http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
도시철도역사의 에너지 소요량 평가를 위한 BIM 기반 시뮬레이션 개발에 관한 기반연구
강규민(Gyumin Kang),강기남(Kinam Kang) 대한설비공학회 2016 대한설비공학회 학술발표대회논문집 Vol.2016 No.6
Recently, global warming and environmental pollution issues arose worldwide. Policies related with energy building have been developed in the field of architecture, for example Green BIM based design became essential step. Also, because of limitation of ground surface area, high rise or underground buildings arose. Urban railroad stations are typical underground buildings. By this reason, it is necessary to analyze characteristics of urban railroad station. Accordingly, this study will review the trend of Green BIM and urban railroad station. In this paper, propose the concept of BIM based building energy performance assessment for urban railroad station.
이은주(Eun-Ju Lee),강기남(Kinam Kang),남현민(Hyun-min Nam),이동규(Dong Kyu Lee),이병두(Byoungdoo Lee) 대한설비공학회 2017 대한설비공학회 학술발표대회논문집 Vol.2017 No.6
본 연구는 태양열 시스템 내 급탕부분 성능 개선을 목적으로 시스템 내 주요 설비기기인 펌프의 변속제어 알고리즘 작성을 통해 태양으로부터 취득된 열량을 효율적으로 이용하고자 하였다. 이에, 기존 냉난방 목적으로 구축된 시스템을 개선하여 별도의 급탕 라인을 구축하고 펌프 교체를 통해 해당 작성 알고리즘을 검증 하였다. 여기서 펌프 알고리즘은 시스템이 가지고 있는 불확실성을 정량화하여 판단이 가능한 Fuzzy 알고리즘을 이용하였으며, 실증 실험은 별도의 냉난방 부하가 적은 중간기에 시행하였다. 실증 기간 중 급탕이외의 통제변수는 고려하지 않았다. 실증 결과 본 연구에서 제안한 알고리즘을 이용하여 시스템 운전 시 기존 정속운전 대비 약 16% 향상되었으며, 소비 전력량도 약 28% 절감 가능하였다.
이은주(Eun-Ju Lee),강기남(Kinam Kang),남현민(Hyun-min Nam),이병두(Byoungdoo Lee) 대한설비공학회 2019 대한설비공학회 학술발표대회논문집 Vol.2019 No.-
본 연구에서는 그린리모델링 지원 사업을 위한 노후주택 선정 시 분석에 사용되는 Data의 실측의 중요성에 대하여 확인하고자 하였다. 노후주택의 경우 에너지성능 평가 프로그램 입력에 필요한 Data의 타당한 근거 사용되는 데이터 확보가 쉽지 않다. 이에 벽체, 창호 등의 열관류율 실측과 거주자 인터뷰, 전기/가스 고지서를 근거로 한 Data 사용시 Case별 에너지 소요량을 비교하였다. Case별 차이값은 최소 4%에서 50%이상 발생하였으며 이는 향후 노후주택의 그린리모델링 사업의 확장을 위해서는 노후주택 Data에 대한 표준값 제공이나 타당성 근거에 대한 기준이 명확해야할 것으로 판단된다.
실증을 통한 태양열 이용 흡착식 냉동기의 운전 특성 분석
이동규(Dong Kyu Lee),강기남(Kinam Kang),이은주(Eun-Ju Lee),남현민(Hyun-min Nam),이병두(Byoungdoo Lee) 대한설비공학회 2017 대한설비공학회 학술발표대회논문집 Vol.2017 No.6
This study aimed to verify capacity of the adsorption chiller under specific circumstances. Solar irradiation in South Korea is below average irradiation levels of the worldwide. Also, solar collecting areas over office and housing buildings in South Korea are not enough to make high temperature operating with solar thermal energy. Therefore, the small size of adsorption chiller is adaptable for dealing with solar thermal cooling system. The targeted zone is the lobby of first floor in Green Smart Innovation Center located in Mabuk-dong, Yong-ing si, South Korea. From September to October, four parameters are determined to verify performances of the adsorption chiller. The average radiation and cooling temperature of adsorption chiller are approximately 12.194kW and 55.58°C, and the average COPth is approximately 0.605. Therefore, small capacity of adsorption chiller is adaptable for cooling under certain restricted circumstances such as low levels of solar radiation and small collecting area. Also, domestic solar thermal system using adsorption chiller with respect using not high temperature has much great advantages of energy compared to without using middle-high temperature heats. Low cost analysis of using adsorption chiller has to be researched in next steps.
에너지절감을 위한 실내 온열환경 Adaptive Model의 검토
송두삼(Doosam Song),강기남(Kinam Kang),가토신스케(Shinsuke Kato) 한국생활환경학회 2007 한국생활환경학회지 Vol.14 No.3
The purpose of this study is to develop the air-conditioning system that adopts the adaptive model as an indoor climate control logic for energy saving. The adaptive model using the ability of human thermal adaptation could be expected to alleviate the indoor set-point temperature compared with the existing heat-balance model. Especially, in case of hybrid air-conditioning system coupled with natural ventilation and heating/cooling system, the adaptive model can be described the thermal comfort of inhabitant who stay at hybrid system controlled buildings with high accuracy. In this paper, the concept of adaptive model described and the results of a continuous measurement on the actual thermal experiences and behaviors of thermal adaptation for office worker reported.