http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Strong fuzzy hyperK-subalgebra
Y.H. KIM(김영희),K.A. OH(오경아),T.E. JEONG(정태은) 한국지능시스템학회 2003 한국지능시스템학회논문지 Vol.13 No.3
In this paper, we define a strong fuzzy hyperK-subalgebra and investigate between a strong fuzzy hyperK-subalgebra and a fuzzy hyperK-subalgebra. And then we give some properties of a weak homomorphism and a strong fuzzy hyperK-subalgebra.
Weak positive implicative hyperBCK-ideal
Y.H.Kim(김영희),Y.M.Namkoong(남궁윤미),T.E.Jeong(정태은) 한국지능시스템학회 2003 한국지능시스템학회논문지 Vol.13 No.2
In this paper we define a weak positive implicative hyperBCK-ideal of hyperBCK-algebra. Also we investigate that every positive implicative hyperBCK-algebra is a positive implicative hyperK-algebra and then we prove that every positive implicative hyperK-algebra is a weak positive implicative hyperK-algebra.
권계철,정태은,임찬빈 충남대학교 의과대학 지역사회의학연구소 1998 충남의대잡지 Vol.25 No.1
The chemiluminescent immunoassay has been chosen as a method of special protein and hormone measurement because radioactive isotope was not to be used in this method and has a high performance of hormone and special protein assay. ACS :18O^TM (Ciba-Corning :Diagnostics Corp. USA) is an automatic chemiluminescent immunoassay analyzer using acridinium ester as a nonradioactive tag. The linearity, accuracy, precision and correlation study with a radioimmunoassay(RIA) method was performed to evaluate the usefulness of ACS:180^TM autoanalyzer concerning four items (CEA, LH, FSH and Prolactin). The results were as follows: 1. Within run coefficients of variation(CV) at 20 runs with control serum of CEA, Lll, FSH and Prolactin were 9.39%, 2.07%, 2.34% and 2.15% respectively. 2. Between run CV at 20 days with control serum of CEA, LH, FSH and Prolactin were 9. 64%, 3.07%, 3.73% and 6.84% respectively. 3. The percentage of variation in CEA, LH, FSH and Prolactin were 2.86%, 2.42%, 4.82%, 6.28% to evaluate accuracy with the control serum measured 20 times. 4. The linearity of CEA, LH, FSH and Prolactin were evaluated with the control serum diluted 100:0, 80:20, 60:40, 40:60, 0:100. The regression equation of those were Y=0.318X+2.93(R=0.979), Y=0.361X-0.190(R=0.995), Y=0.502X+4.001(R=0.998) and Y=0.264X+5.112(R=0.994). 5. The correlation of the CEA, LH and Prolactin with RIA were Y=0.789X+0.914(R=0.990), Y=0.877X+0.808(R=0.984), Y=0.867X-0.102(R=0.948). and hormones tests because of its high precision, good accuracy, linearity and high correlation with R1A.