김영수,Kim, Yung-Soo 대한치과보철학회 1978 대한치과보철학회지 Vol.16 No.1
The author conducted an experiment of recording side shift of the lateral mandibular movement and analyzing the timing of the side shift on the twenty-two non-functioning side condyles. As a result, clinically useful informations were obtained. The findings were as follows: 1. On all the non-functioning side condyle path, during the first four millimeters of forward movement, the change in the rate of the mandibular side shift was observed. 2. Band E types of the mandibular side shift ,which have shown a distinct rate of immediate side shift were fifteen condyles, and C type of the mandibular side shift which has shown the greatest rate of the side shift occurs early in the first four millimeters of forward movement was seven condyles. 3. A and D types which have shown generally progressive and distributed nature were not observed.
LOADED IMPLANT와 UNLOADED IMPLANT의 조직학적 비교 연구
김영수,고재승,황성명,Kim, Yung-Soo,Ko, Jea-Seung,Hwang, Sung-Myung 대한치과보철학회 1991 대한치과보철학회지 Vol.29 No.2
In order to see the possible effect of the functional load-bearing after osseointegration of the titanium root form implant in dog a histologic study was conducted. One side of lower jaw was surgically prepared edentulousness and titanium implants were inserted. Some implants were functionally loaded through fixed detachable prosthesis and some are isolated and unloaded. The dog was sacrificed four months later and bone sections with implants were processed for histologic evaluation and the results were as follows ; (1) The bone to implant interface after four months of load bearing presented no mobility and no marginal bone loss radiographically and histologically. (2) The interface zone between compact bone and implant revealed a direct bone to implant contact and in some areas marrow tissue contacts were examined at the light microscopic level. (3) At the ultrastructural level the interface of surrounding compact bone matrix and implant, three types of superficial layers were found ; one with moderate electron dense amorphous granular substance layer, other with high electron dense fine granular substance layer, and another type of amorphous granular substance covered with high electron dense line of minute granules. (4) The osteoblasts in the marrow tissue neighboring implants and osteocytes in compact bone showed typical normal characteristics and in the marrow tissues some of lymphocytes and mast cells were observed. (5) The abscence of abnormal tissue reactions at a cellular level indicates a high degree of biocompatibility for the experimental titanium implant and basically no difference was found between functionally loaded and unloaded implants.
김영수,Kim, Yung-Soo 대한치과보철학회 1979 대한치과보철학회지 Vol.17 No.1
This investigation was to analyse normal protrusive and lateral condylar pantographic records written on the sagittal plane and to study components of Fisher's angle and their interrelations. The purpose of this study was limited to (1) discussing the significance of sagittal pantographic record in diagnosis of occlusal disease and(2) basing for reasoning validity of measuring Fisher's angle which has been reported so far. As a result followings were concluded. 1. In each protrusive and lateral condylar movement path, five complicate factors such as initial straightness, distributed simple sigmoid type, simple curvature, initial tiny protruding convexity and tiny repeated sigmoid patterns were noted. Generally each condylar movement path was composed of two to three of these factors. 2. The distribution of positional interrelations of protrusive and lateral condylar paths could be divided into five categories; (a) protrusive-upper, (b) completely coinciding, (c) partially initial coinciding, (d) partially inverted crossing, and (e) completely inverting. Among these, protrusive path-upper positioned condyles were prevailed (79.2%). 3. The distribution of interrelations of protrusive and lateral condylar paths could be devided into five categories according to their distances in the course of movement. Among these, opening (95.8%) and paralleling (66.7%) were prevailing. 4. The involved number of characteristic heterogenous patterns of five categories in protrusive and lateral condylar movement recording relations at one simultaneous recordings was limited to three. However, in case of homogeneous patterns were repeated, usually three to four were included. 5. The maximum distance between protrusive and lateral condylar paths was 1.45mm at the location of 4mm advanced position from centric relation point and 3.90mm at the location of protrusive movement terminal. 6. It seemed to be that ,pantographic records should be consulted other clinical symptoms in order to make certain occlusion diagnosis. 7. At the present moment of investigation, expressing Fisher's angle as a degree revealed a lack due to inherent complexity of protrusive and lateral condylar movement paths. 8. The typical pattern of protrusive and lateral condylar paths written on a pantographic sagittal plate might be described as follows; (a) protrusive condylar path should be positioned upwardly, (b) both mainly be simple curvature, (c) interrelations mainly be opening or paralleling. 9. The mean amounts of separation between protrusive and lateral condylar movement path were $0.75{\pm}0.46$ at 4mm advanced location from centric relation and $1.74{\pm}0.64mm$ at the location of protrusive path terminal.