http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Testicular Feminixation Syndrome의 1예
송용덕(YD Song),최호용(HY Choi),남상익(SI Nam),장윤석(YS Chang) 대한산부인과학회 1967 Obstetrics & Gynecology Science Vol.10 No.8
A case of Testicular Feminization Syndrome, who is an essentially normal-appearing woman, and have undescended testes instead of ovaries, is presented.
면역학적 및 생물학적 반응을 이용한 임신요중 HCG의 역가 측정에 대하여
송용덕(YD Song),장윤석(YS Chang),나건영(KY Na) 대한산부인과학회 1971 Obstetrics & Gynecology Science Vol.14 No.6
면역학적 및 생물학적 반응을 이용한 임신요중 HCG의 역가 측정을 통하여 신속한 HCG역가산정에도 사용할 수 있다. The usefulness of guantitative immunologic test for human chorionic gonadotropin in the urine was studied. A compartaive study of titration between the slide immunologic and biologic test was given and the results were as follows; 1. 127 cases of normal pregnancy, 10 cases of non-pregnancy, 1 case of destructive mole, 4 cases of hydatidiform Mole, 3 cases of chorio-carcinoma, totaling 145 cases were studied. 2. Both tests were negative in non-preg, women. 3. The peak level of H.C.G. excretion in urine in normal pregnancy takes place between 6 and 14 weeks (esp. 8-10wks) following the last menstrual period. There is then a gradual decrease during the second trimester, and slight increase during the third trimester. 4. The H.C.G. titers of immunologic preg test in urine is higher than of biologic test, but the patterns of both curves are not different. 5. Diagnostic accuracy was found to be 98.0% with slide test, and 77.0% with frog test, during 6-14 wks of gestation period, and the general diagnostic accuracy was 92.8% with slide test, 48.4% with frog test. 6. The H.C.G. titers were higher in the 4 cases of hydatidiform mole than the upper limit in the normal pregnancy. 7. The slide immunologic pregnancy test was found to be a rapid, accurate, but still expensive, and be able to evaluate the H.C.G. titers with this method.
이규하(KH Lee),송용덕(YD Song),이동경(TK Lee) 대한산부인과학회 1965 Obstetrics & Gynecology Science Vol.8 No.11
The antero-posterior diameters of the various pelvic planes in 63 Korean women were measured through the Hodge-Dippel method of X ray pelvimetry. The results obtained were as following. 1) The average length of anatomical true conjugate was 11.77 +/- 0.11 cm. 2) The average length of obstertrical true conjugate was 11.05 +/- 0.12 cm. 3) The average length of diagonal conjugate was 12.41 +/- 0.14 cm. 4) The average length of A-P diameter of the wide pelvic plane was 12.18 +/- 0.12 cm. 5) The average length of A-P diameter of the outlet was 11.65 +/- 0.14 cm. 6) The average length of external conjugate of the inlet was 17.81 +/- 0.13 cm.
Rh혈형부적합으로 인하여 고빌리루빈 혈치를 동반한 쌍태아 및 막상제대부착태반
이원기(WK Lee),송용덕(YD Song),김선원(SO Gim),박양실(YS Park) 대한산부인과학회 1967 Obstetrics & Gynecology Science Vol.10 No.7
A case of twin combined with hyperbilirubinenia due to Rh in compatibility, and velamentous insertion of cord are presented. The sex and the weight of these babies were as follows; 2.5kg (female), 2.9kg(male). These two babies were relatively well ellapsed without exchange transfusion during admission although the biliubin levels were high, and discharged uneventfully.
이규하(KH Lee),이동경(TK Lee),송용덕(YD Song) 대한산부인과학회 1965 Obstetrics & Gynecology Science Vol.8 No.12
Electrolyte determinations and crystallization tests were done in the amniotic fluid of 26 normal parturients. The following results were obtained: 1) Mean amniotic fluid sodium ion concentration was 137.5 +/- 10.75 mEq. perliter. 2) Mean potassium ion concentration was 5.17 +/- 0.84 mEq. per liter. 3) Arborization phenomena were observed in the dry smears of all cases.
정상산모및 제대혈청 중 Na, K 및 Cl 함량에 관하여
이규하(KH Lee),이동경(TK Lee),송용덕(YD Song) 대한산부인과학회 1965 Obstetrics & Gynecology Science Vol.8 No.11
1) Sodium, potassium and chloride ion concentrations were determined in 37 cases of maternal blood and cord blood of normal full-term paturients. 2) No significant difference of sodium ion concentration was noticed between the maternal blood (151.31 +/- 7.00 mEq./L.) and the cord blood(152.58 +/- 13.93 mEq./L.). Postassium ion concentration was lower in the maternal blood(4.74 mEq./L.) than in the cord blood (8.99 +/- 4.13 mEq./L.). No significant difference of chloride ion was noticed between the maternal (122.86 +/- 7.58 mEq./L.) and the cord blood(124.00 +/- 12.90 mEq./L.). 3) Sodium ion concentration of the amniotie fluid(137.52 +/- 10.74 mEq./L.) was the lowest than those of the maternal blood and the cord blood. Potassium ion concentration of amniotic fluid(5.17 +/- 0.84 mEq./L.) was higher than that of the maternal blood and lower than that of the cord blood.