http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Rivas, Bernabé,L.,Maureira, Antonio,Geckeler, Kurt E. Wiley Subscription Services, Inc., A Wiley Company 2006 Journal of applied polymer science Vol.101 No.1
<P>Poly(4-acryloylmorpholine), poly(4-acryloylmorpholine-co-2-acrylamido-2-methyl-1-propane sulfonic acid), and poly(2-acrylamido-2-methyl-1-propane sulfonic acid) were synthesized by radical polymerization. The water-soluble polymers obtained, containing tertiary amino, amide, and sulfonic acid groups, were investigated, in view of their metal binding properties, as polychelatogens by using the liquid-phase polymer-based retention technique, under different experimental conditions. The metal ions investigated were Ag(I), Cu(II), Co(II), Ni(II), Cd(II), Pb(II), Zn(II), Cr(III), and Al(III). © 2006 Wiley Periodicals, Inc. J Appl Polym Sci 101: 180–185, 2006</P>
Influence of crack on the permeability of plastic concrete
Yongqiang He,Rayed Alyousef,Abdulaziz Alaskar,Hisham Alabduljabbar,Abdeliazim Mustafa Mohamed,Nelson Maureira-Carsalade,Angel Roco-Videla,Alibek Issakhov,Hamid Assilzadeh 국제구조공학회 2021 Smart Structures and Systems, An International Jou Vol.27 No.5
This study examined the relations between permeability of the concrete due to addition of new cracks. The different concrete types analyzed were standard concrete, reinforced steel fiber concrete, and reinforced concrete polypropylene fiber. In consideration of the improved polypropylene content of polypropylene fiber reinforced concrete, the crack diameter was decreased by 72-93% for up to 0.25% fiber and cracks were eliminated with 0.3% fiber inclusion. In terms of steel fiberreinforced concrete, the results showed that steel reinforcing macro fibers decrease the permeability of cracked concrete at wider crack widths. While the permeability of unreinforced concrete was the highest, 0.5% steel content resulted in lower permeability while a higher steel content concrete with 1% steel had the lowest permeability. Crack stitching phenomenon and the effect of multiple cracks may be attributed to the decrease in the permeability. With respect to normal concrete, the findings showed the crack opening displacement at the highest tension is less than 20 microns. At this loading stage, after unloading, around 80% of the displacement is restored and the residual crack opening is notably small, indicating the low impact of cracking on concrete permeability (CP) and showing that CP was increased with crack width. As a result, adding polypropylene aggregate to concrete could significantly reduce the width of crack, while adding steel fiber to concrete reduces the permeability of cracked concrete compared to normal concrete which may result in a minor crack on CP.