As part of the recent low-energy policy, insulation standards for buildings are increasing every year. In addition, the conventional styrofoam heat insulation material has a problem in that the thickness of the heat insulation material to achieve the standard heat transmission rate is rapidly increased. Although the risk of spreading the structure vulnerable to fire due to insufficient spacing between buildings due to thickened insulation is increasing, the high cost of high efficiency insulation is difficult to solve. On the other hand, it is known that the method to be used as a formwork using insulation is excellent in cost reduction effect by reducing the amount of formwork used and simplifying the subsequent insulation work. The purpose of this study is to evaluate the strength characteristics of multi - layered insulation materials with appropriate strength by reducing the thickness of the insulation by appropriately combining high performance phenolic foam insulation and styrofoam insulation.
류화성 ( Ryu Hwa-sung ),신상헌 ( Shin Sang-heon ),송성용 ( Song Sung-yong ),김득모 ( Kim Deuck-mo ) 한국건축시공학회 2019 한국건축시공학회 학술발표대회 논문집 Vol.19 No.1
In modern times, due to the centralized urban structure, the interval between buildings is narrow and the increase of the heat island phenomenon due to the accumulation of the structure is becoming a social problem. In order to solve these problems, various materials for reducing the surface temperature of buildings are under study. Particularly, in the case of a wall part which is a part directly affected by the outside air of the building, it is a main structural part for determining the room temperature. The purpose of this study was to develop a material that can improve the thermal environment performance of the building by evaluating the temperature control performance of the exterior finishing material using the heat reflecting material as a method for controlling the temperature of the outer wall finishing material.
류화성 ( Ryu Hwa-sung ),신상헌 ( Shin Sang-heon ),송성용 ( Song Sung-yong ),김득모 ( Kim Deuck Mo ) 한국건축시공학회 2019 한국건축시공학회 학술발표대회 논문집 Vol.19 No.2
As part of recent low-energy policies, thermal insulation standards for buildings are being tightened every year. The importance of external insulation methods is increasing due to the strengthening of insulation standards. Among the main materials used in the external insulation method, dry bit material is a finishing material composed of an organic binder and aggregate. When the fire occurs, the ignition of the surface part causes a direct fire on the thermal insulation material at the rear side when heat energy is concentrated. Therefore, it is important that the finishing material in dry insulation using a dry bit has a low fire spreading property in case of a fire and does not have a sustained combustion. The purpose of this study was to evaluate the fire spreadability by changing the internal fillers while using alkoxide-based acrylic emulsions, hybrid acrylic emulsions, and general acrylic emulsions in order to suppress the fire spreading properties of exterior finish materials.
건축물 외단열재의 열전달평가를 통한 화재 억제 방안 연구
류화성 ( Ryu Hwa Sung ),신상헌 ( Shin Sang Hun ),송성용 ( Song Sung Young ),김득모 ( Kim Deuck Mo ) 한국건축시공학회 2018 한국건축시공학회 학술발표대회 논문집 Vol.18 No.1
Improvement of insulation performance of buildings is a major part. Adiabatic method The adiabatic method minimizes the heat loss of the building. External insulation uses insulation to prevent fire. Ambient air hazards are less prone to fire. When a fire occurs, a phenolic pattern is formed and bond strength with the wall increases. EPS insulation and phenol foam were used to compare external heat transfer and external heat transfer. The heat transfer properties of phenolic foam and styrofoam were evaluated as follows. In the mortar and styrofoam structure, the problem of styrofoam reaching the burning point occurred before the collapse of the mortar, and the phenol foam had a problem in that when the direct fire was continued on the phenol foam, , The characteristics of continuous infiltration appeared. In the case of mortar and phenol foam + styrofoam, the heat penetrated into the interior due to the shrinkage due to the shrinkage of the carbon screen on the phenol foam. However, when reinforced with glass mesh on the outer surface, And to reduce infiltration.
류화성 ( Ryu Hwa-sung ),박원준 ( Park Won-jun ) 한국건축시공학회 2021 한국건축시공학회지 Vol.21 No.3
본 연구에서는 Lab. 스케일 LIBS 장치를 제작하여 모르타르 내 염화물 분석에서의 LIBS 적용성과 재현성 검토를 수행하였다. 염화물 함량을 조절한 모르타르를 대상으로 기존의 분석방법(XRF, 전위차 적정법)과 LIBS 분석을 동시에 진행하였다. LIBS 분석 결과, 염소이온은 837.59nm 파장에서 검출되었고, 다양한 농도 구간에서의 정밀도를 향상시키기 위하여 전기장 강화를 통한 약 50배의 LIBS 신호증폭을 구현하였다. 수용액 기반의 재현성을 검증을 통하여 LIBS 신호 강도와 Cl농도 사이의 높은 상관관계를 확인할수 있었으며, 콘크리트 염해 내구성 진단에 LIBS적용 가능성을 확인하였다. LIBS has been attracting attention as an analytical method capable of real-time measurement without sample preparation. In this study, a Lab. scale LIBS device was fabricated to examine the applicability and reproducibility of LIBS in the analysis of chloride contents in mortar. The existing analysis method and LIBS analysis were performed simultaneously on the mortar test specimen with the chloride content adjusted. Compared to the chloride content condition of the mortar, the XRF and Potentiometric Titration results also showed a similar trend. As a result of LIBS analysis, chlorine ions were detected at a wavelength of 837.59 nm according to the chloride content condition. In order to improve the precision in various concentration ranges, the LIBS signal amplification of about 50 times through the electric field enhancement was implemented. Through the verification of the aqueous solution-based reproducibility, a high correlation between the LIBS signal strength and the Cl concentration was confirmed, and the possibility of applying LIBS to the durability diagnosis of concrete damage by chloride was confirmed.