http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Kajimoto, T.,Shigyo, N.,Sanami, T.,Iwamoto, Y.,Hagiwara, M.,Lee, H.S.,Soha, A.,Ramberg, E.,Coleman, R.,Jensen, D.,Leveling, A.,Mokhov, N.V.,Boehnlein, D.,Vaziri, K.,Sakamoto, Y.,Ishibashi, K.,Nakashim North-Holland Physics Pub 2014 Nuclear instruments & methods in physics research. Vol.337 No.-
The energy spectra of neutrons were measured by a time-of-flight method for 120GeV protons on thick graphite, aluminum, copper, and tungsten targets with an NE213 scintillator at the Fermilab Test Beam Facility. Neutron energy spectra were obtained between 25 and 3000MeV at emission angles of 30<SUP>o</SUP>, 45<SUP>o</SUP>, 120<SUP>o</SUP>, and 150<SUP>o</SUP>. The spectra were parameterized as neutron emissions from three moving sources and then compared with theoretical spectra calculated by PHITS and FLUKA codes. The yields of the theoretical spectra were substantially underestimated compared with the yields of measured spectra. The integrated neutron yields from 25 to 3000MeV calculated with PHITS code were 16-36% of the experimental yields and those calculated with FLUKA code were 26-57% of the experimental yields for all targets and emission angles.
Measurement of High Energy Neutron Induced Cross Sections for Chromium
S. Sekimoto,T. Utsunomiya,H. Yashima,H. Joto,S. Shibata,K. Ninomiya,D. Satoh,Y. Iwamoto,T. Omoto,R. Nakagaki,N. Takahashi,A. Shinohara,T. Shima,M. Hagiwara,H. Matsumura,K. Nishiizumi,Y. Matsushi,H. Ma 한국물리학회 2011 THE JOURNAL OF THE KOREAN PHYSICAL SOCIETY Vol.59 No.23
Reaction cross sections for Cr induced by neutrons at 287 MeV were measured by using ^7Li(p,n) reaction at N0 beam line in the Research Center for Nuclear Physics (RCNP), Osaka University. To estimate quasi-monoenergetic neutron-induced cross sections, the Cr sample was irradiated on the two angles of 0° and 30° for the axis of the primary proton beam. Proton-induced reaction cross sections for Cr at 300 MeV were also measured. The measured cross section data in the ^(nat)Cr(n,x) and ^(nat)Cr(p,x) reactions are compared with the literature values and the JENDL high-energy file. Furthermore, those in the ^(nat)Cr(n,x) reactions are also compared with those in the ^(nat)Cr(p,x) reaction.
T. Sanami,M. Hagiwara,H. Iwase,M. Takada,D. Satoh,Y. Iwamoto,S. Kunieda,H. Yashima,A. Tamii,M. Baba 한국물리학회 2011 THE JOURNAL OF THE KOREAN PHYSICAL SOCIETY Vol.59 No.23
The experimental program to measure double differential cross section (DDX) data for fragment production is launched to establish reaction models and parameters for proton induced reaction on light-medium nuclei for the energy range from threshold to a few hundred MeV. In this program, a Bragg Curve Counter (BCC) that is improved to cover entire energy range of fragment is employed as a detector. DDXs of lithium, beryllium, boron and carbon emission at 30, 60, 90, and 135 degree were measured for 40, 50, 70, and 80 MeV proton on carbon, nitrogen, oxygen and aluminium Theoretical calculation results using three different intra-nuclear cascade models were compared with experimental data. By choosing appropriate model, the calculation generally reproduces the DDXs except for fragments having relatively high energy and small emission angle, and fragments from two body reaction.
M. Hagiwara,T. Sanami,K. Masumoto,Y. Iwamoto,N. Matsuda,Y. Sakamoto,Y. Nakane,H. Nakashima,Y. Uwamino 한국물리학회 2011 THE JOURNAL OF THE KOREAN PHYSICAL SOCIETY Vol.59 No.23
Nuclear data on proton-induced neutron and γ-ray production in the energy range from 10 to 20 MeV is important to estimate the shield design and activation of low-energy cyclotron facilities for medical use such as production of radiopharmaceuticals in positron emission tomography (PET). We have measured double-differential thick target yields (TTYs) of neutrons and γ-rays from a ^(18)O-enriched water (H^(18)_2O) target induced by 18 MeV protons in order to estimate leakage radiations from a cyclotron and the neutron-induced activation in the production process of the ^(18)F-tagged fluorodeoxyglucose (FDG) which is a common radiopharmaceuticals for PET. Neutrons and γ-rays were measured with 5.08 cm diameter × 5.08 cm long NE213 scintillators for eight laboratory angles between 15- and 150-degrees. After applying a neutron-γ-ray event separation using the pulse-shape-discrimination (PSD) technique the neutron and γ-ray events were analyzed by a time-of-flight (TOF) technique and an unfolding technique, respectively. The measured TTYs were compared with TENDL-2009 data library and the physical model calculations with MCNPX and PHITS. The calculated TTYs roughly agree with the measured data.
Kim, J.H.,Hagiwara, T. North-Holland Pub. Co ; Elsevier Science Ltd 2017 Systems & control letters Vol.107 No.-
<P>This paper considers linear time-invariant (LTI) sampled-data systems and studies their generalized H-2 norms. They are defined as the induced norms from L-2 to L-infinity, in which two types of the L-infinity norm of the output are considered as the temporal supremum magnitude under the spatial infinity-norm and 2-norm. The input/output relation of sampled-data systems is first formulated under their lifting-based treatment. We then develop a method for computing the generalized H-2 norms with operator-theoretic gridding approximation. This method leads to readily computable upper bounds as well as lower bounds of the generalized H-2 norms, whose gaps tend to 0 at the rate of 1/root N with the gridding approximation parameter N. An approximately equivalent discretization method of the generalized plant is further provided as a fundamental step to addressing the controller synthesis problem of minimizing the generalized H2 norms of sampled-data systems. Finally, a numerical example is given to show the effectiveness of the computation method. (C) 2017 Elsevier B.V. All rights reserved.</P>
Camera-based measurement for close-distance relative vessel positioning
Mizuchil, Y.,Ogura, T.,Kim, Y. B.,Hagiwara, Y.,Choi, Y. 대한기계학회 2017 JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY Vol.31 No.4
<P>This paper presents a technique for quickly and accurately measuring the position and heading of a vessel for relative vessel positioning at close distances to a target. To this end, we propose a measurement system that consists of camera units and landmarks. This system calculates the position and heading based on the distance and angle between the camera units on the vessel's side and landmarks on the target's side. Cameras with a high frame rate, wide sensing range, and excellent angular resolution are employed as sensors for measuring the position and heading, rather than GPS, radar, or lasers. A pattern-matching method based on the intensity gradient is developed in order to provide the proposed system with a fast response time. Correction methods for the distance measured by the camera unit and installation errors are also proposed to improve the accuracy of the measurement. We evaluated the accuracy of the proposed system using several positional relations between the camera units and landmarks. We demonstrate that the proposed system can accurately measure the position and heading of a vessel, despite the vessel's roll and pitch motion as a result of waves.</P>