M. Mohana Rao,T. Prasad Rao,S.S. Tulasi Ram,B. P. Singh 대한전기학회 2008 Journal of Electrical Engineering & Technology Vol.3 No.1
In a gas insulated substation (GIS), Very Fast Transient Over-voltages (VFTOs) are generated due to switching operations and ground faults. These fast transients are associated with high frequency components of the order of a few hundreds of ㎒. These transients may cause internal faults i.e., layer-to-layer faults or minor faults in a capacitively graded bushing, which is one of the important pieces of terminal equipment for GIS. In the present study, the PSPICE model has been developed to calculate the voltage distribution across the layers of 420 ㎸ graded bushing for high frequency pulses of rise time I to 50 ㎱, which simulate the VFTO. For this simulation, an equivalent electrical network of bushing with different equivalent layers has been considered. The effect of different equivalent layers modeling circuits on the non-uniform voltage factor has been analysed. The influence of copper strip inductance on voltage distribution across layers has also been analysed for various rise times of high frequency transients. Finally, the leakage current of the bushing is calculated for evaluating the bushing condition under these transients.
M. Mohana Rao,S. Satyanarayana,S. Vinay Kumar,H.S. Jain 대한전기학회 2010 Journal of Electrical Engineering & Technology Vol.5 No.4
Gas-insulated transmission lines (GITL) are valued as technological solutions in hydropower stations due to their enormous power handling capabilities. The performance of GITL is a function of the size of metallic particles inside the gas-insulated chamber. Electrostatic field (E-field) enhancement is a common phenomenon in gas-insulated lines due to these metallic particles. In this study, the E-field enhancement factor is calculated by considering metallic particles at various locations in the gas-insulated line/bus section, such as high-tension (HT) conductor, high-voltage shields, support insulator, and inner surface of grounded enclosure. For this purpose, a two-dimensional model based on finite element (FE) method is developed. The length of the metallic particle is in the range of 1 to 10 ㎜ while the diameter is between 1 to 3 ㎜. E-field enhancement is also computed for various particle configurations of the gas-insulated system, with focus on dielectric coating made of epoxy on HT conductor and inner surface of grounded enclosure.
Rao, M. Mohana,Satyanarayana, S.,Kumar, S. Vinay,Jain, H.S. The Korean Institute of Electrical Engineers 2010 Journal of Electrical Engineering & Technology Vol.5 No.4
Gas-insulated transmission lines (GITL) are valued as technological solutions in hydro-power stations due to their enormous power handling capabilities. The performance of GITL is a function of the size of metallic particles inside the gas-insulated chamber. Electrostatic field (E-field) enhancement is a common phenomenon in gas-insulated lines due to these metallic particles. In this study, the E-field enhancement factor is calculated by considering metallic particles at various locations in the gas-insulated line/bus section, such as high-tension (HT) conductor, high-voltage shields, support insulator, and inner surface of grounded enclosure. For this purpose, a two-dimensional model based on finite element (FE) method is developed. The length of the metallic particle is in the range of 1 to 10 mm while the diameter is between 1 to 3 mm. E-field enhancement is also computed for various particle configurations of the gas-insulated system, with focus on dielectric coating made of epoxy on HT conductor and inner surface of grounded enclosure.
Rao, M. Mohana,Thomas, M. Joy,Singh, B.P. The Korean Institute of Electrical Engineers 2007 Journal of Electrical Engineering & Technology Vol.2 No.3
The transient fields generated during switching operations in a Gas Insulated Substation (GIS) are associated with high frequency components in the order of few tens of MHz. These transient fields leak into the external environment of the gas-insulated equipment and can interfere with the nearby electronics. Measurements of the transient fields are thus required to characterise the interference caused by switching phenomena in such substations. In view of the above, E-field emission measurement during a switching operation has been carried out for a 245 kV GIS model, using a resonant dipole antenna and D-dot sensor. The characteristics of the E-fields i.e., frequency spectra and their levels have been analysed and are reported in the paper. Suitability of the measurements has been confirmed by comparing frequency spectra of the measured and computed transient fields.
M. Mohana Rao,M. Joy Thomas,B. P. Singh 대한전기학회 2007 Journal of Electrical Engineering & Technology Vol.2 No.3
The transient fields generated during switching operations in a Gas Insulated Substation (GIS) are associated with high frequency components in the order of few tens of ㎒. These transient fields leak into the external environment of the gas-insulated equipment and can interfere with the nearby electronics. Measurements of the transient fields are thus required to characterise the interference caused by switching phenomena in such substations. In view of the above, E-field emission measurement during a switching operation bas been carried out for a 245 ㎸ GIS model, using a resonant dipole antenna and D-dot sensor. The characteristics of the E-fields i.e., frequency spectra and their levels have been analysed and are reported in the paper. Suitability of the measurements has been confirmed by comparing frequency spectra of the measured and computed transient fields.
Rao, M.Mohana,Rao, T. Prasad,Ram, S.S. Tulasi,Singh, B.P. The Korean Institute of Electrical Engineers 2008 Journal of Electrical Engineering & Technology Vol.3 No.1
In a gas insulated substation (GIS), Very Fast Transient Over-voltages (VFTOs) are generated due to switching operations and ground faults. These fast transients are associated with high frequency components of the order of a few hundreds of MHz. These transients may cause internal faults i.e., layer-to-layer faults or minor faults in a capacitively graded bushing, which is one of the important pieces of terminal equipment for GIS. In the present study, the PSPICE model has been developed to calculate the voltage distribution across the layers of 420kV graded bushing for high frequency pulses of rise time 1 to 50ns, which simulate the VFTO. For this simulation, an equivalent electrical network of bushing with different equivalent layers has been considered. The effect of different equivalent layers modeling circuits on the non-uniform voltage factor has been analysed. The influence of copper strip inductance on voltage distribution across layers has also been analysed for various rise times of high frequency transients. Finally, the leakage current of the bushing is calculated for evaluating the bushing condition under these transients.
M. Mohana Rao,P.Dharani,T. Prasad Rao 대한전기학회 2009 Journal of Electrical Engineering & Technology Vol.4 No.1
In a Gas Insulated Substation (GIS), Very Fast Transients (VFTs) are generated mainly due to switching operations. These transients may cause internal faults, i.e., layer-to-layer faults in a capacitively graded bushing as it is one of the most important terminal equipment for GIS. The healthiness of the bushing is generally verified by measuring its leakage current. However, the change in current magnitude / pattern is only marginal for different types of fault conditions. Leakage current monitoring (LCM) systems generate large amounts of data and computer aided interpretation of defects may be of great assistance when analyzing this data. In view of the above, ANN techniques have been used in this study for identification of these minor faults. A single layer perceptron network, a two layer feed-forward back propagation network and cascade correlation (CC) network models are used to identify interlayer faults in the bushing. The effectiveness of the CC network over perceptron and back propagation networks in identification of a fault has been analysed as part of the paper.
Rao, M.Mohana,Dharani, P.,Rao, T. Prasad The Korean Institute of Electrical Engineers 2009 Journal of Electrical Engineering & Technology Vol.4 No.1
In a Gas Insulated Substation (GIS), Very Fast Transients (VFTs) are generated mainly due to switching operations. These transients may cause internal faults, i.e., layer-to-layer faults in a capacitively graded bushing as it is one of the most important terminal equipment for GIS. The healthiness of the bushing is generally verified by measuring its leakage current. However, the change in current magnitude/pattern is only marginal for different types of fault conditions. Leakage current monitoring (LCM) systems generate large amounts of data and computer aided interpretation of defects may be of great assistance when analyzing this data. In view of the above, ANN techniques have been used in this study for identification of these minor faults. A single layer perceptron network, a two layer feed-forward back propagation network and cascade correlation (CC) network models are used to identify interlayer faults in the bushing. The effectiveness of the CC network over perceptron and back propagation networks in identification of a fault has been analysed as part of the paper.
Mandava Mohana Rao,M Joy Thomas,B.P. Singh 대한전기학회 2007 Journal of Electrical Engineering & Technology Vol.2 No.3
The transient fields generated during switching operations in a Gas Insulated Substation(GIS) are associated with high frequency components in the order of few tens of MHz. These transient fields leak into the external ennearby electronics. Measurements of the transient fields are thus required to characterise the interference caused by switching phenomena in such substations. In view of the above, E-field emission measurement during a switching operation has been carried out for a 245 kV GIS model, using a resonant dipole antenna and D-dot sensor. The characteristics of the E-fields i.e., frequency spectra and their levels have been analysed and are reported in the paper. Suitability of the measurements has been confirmed by comparing frequency spectra of the measured and computed transient fields.