RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • SCOPUSSCIEKCI등재

        Assessment and Comparison of Three Dimensional Exoscopes for Near-Infrared Fluorescence-Guided Surgery Using Second-Window Indocyanine-Green

        Cho, Steve S.,Teng, Clare W.,Ravin, Emma De,Singh, Yash B.,Lee, John Y.K. The Korean Neurosurgical Society 2022 Journal of Korean neurosurgical society Vol.65 No.4

        Objective : Compared to microscopes, exoscopes have advantages in field-depth, ergonomics, and educational value. Exoscopes are especially well-poised for adaptation into fluorescence-guided surgery (FGS) due to their excitation source, light path, and image processing capabilities. We evaluated the feasibility of near-infrared FGS using a 3-dimensional (3D), 4 K exoscope with near-infrared fluorescence imaging capability. We then compared it to the most sensitive, commercially-available near-infrared exoscope system (3D and 960 p). In-vitro and intraoperative comparisons were performed. Methods : Serial dilutions of indocyanine-green (1-2000 ㎍/mL) were imaged with the 3D, 4 K Olympus Orbeye (system 1) and the 3D, 960 p VisionSense Iridium (system 2). Near-infrared sensitivity was calculated using signal-to-background ratios (SBRs). In addition, three patients with brain tumors were administered indocyanine-green and imaged with system 1, with two also imaged with system 2 for comparison. Results : Systems 1 and 2 detected near-infrared fluorescence from indocyanine green concentrations of >250 ㎍/L and >31.3 ㎍/L, respectively. Intraoperatively, system 1 visualized strong near-infrared fluorescence from two, strongly gadolinium-enhancing meningiomas (SBR=2.4, 1.7). The high-resolution, bright images were sufficient for the surgeon to appreciate the underlying anatomy in the near-infrared mode. However, system 1 was not able to visualize fluorescence from a weakly-enhancing intraparenchymal metastasis. In contrast, system 2 successfully visualized both the meningioma and the metastasis but lacked high resolution stereopsis. Conclusion : Three-dimensional exoscope systems provide an alternative visualization platform for both standard microsurgery and near-infrared fluorescent guided surgery. However, when tumor fluorescence is weak (i.e., low fluorophore uptake, deep tumors), highly sensitive near-infrared visualization systems may be required.

      • Targeted Repair of CYBB in X-CGD iPSCs Requires Retention of Intronic Sequences for Expression and Functional Correction

        Sweeney, Colin L.,Zou, Jizhong,Choi, Uimook,Merling, Randall K.,Liu, Alexander,Bodansky, Aaron,Burkett, Sandra,Kim, Jung-Woong,De Ravin, Suk See,Malech, Harry L. Elsevier 2017 Molecular therapy Vol.25 No.2

        <P>X-linked chronic granulomatous disease (X-CGD) is an immune deficiency resulting from defective production of microbicidal reactive oxygen species (ROS) by phagocytes. Causative mutations occur throughout the CYBB gene, resulting in absent or defective gp91(phox) protein expression. To correct CYBB exon 5 mutations while retaining normal gene regulation, we utilized TALEN or Cas9 for exon 5 replacement in induced pluripotent stem cells (iPSCs) from patients, which restored gp91phox expression and ROS production in iPSC derived granulocytes. Alternate approaches for correcting the majority of X-CGD mutations were assessed, involving TALEN- or Cas9-mediated insertion of CYBB minigenes at exon 1 or 2 of the CYBB locus. Targeted insertion of an exon 1-13 minigene into CYBB exon 1 resulted in no detectable gp91phox expression or ROS activity in iPSC-derived granulocytes. In contrast, targeted insertion of an exon 2-13 minigene into exon 2 restored both gp91phox and ROS activity. This demonstrates the efficacy of two correction strategies: seamless repair of specific CYBB mutations by exon replacement or targeted insertion of an exon 2-13 minigene to CYBB exon 2 while retaining exon/intron 1. Furthermore, it highlights a key issue for targeted insertion strategies for expression from an endogenous promoter: retention of intronic elements can be necessary for expression.</P>

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼