year earlier. The preliminary cytological examination of the material obtained by needle aspiration biopsy from the mass was revealed by fibroadenoma with no malignant change. The patient had the surgical excision of the mass and accessory breast. Case 2, a 16 year-old woman admitted for intra-areolar polythelia of the left breast, even she doesn't have any family history of polythelia. Since she wanted surgical correction of her atypical nipple for aesthetic and psychological reasons, we reconstructed the areola using transposition flaps in an S-plasty design. Results: Case 1, the excised supernumerary nipple showed following histological features. In the superficial layer, an acanthotic and hyperpigmented epithelium with elongated rete ridges was found. In the dermis, there were follicles with hairs surrounded by hypertrophic sebaceous glands. In the deepest portion, abundant secretory glomerules and excretory ducts of apocrine gland type were observed. Case 2, follow-up visits 3 months after the procedure showed a satisfactory result with good shape and projection of the nipple. Conclusion: We report two cases of aberrant mammary tissue who underwent surgical correction, including complete breast (with nipple, areola, and glandular tissue) and intra-areolar polythelia according to the Kajava's classification, and the results were satisfactory.

      • KCI등재

        공학교육 인증을 위한 메카트로닉스 전공 교육과정의 개발

        이정우,정연두,심병민,채경덕,한세범,황영택,Lee Jeong-Woo,Jeong Yeon-Doo,Sim Byoung-Min,Chae Kyung-Duck,Han Seh-Beom,Hwang Yeong-Taik 한국공학교육학회 2005 공학교육연구 Vol.8 No.2

        이 논문은 한국공학교육인증원의 공학교육인증 요구조건을 만족시키기 위한 삼척대학교 메카트로닉스 공학전공 교육과정의 연구에 관하여 기술하였다. 국내대학과 외국대학의 메카트로닉스 공학전공의 교육과정을 수집하고 분석하였다. 이 분석결과를 이용하고, 기계공학, 전기공학, 제어공학 그리고 컴퓨터공학의 유기적인 결합을 고려한 교육과정을 제시하였다. 더불어 삼척대학교의 지정학적인 조건과 한국공학교육인증원의 인증요구조건을 반영하였다. 그 결과 학생들에게 분석적인 능력과 실무적인 자질을 개발할 수 있도록 하는 다학제간 교육과정을 개발하였다. This paper describes the development of curriculum for the division of Mechatronics in Samcheok University to meet the requirement of Accreditation Board for Engineering Education of Korea(ABEEK). The curriculum of the department of mechatronics in South Korea and overseas university is analysed and then the curriculum is developed considering the synergistic combination of mechanical engineering, electronic engineering, control engineering and computer engineering. And then the geopolitical condition of university is reflected in the curriculum. ABEEK requirements for major of engineering are also reflected. As a result, interdisciplinary curriculum that provides analytic capability and pragmatic qualification to students is developed.

      • KCI등재

        고무댐에 적용하기 위한 유리섬유보강 복합재료 클랩핑 플레이트의 내구 특성

        이정우,박찬기,김종옥,이승기,김필식,Lee, Jeong-Woo,Park, Chan-Gi,Kim, Jong-Ok,Lee, Seung-Kee,Kim, Pil-Sik 한국농공학회 2011 한국농공학회논문집 Vol.53 No.5

        Steel clapping plate is used to connecting rubber body in rubber dam. However, once the steel clapping plate corrodes, it may cause faults, such as the same problems experienced by typical reinforcing steel. This study evaluated the applicability of glass fiber reinforced polymer composite(GFRP) clapping plate as a substitute for steel clapping plate. Absorption and load test were conducted to evaluate the decrease in durability of GFRP clapping plate exposed to deterioration environments. In the durability test results, the absorption rate of GFRP clapping plate was appeared as 0.6~1.0% in 50 day of immersion time. Also, the fracture load decreased with accelerated degradation environment exposure. Moreover, the absorption rate in GFRP clapping plate increased as degradation progressed, reducing the fracture load.

      • KCI등재

        세기변조방사선치료 선량분포 확인을 위한 2차원적 이온전리함 배열의 특성분석

        이정우,홍세미,김연래,최경식,정진범,이두현,서태석,Lee, Jeong-Woo,Hong, Se-Mie,Kim, Yon-Lae,Choi, Kyoung-Sik,Jung, Jin-Beom,Lee, Doo-Hyun,Suh, Tae-Suk 한국의학물리학회 2006 의학물리 Vol.17 No.3

        본 연구의 목적은 2차원적 이온전리함 배열의 특성을 분석하고 세기변조방사선치료 선량분포 확인의 유용성을 평가하기 위함이다. 본 실험에 사용된 2차원적 이온전리함 배열(MatriXX, Scanditronix-Wellhofer, IBA, Germany)은 $24{\times}24cm^2$ 범위에 1,024개의 평판형 전리함(용적: $0.08cm^3$, 직경: 4.5 mm, 높이: 5 mm, 배열간격: 7.62 mm)이 일정한 간격으로 배열되어있다. MatriXX의 특성분석을 위해 선량 직선성, 선량률 의존도, 출력 계수, 단기 선릉재현성을 분석하였으며, 선량분포 확인의 신뢰도를 평가하기 위해 Varian사의 동적쐐기와 세기변조 방사선치료의 선량분포를 분석하였다. 선량 직선성의 범위는 $1{\sim}800$cGy이었으며, 1% 미만의 오차율을 보였다. 선량률 의존성(범위 $100{\sim}600MU/min$)은 300 Mu/min을 기준으로 했을 때 모든 선량률 범위에서 0.4% 미만의 선량변화를 보였다. 또한, 물팬톰에서 0.1 cc 지두형 전리함으로 측정한 출력계수와 폴리스틸렌 팬톰에서 MatriXX로 측정한 출력계수를 비교하였다. 이 실험의 결과, $3{\times}3{\sim}24{\times}24cm^2$ 범위에서 0.5% 미만의 일치를 나타내었다. 단기 출력재현성 확인을 위하여 15분 간격으로 6회 측정한 결과, 0.5% 내의 차이를 보였다. 동적쐐기와 세기변조 방사선 조사면의 일치성 실험에서도 치료계획장치의 계산값과 필름측정값이 비교적 잘 일치함을 알 수 있었다. 본 연구를 통해 MatriXX의 물리적인 특성을 분석하였으며 세기변조방사선치료의 품질관리를 위한 유용성을 확인하였다. A commercial ion chamber matrix was examined the characteristics and its performance for radiotherapy qualify assurance. The device was the I'mRT 2D-MatriXX (Scanditronix-Wellhofer, Schwarzenbruck, Germany). The 2D-MatriXX device consists of a 1020 vented ion chamber array, arranged in $24{\times}24cm^2$ matrix. Each ion chamber has a volume of $0.08cm^3$, spacing of 0.762 cm and minimum sampling time of 20 ms. For the investigation of the characteristics, dose linearity, output factor, short-term reproducibility and dose rate dependency were tested. In the testing of dose linearity. It has shown a good signal linearity within 1% in the range of $1{\sim}800$cGy. Dose rate dependency was found to be lower than 0.4% (Range: 100-600 Mu/min) relative to a dose rate of 300 Mu/min as a reference. Output factors matched very well within 0.5% compared with commissioned beam data using a ionization chamber (CC01, Scanditronix-Wellhofer, Schwarzenbruck, Germany) in the range of field sizes $3{\times}3{\sim}24{\times}24cm^2$. Short-term reproducibility (6 times with a interval of 15 minute) was also shown a good agreement within 0.5%, when the temperature and the pressure were corrected by each time of measurement. in addition, we compared enhanced dynamic wedge (EDW, Varian, Palo Alto, USA) profiles from calculated values in the radiation planning system with those from measurements of the MatriXX. Furthermore, anon-uniform IMRT dose fluence was tested. All the comparison studies have shown good agreements. In this study, the MatriXX was evaluated as a reliable dosimeter, and it could be used as a simplistic and convenient tool for radiotherapy qualify assurance.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼