RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Cardiovascular Surgery Patients: Intensive Care Experiences and Associated Factors

        Ozlem Aslan,Betül Tosun 한국간호과학회 2015 Asian Nursing Research Vol.9 No.4

        Purpose: The purpose of this study was to determine the intensive care unit (ICU) experiences of cardiovascular surgery (CS) patients and to define the associations between their ICU experiences and related factors. Methods: The study used a descriptive design. In total, 106 CS patients were interviewed at least 24 hours after discharge from an ICU in an educational research hospital in Ankara, Turkey between January and July 2012. Data were collected using the Intensive Care Experience Scale (ICES), a sociodemographic and clinical characteristics data form and two open-ended questions inquiring about smells and light. Statistical analyses were conducted using SPSS 15.0. Results: The patients were moderately aware of their ICU environments, partly recalled their ICU experiences, highly recollected frightening experiences, and expressed good satisfaction with care. Age, education, marital status, and pain were associated with ICU experiences. Patients who sensed smell had higher scores of frightening experiences than those who did not. Patients who were annoyed with excessive light reported less satisfaction with care than those who were not. Conclusions: The results suggest that measuring the patients' characteristics and environmental factors may be beneficial for healthcare teams to improve the recovery of CS patients in the ICU.

      • KCI등재

        Turkish Version of Kolcaba's Immobilization Comfort Questionnaire: A Validity and Reliability Study

        Betül Tosun,Ozlem Aslan,Servet Tunay,Aygül Akyüz,Hüseyin Ozkan,Dogan Bek,Semra Açıksoz 한국간호과학회 2015 Asian Nursing Research Vol.9 No.4

        Purpose: The purpose of this study was to determine the validity and reliability of the Turkish version of the Immobilization Comfort Questionnaire (ICQ). Methods: The sample used in this methodological study consisted of 121 patients undergoing lower extremity arthroscopy in a training and research hospital. The validity study of the questionnaire assessed language validity, structural validity and criterion validity. Structural validity was evaluated via exploratory factor analysis. Criterion validity was evaluated by assessing the correlation between the visual analog scale (VAS) scores (i.e., the comfort and pain VAS scores) and the ICQ scores using Spearman's correlation test. The Kaiser-Meyer-Olkin coefficient and Bartlett's test of sphericity were used to determine the suitability of the data for factor analysis. Internal consistency was evaluated to determine reliability. The data were analyzed with SPSS version 15.00 for Windows. Descriptive statistics were presented as frequencies, percentages, means and standard deviations. A p value .05 was considered statistically significant. Results: A moderate positive correlation was found between the ICQ scores and the VAS comfort scores; a moderate negative correlation was found between the ICQ and the VAS pain measures in the criterion validity analysis. Cronbach a values of .75 and .82 were found for the first and second measurements, respectively. Conclusions: The findings of this study reveal that the ICQ is a valid and reliable tool for assessing the comfort of patients in Turkey who are immobilized because of lower extremity orthopedic problems.

      • KCI등재

        Four flap suspension technique for prevention of bottoming out after breast reduction

        Yuksel Kankaya,Melike Oruc,Nezih Sungur,Ozlem Colak Aslan,Koray Gursoy,Kadri Ozer,U?ur Kocer 대한외과학회 2015 Annals of Surgical Treatment and Research(ASRT) Vol.90 No.1

        Purpose: Bottoming-out deformity is accepted as the most important disadvantage of inferior pedicle breast reduction. For prevention of this deformity, different techniques are used in combination with inferior pedicle. In this study, we aimed to prevent bottoming-out deformity by producing an internal bra effect through combination of inferior pedicle technique with 2 superior and 2 inferior dermal flaps that were raised from each side of the pedicle. Methods: Thirteen patients whose medical records became available during the follow-up period at Ankara Training and Research Hospital from January 2010 to January 2015 were included in this study. We retrospectively obtained patient medical records including demographic characteristics and clinical data. Superior dermal flaps were planned on both sides of the pedicle 2 cm inferior to the lower border of areola and inferior dermal flaps were planned 6 cm inferior to the superior dermal flaps. The superior and inferior dermal flaps were secured to the periosteum of the 2nd and 4th ribs respectively with permanent sutures. Results: Preoperatively, the average distance between the inframammary fold and areola was 13.9 cm (range, 11–18 cm). The average amount of breast parenchymal resection was 745 g (range, 612–1,496 g). The average distance between the inframammary fold and the lower border of the areola was 7.9 cm (range, 7.5–9 cm) on the postoperative first-year measurements. Conclusion: In conclusion, according to our study, suspension technique to prevent bottoming-out deformity is associated with an easier technique without the need for alloplastic or allogenic materials. Since fixation is performed to the ribs instead of soft tissues like the pectoral fascia or muscle, we believe that this fixation is more long lasting and can be an effective alternative to other suspension techniques.

      • KCI등재

        A Tie-Over Dressing Using a Silicone Tube to Graft Deep Wounds

        Cem Inan Bektas,Yuksel Kankaya,Kadri Ozer,Ruser Baris,Ozlem Colak Aslan,Ugur Kocer 대한성형외과학회 2013 Archives of Plastic Surgery Vol.40 No.6

        Background The most common cause of skin graft failure is the collection of blood or serous fluid underneath the graft. In our study, we describe the use of silicone tube for tie-over dressing to secure the skin graft margins with the aim of decreasing loss of the skin graft, particularly in grafting of deep wounds. Methods Between March 2008 and July 2011, we used this technique in 17 patients with skin defects with depths ranging from 3.5 to 8 mm (mean, 5.5 mm). First, the skin graft was sutured with 3/0 silk suture material from its corners. Then, a silicone round drain tube was sutured with 3/0 absorbable polyglactin 910 over the margins of the graft. Finally, long silk threads were tied over the bolus dressing, and the tie-over dressing was completed in the usual fashion. Results The mean follow-up was 7 months (range, 2−10 months) in the outpatient clinic. Graft loss on the graft margins due to hematoma or seroma was not developed. The results of adhesion between the graft and wound bed peripherally was excellent. Conclusions In our study, we suggest that use of a silicone tube for additional pressure on the edges of skin grafts in case of reconstruction of deep skin defects.

      • SCOPUSKCI등재

        A Tie-Over Dressing Using a Silicone Tube to Graft Deep Wounds

        Bektas, Cem Inan,Kankaya, Yuksel,Ozer, Kadri,Baris, Ruser,Aslan, Ozlem Colak,Kocer, Ugur Korean Society of Plastic and Reconstructive Surge 2013 Archives of Plastic Surgery Vol.40 No.6

        Background The most common cause of skin graft failure is the collection of blood or serous fluid underneath the graft. In our study, we describe the use of silicone tube for tie-over dressing to secure the skin graft margins with the aim of decreasing loss of the skin graft, particularly in grafting of deep wounds. Methods Between March 2008 and July 2011, we used this technique in 17 patients with skin defects with depths ranging from 3.5 to 8 mm (mean, 5.5 mm). First, the skin graft was sutured with 3/0 silk suture material from its corners. Then, a silicone round drain tube was sutured with 3/0 absorbable polyglactin 910 over the margins of the graft. Finally, long silk threads were tied over the bolus dressing, and the tie-over dressing was completed in the usual fashion. Results The mean follow-up was 7 months (range, 2-10 months) in the outpatient clinic. Graft loss on the graft margins due to hematoma or seroma was not developed. The results of adhesion between the graft and wound bed peripherally was excellent. Conclusions In our study, we suggest that use of a silicone tube for additional pressure on the edges of skin grafts in case of reconstruction of deep skin defects.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼