http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
큰 하악 평면각을 가진 골격성 II급 성장기 환자의 마이크로스크루 지지형 트윈 블록 장치 치료
이원강 대한치과교정학회 2022 대한치과교정학회 임상저널 Vol.12 No.4
This case report describes an orthopedic and orthodontic treatment of a young female patient who had skeletal Class II malocclusion with mandibular deficiency and vertical growth tendency. Favorable anterior growth of the mandible was acquired by using Twin-block appliance. In application of the Twin-block, it was modified using microscrew to reduce the side effects, like lower incisor proclination and upper incisor reclination, which reduces the potential of achieving maximum skeletal effects. The aim of this case report is to present an idea when using the Twin-block appliance. By this method, the proclination of the lower incisors and the reclination of the maxillary anterior teeth could be prevented. Moreover, the vertical growth of the maxillary dentition could be inhibited by using intraoral elastics between the microscrews and buttons on the Twin-block. This idea may be useful in the treatment of the growing skeletal Class II patients with deficient mandible.
소방전원보존형 발전기(RFP)의 작동 방법에 관한 연구
이원강,최충석 한국화재소방학회 2012 한국화재소방학회논문지 Vol.26 No.3
The purpose of this study is to propose an effective operating method of a power generator used by the Emergency Power System in case of a simultaneous fire and of the limitations of the interlock system the power supply from the emergency power generator. On the Emergency Power System with Reserved Fire-fighting Power (RFP), in case of an overload, the collective control Emergency Power System signals the main circuit breaker to shut off the supply to the emergency load, leaving the supply to the firefighting load uninterrupted to the end. The sequential control Emergency Power System signals the firefighting power supply to shut off the fire stage of the emergency load and continues to monitor the power supply. If an overload happens again from increased firefighting load, the sequential control Emergency Power System sends a secondary signal to shut down the second stage of the emergency load. 본 논문에서는 소방전원 및 소방전원 부족시 용량 보완을 위한 인터록 시스템의 한계점 등을 분석하고 소방전원 보존형 발전기(RFP)의 작동방법 등을 제시하여 화재와 같은 상황에 효율적으로 대응할 수 있는 방법을 제시하는데 있다. 소방전원보존형 발전기에서 일괄제어방식은 발전기에 과부하가 걸리면 소방전원보존용 제어기에서 신호를 발신하여 소방부하는 남겨두고 비상부하용 주차단기를 일괄 차단하고, 발전기가 마지막까지 소방부하에 전원이 공급되도록 한 시스템이다. 순차제어방식은 과부하가 걸리면 소방전원보존용 제어기에서 1차 신호를 발신하여 설정된 비상부하의 1단계 부하를 차단한다. 그리고 지속적인 감시 상태에서 소방부하가 증가하여 발전기가 다시 과부하가 걸리면 제어기에서 2차 신호가 발신하여 비상부하의 2단계 부하를 차단하는 시스템이며 각각의 작동 상태를 표시하는 표시장치를 가진다.