http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Acute Myocardial Infarction in Patients With Single Coronary Artery: A Case Report
Nguyen Thi Huyen,Nguyen Ngoc Trang,Nguyen Khoi Viet,Le Thi Thuy Lien,Hoang Thi Van Hoa,Phung Bao Ngoc,Vu Dang Luu 아시아심장혈관영상의학회 2022 Cardiovascular Imaging Asia Vol.6 No.2
A single coronary artery (SCA) is a rare congenital anomaly. In most cases, it is an incidental finding on coronary angiography and has no clinical significance. However, it can cause angina, myocardial infarction, or even sudden death. Reports of SCA with acute myocardial infarction are very rare in the medical literature. This case study presents a patient with SCA from the right aortic sinus with severe stenosis in the proximal and distal part of the right coronary artery, which was detected using cardiac angiography and cardiac multidetector computed tomography (MDCT) with acute myocardial infarction.
Le Thi Thuy Lien,Nguyen Khoi Viet,Hoang Van Hoa,Phung Bao Ngoc,Nguyen Ngoc Trang,Vu Thi Kim Thoa,Nguyen Cong Tien,Phan Anh Phuong,Pham Minh Thong,Vu Dang Luu 아시아심장혈관영상의학회 2022 Cardiovascular Imaging Asia Vol.6 No.2
Objective: To compare left ventricular (LV) function, ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV), and regional wall motion analyzed in 256-slice dualsource coronary CT angiography (DSCT) with 2D transthoracic echocardiography (TTE). Materials and Methods: One hundred twelve patients suspected of coronary artery disease underwent DSCT and 2D-TTE within one week for LVEF, EDV, and ESV. The correlation between DSCT and 2D-TTE measurements was analyzed through linear regression and Bland- Altman analysis. Regional wall motion was visually scored with a 3-point scale (1, normal; 2, hypokinesia; 3, dysphagia, akinesia). Results: Average LVEF at 66.45%±1.27% (range 23%–85%) as determined on DSCT compared with 66.09%±1.01% (range 25%–84%) on 2D-TTE. LVEF exhibited a good correlation between DSCT and 2D-TTE (r=0.715; p<0.001). Good correlations between DSCT and 2D-TTE were demonstrated for LVEDV (r=0.732; p<0.001) and LVESV (r=0.841; p<0.001). Mean differences (±SD) of 1.78±24.10 mL (p<0.05) and 0.77±13.70 mL (p<0.05) were observed between DSCT and 2D-TTE for LVEDV and LVESV, respectively. LVEF was slightly overestimated with DSCT (0.52%±9.59%; p<0.05). Although the LVEF values calculated by DSCT and 2D-TTE were similar, EDV and ESV from DSCT were statistically higher than those from 2D-TTE (p<0.05). Agreement between DSCT and 2D-TTE in regional wall motion was 96.4%, κ=0.840. Conclusion: DSCT can provide comparable results to those using 2D-TTE for LV function (EF, EDV, and ESV) and regional wall motion assessment in a heterogeneous population.
Phung Bao Ngoc,Nguyen Khoi Viet,Hoang Van Hoa,Nguyen Ngoc Trang,Le Thi Thuy Lien,Pham Minh Thong,Vu Dang Luu 아시아심장혈관영상의학회 2022 Cardiovascular Imaging Asia Vol.6 No.2
Left pulmonary artery sling (LPAS) is a rare congenital anomaly in which the left pulmonary artery (LPA) originates from the posterior aspect of the right pulmonary artery and courses between the trachea and esophagus to reach the left lung. This anomaly causes distal tracheal and/or right main stem bronchus compression. Most LPAS cases are associated with early symptom onset, around 2 month-old, and have severe respiratory distress within the first year of life. There are two major types of LPAS based on the location of LPA and abnormal bronchial branching. The diagnosis can be made by using various imaging modalities. Herein, we present the imaging characteristics on multidetector computed tomography of 5 LPAS cases with respiratory distress (2 months to 12 months).
Minh-Huy Dinh Dang,Trang Thi Thu Nguyen,Bao Quang Gia Le,Linh Ho Thuy Nguyen,Ngoc Xuan Dat Mai,My Van Nguyen,Phuong Hoang Tran,Tan Le Hoang Doan 한국공업화학회 2022 Journal of Industrial and Engineering Chemistry Vol.111 No.-
Pd-incorporated Zr-based metal–organic framework containing sulfone groups, named Pd(II)BUT-11, wassuccessfully prepared by dispersing the sulfone-functionalized MOF in Pd(OAc)2 solution. X-ray diffraction,scanning electron microscopy, N2 isotherm sorption, X-ray photoelectron spectroscopy, and thermogravimetricanalysis were applied to determine the features of the Pd-incorporated MOF. In the catalyticstudies, Pd(II)@BUT-11 was shown to be an efficient heterogeneous catalyst for synthesizing various stilbenederivatives via the cross-coupling Heck reaction with DABCO-derived deep eutectic solvent (DES) asa green solvent. Notably, the catalyst and the solvent could be recovered and reused, with their activityand structure remaining stable throughout several trials. The method provides an alternative solution tothe conventional catalysts and solvents, resulting in a green and efficient stilbene synthesis process. Furthermore, the stilbenes were separated by extraction with ethyl acetate due to the low solubility ofDES with this solvent.