RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • SCIESCOPUSKCI등재

        Characterization and Field Measurements of NB-PLC for LV Network

        Masood, Bilal,Ellahi, Manzoor,Khan, Waheed Aftab,Akram, Waqar,Usman, Muhamad,Gul, Muhammad Talha The Korean Institute of Electrical Engineers 2018 Journal of Electrical Engineering & Technology Vol.13 No.1

        This paper presents a procedure for field measurements which provides a generalized Narrowband Power Line Communications (NB-PLC) channel model for low voltage (LV) access network in order to deploy advanced metering infrastructure (AMI) within Lahore, Pakistan. The measurements of allocated sites were performed in the residential (urban and rural), industrial and commercial electricity consumers for the NB-PLC channel modeling of overhead transmission lines (TLs). On the basis of extensive field measurement results, the average attenuation profile and transfer functions are presented. The results obtained from field measurements are validated by comparing them with a proposed Simulink model. A close agreement in the measured and simulated transfer function (TF) results is observed. The proposed Simulink model is an effort to model the NB-PLC channels in an effective way, especially in South Asian countries.

      • KCI등재

        Characterization and Field Measurements of NB-PLC for LV Network

        Bilal Masood,Manzoor Ellahi,Waheed Aftab Khan,Waqar Akram,Muhamad Usman,Muhammad Talha Gul 대한전기학회 2018 Journal of Electrical Engineering & Technology Vol.13 No.1

        This paper presents a procedure for field measurements which provides a generalized Narrowband Power Line Communications (NB-PLC) channel model for low voltage (LV) access network in order to deploy advanced metering infrastructure (AMI) within Lahore, Pakistan. The measurements of allocated sites were performed in the residential (urban and rural), industrial and commercial electricity consumers for the NB-PLC channel modeling of overhead transmission lines (TLs). On the basis of extensive field measurement results, the average attenuation profile and transfer functions are presented. The results obtained from field measurements are validated by comparing them with a proposed Simulink model. A close agreement in the measured and simulated transfer function (TF) results is observed. The proposed Simulink model is an effort to model the NB-PLC channels in an effective way, especially in South Asian countries.

      • KCI등재

        Effect of electrochemical reduction on the structural and electrical properties of anodic TiO2 nanotubes

        Muhammad Asim Rasheed,Kamran Ahmad,Nilem Khaliq,Yaqoob Khan,Muhammad Aftab Rafiq,Abdul Waheed,Attaullah Shah,Arshad Mahmood,Ghafar Ali 한국물리학회 2018 Current Applied Physics Vol.18 No.3

        The effect of electrochemical reduction on the structural and electrical properties of amorphous as well as annealed TiO2 nanotubes (TNTs) is investigated under ambient conditions. TNTs were prepared by anodizing titanium sheet in ethylene glycol electrolyte containing NH4F and de-ionized water at 40 V for 6 h. Electrochemical reduction is carried out in 1 M aqueous KOH solution for ~15 s at 3 V. TNTs are characterized by SEM, XRD, XPS and impedance spectrometer. XRD results confirm an increase in dspacing for (101) and (200) planes, after electrochemical reduction. XPS data reveal that electrochemical reduction produced prominent shifts of ~0.7e1.0 eV in the binding energies of TNTs. Interestingly, these shifts recover completely (in case of amorphous TNTs) and partially (in case of anatase TNTs) within ~7 days after reduction process due to oxygen uptake. Partial recovery in the binding energies of anatase TNTs is due to the fact that the oxygen vacancies are thermodynamically more stable as compared to amorphous TNTs. Similarly, the electrochemical reduction process decreases the impedance values of TNTs by more than three orders of magnitudes (from MU to kU). The impedance values also recover to the similar values before reduction in a span of ~7days.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼