http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Technical Analysis of Clearwell in Water works using CF
Jinhong Jung,Gyewoon Choi 보안공학연구지원센터 2016 International Journal of u- and e- Service, Scienc Vol.9 No.3
The purpose of this study was to evaluate retention time distribution and flow line clearwell in water works using computational fluid dynamics. With the finite volume method using the computational fluid dynamics (CFD), a technical diagnosis of clearwell in the water purification process was performed using an unstructured hexahedral grid system. A vector simulation showed stagnation for over 400 seconds at the circulation areas. Where clearwell have an average flow rate, a vector analysis at a height of 1.0 m showed a normal flow downstream. However, some sections of the L-shaped rear section at the left bottom of Clearwell No. 1 partially had the vortex that could cause stagnation. An analysis of flow speed contour line showed that a row of dividers in clearwell partially served as partitions. The results of the analysis can be used as basic data for the creation of alternatives such as the installation of supplementary training walls within clearwell.
Information and Communication Technologies for Smart Water Grid Applications
Ballhysa Nobel,Gyewoon Choi,변성준 한국인터넷방송통신학회 2019 Journal of Advanced Smart Convergence Vol.8 No.2
The use of Information and Communication Technologies (ICT) is the key to operate a change from the traditional manual reading of water meters and sensors to an automated system where high frequency data is remotely collected and analyzed in real time, one of the main components of a Smart Water Grid. The recent boom of ICT offers a wide range of both wired and wireless technologies to achieve this objective. We review and present in this article the most widely recognized technologies and protocols along with their respective advantages, drawbacks and applicability range which can be Home Area Network (HAN), Building Area Network (BAN) or Local/Neighborhood Area Network (LAN/NAN). We also present our findings and we give recommendations on the application of ICT in Smart Water Grids and future work needed.
Information and Communication Technologies for Smart Water Grid Applications
Ballhysa, Nobel,Choi, Gyewoon,Byeon, Seongjoon The Institute of Internet 2019 International journal of advanced smart convergenc Vol.8 No.2
The use of Information and Communication Technologies (ICT) is the key to operate a change from the traditional manual reading of water meters and sensors to an automated system where high frequency data is remotely collected and analyzed in real time, one of the main components of a Smart Water Grid. The recent boom of ICT offers a wide range of both wired and wireless technologies to achieve this objective. We review and present in this article the most widely recognized technologies and protocols along with their respective advantages, drawbacks and applicability range which can be Home Area Network (HAN), Building Area Network (BAN) or Local/Neighborhood Area Network (LAN/NAN). We also present our findings and we give recommendations on the application of ICT in Smart Water Grids and future work needed.
Hyun Min KWAK(곽현민),Myeunghoi KWON(권명회),Gyewoon CHOI(최계운),Yoonseok JUNG(정윤석),Changhwan JUNG(정창환),Kiuha PARK(박규하),Okjae SOHN(손옥재),Junhyong KIM(김준형) 한국산학기술학회 2014 한국산학기술학회논문지 Vol.15 No.1
오폐수 처리에 있어서 용존산소량을 장기간, 연속측정이 가능한 DO 센서의 개발이 요구되어, 형광검출 특성을 이용한 광학식 DO 센서를 개발하고 특성을 분석하였다 (OS-100, 글로벌광통신주식회사). 형광 센서막은 GA를 이용하여 졸-겔 방법을 이용하여 Ru(Dpp)3 2+ (tris(4,7diphenyl-1, 10-phenanthroline) ruthenium(II)) 형광물질을 제작하였고, 용액과 혼 합하여 스프레이 방법으로 석영기판위에 증착하였다. 증착된 형광막은 용존산소 농도 3 mg/L에서 10 mg/L 사이의 넓은 영역에서 ± 1% 이하의 오차를 보였다. 제작된 광학식 DO 센서의 성능평가를 위하여 대구염색단지의 오폐수처리장 폐수 의 실시간 용존산소를 장기간 측정하였다. 6개월간의 장기간에 걸쳐 실시간 측정된 용존산소의 결과는 염색공단 폐수의 악조건 하에서도 ± 2% 이하의 오차를 나타내었다. We developed and evaluated a fluorescence-based optical DO sensor (OS-100, Global Optical Communication Ltd., Korea) for long-term monitoring of the dissolved oxygen concentration in waste water treatment. Fluorescent sensing membrane containing Ru(Dpp)3 2+ (tris(4,7diphenyl-1, 10-phenanthroline) ruthenium(II)) was prepared with GA sol-gel matrix and coated on a quartz plate by sprayed method. Properties of sensor film exhibit deviation about ±1% under wide range of DO concentration from 3 to 10. The developed optical DO sensor was actually mounted in waste water from dyeing industry and successfully applied for on-line DO monitoring. Online monitoring results showed the changes of DO concentrations in wastewater treatment processes with accuracy better than ±2% during the 6 months measurements period in vicious environmental conditions.
이태우 ( Taewoo Lee ),우원희 ( Wonhee Woo ),박윤식,최계운 ( Gyewoon Chol ) 한국농공학회 2018 한국농공학회 학술대회초록집 Vol.2018 No.-
도시화로 인해 녹지면적과 투수면적이 감소하고 이로 인해 홍수발생시 유출이 지연되지 못하고 관거를 통해 빠르게 하천에 도달하는 집중호우가 최근 증가하고 있다. 기후변화 시나리오에 따르면, 2020년까지 현재보다 고온현상이 2∼6배 증가하고, 80mm이상의 비가 내리는 호우일수가 60%이상 증가할 것으로 예상되고 있다. 따라서 도시계획 시 자연상태의 물순환체계를 유지함과 동시에 빗물을 관리하는 저영향개발(LID, Low Impact Development)를 정부에서 추진하고 있다. 또한 빗물의 침투 및 저류, 이용을 목적으로 한 친환경적 관리방안에 관심이 증가함에 따라 도시개발에 있어 LID를 적용하는 추세이다. 그러나 구체적인 실행방안에 대한 매뉴얼 또는 가이드라인이 부족하고 실제 도심지 유역에 대한 사례 및 효과검증 등이 미비한 실정으로 LID를 적용하기에는 많은 한계점이 있다. 이에 본 연구에서는 실제유역을 바탕으로 LID적용에 따른 유출저감 및 침투증가량을 예측하여 체계적인 접근방법을 제시하고, 실제유역을 바탕으로 한 효과검증을 실시하고자 한다. 또한 Mock up을 이용한 투수성포장의 실험적 분석을 통해 유출 및 침투효과를 검토하고, 침투성능이 우수한 LID시설을 선정하고 평가하였으며, 투수성포장의 성능평가 도출 및 설치대안을 제시하기 위하여 계획 강우에 따른 유출침투 분석 및 평가(수문학적평가), 교통기능, 미관개선, 기후변화 분석 및 평가(기대효과평가)를 실시하였다.
권용현(Gwon, Yonghyeon),손경환(Son, Kyunghwan),이경도(Lee, Kyoungdo),최계운(Choi, Gyewoon) 한국방재학회 2020 한국방재학회논문집 Vol.20 No.2
This study aimed to develop a water balance model capable of daily analysis of the water supply situation in a multi-composite area, evaluate the utility of the model, and conduct a water balance analysis. The multi-composite water balance model, which was developed to determine the daily water balance in an area, includes five modules: Weather data build and area mean data, Rainfall-runoff analysis, Benefit area and demand estimation, Reservoir water balance analysis, and River basin water balance analysis. The study selected eight cities in northwestern Chungcheongnam-do in Korea as target areas and evaluated the utility of the water balance model. Further, the study used observation and model simulation data for its analysis, which found a high degree of accuracy as well as correlation. In addition, daily water balance analysis was conducted to estimate the potential supply, demand, supply, shortage, surplus supply, and shortage days in the river basin, while the ratio of shortage to demand was also determined to identify areas vulnerable to drought. In the future, it will be possible to establish drought countermeasures and facility operation plans by identifying areas with water supply vulnerability using the developed model. 본 연구는 다중복합지역에서의 물공급 현황을 고려한 일단위의 체계적인 분석이 가능한 물수지 모델을 개발하고, 모델의 활용성 평가 및 물수지 분석을 진행하는데 목적이 있다. 다중복합 물수지 모델은 기상자료 구축 및 유역평균값 산정, 강우-유출분석, 수혜면적 및 수요량 추정, 저수지 물수지 분석, 하천유역 물수지 분석의 5개 모듈을 활용하여 일단위 물수지를 파악할 수 있도록 개발하였다. 개발된 모델은 충남 서북부 8개 시·군을 대상지역으로 선정하여 물수지 모델의 활용성 평가 및 분석을 진행하였다. 관측자료와 모델분석결과를 활용하여 정확도를 평가한 결과, 대부분 정확도가 좋게 산정되어 활용성이 높은 것으로 확인되었다. 또한, 일단위 물수지 분석을 진행하여 하천유역의 잠재공급량, 공급량, 부족량, 잉여공급량과 부족일수를 분석하고, 수요량 대비 부족량 비율을 검토하여 가뭄 취약지역을 파악하였다. 향후 개발된 모델을 활용하여 물공급 취약지역을 조기에 파악하여 가뭄 대책 및 시설물 운영 방안 수립이 가능할 것으로 판단된다.