http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Factors Influencing Bond Properties in Concrete Encased Steel Columns at High Temperatures
Yuzhuo Wang,Ziqing Liu,Guoqiang Li,Jian Jiang,Ying Gao,Chuanguo Fu 한국강구조학회 2020 International Journal of Steel Structures Vol.20 No.3
This paper presents experimental results on factors governing the bond strength between steel and concrete in concrete encased steel (CES) columns at high temperatures. Push-out tests were conducted on 22 CES specimens to investigate the bond strength between concrete and steel under the temperature of 250 °C, while one specimen was tested at room temperatures for comparison. Data obtained from these tests revealed that the bond properties of CES structures between steel and concrete is infl uenced by a number of factors, including concrete strength, concrete cover thickness, stirrup reinforcement ratio, steel ratio and anchorage length of steel at high temperatures. The formulas for predicting the ultimate bond strength and slip between steel and concrete of CES structures are proposed based on the experimental investigations.
Experimental and numerical study on tensile capacity of composite cable-girder anchorage joint
Xuefei Shi,Yuzhuo Zhong,Haiying Ma,Ke Hu,Zhiquan Liu,Cheng Zeng 국제구조공학회 2023 Steel and Composite Structures, An International J Vol.49 No.2
Cable-girder anchorage joint is the critical part of cable-supported bridges. Tensile-plate anchorage (TPA) is one of the most commonly used types of cable-girder anchorage joints in steel girder cable-supported bridges. In recent years, it has been proposed by bridge designers to apply TPA to concrete girder cable-supported bridges to form composite cable-girder anchorage joint (CCGAJ). In this paper, the mechanical performance of CCGAJ under tensile force is studied through experimental and numerical analyses. Firstly, the effects of the external prestressing (EP) and the bearing plate (BP) on the mechanical performance of CCGAJ were investigated through three tests. Then, finite element model was established for parametrical study, and was verified by the experimental results. Then, the effects of shear connector forms, EP, BP, vertical rebar rate, and perforated rebar rate on the tensile capacity of CCGAJ were investigated through numerical analyses. The results show that the tensile capacity of CCGAJ depends on the first row of PR. The failure mode of CCGAJ using headed stud connectors is to form a shear failure surface at the end of the studs while the failure mode using PBLs is similar to the bending of a deep girder. Finally, based on the strut-and-tie model (STM), a calculation method for CCGAJ tensile capacity was proposed, which has a high accuracy and can be used to calculate the tensile capacity of CCGAJ.
Dongmin Zhao,Qing Tao Liu,Xinmei Huang,Huili Wang,Kaikai Han,,Jing Yang,Keran Bi,Yuzhuo Liu,Lijiao Zhang,Yin Li 대한수의학회 2018 Journal of Veterinary Science Vol.19 No.4
Heat shock protein A9 (HSPA9), a member of the heat shock protein family, is a putative receptor for Tembusu virus (TMUV). By using Western blot and co-immunoprecipitation assays, E protein domains I and II were identified as the functional domains that facilitate HSPA9 binding. Twenty-five overlapping peptides covering domain I and domain II sequences were synthesized and analyzed by using an HSPA9 binding assay. Two peptides showed the capability of binding to HSPA9. Dot blot assay of truncated peptides indicated that amino acid residues 19 to 22 and 245 to 252 of E protein constitute the minimal motifs required for TMUV binding to HSPA9. Importantly, peptides harboring those two minimal motifs could effectively inhibit TMUV infection. Our results provide insight into TMUV–receptor interaction, thereby creating opportunities for elucidating the mechanism of TMUV entry.