http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
박찬진(Chan-Jin Park) 한국환경관리학회 2007 環境管理學會誌 Vol.13 No.2
인천지역의 최근 수년간 대기환경 추이를 파악하고 향후 대기질 개선 방안을 제시하기 위하여 수년간 기준성 오염물질을 대상으로 대기질의 경향을 분석하고 문제점 파악 및 개선방안을 논의하였다. 아울러 시민들의 대기환경에 대한 체감 오염 상태를 파악하기 위하여 설문조사를 실시하고 이에 대한 결과를 토대로 향후 인천지역의 대기질을 보다 효과적으로 개선할 수 있는 정책 방안을 다각도로 제시하고자 하였다. To investigate the tendency of air quality in recent years and to suggest the solution methods of air quality improvement, the trends of air quality was analyzed & discussed in terms of standard air pollutants and the problems with the methods of solution were discussed. The questions were asked to general citizen to understand the state of feeling air pollution and the administrative methods were suggested to improve air quality more effectively.
공압 구동형 초소형 벌룬 액추에이터의 변형에 따른 PDMS 탄성체의 표면 점착력 측정
박찬진(Chan-Jin Park),서영호(Young-Ho Seo),김병희(Byeong-Hee Kim),김광섭(Kwang-Seop Kim),김재현(Jae-Hyun Kim) 한국생산제조학회 2010 한국공작기계학회 추계학술대회논문집 Vol.2010 No.-
Transfer printing process is suitable for high-performance flexible electronics since it can incorporate high temperature process without sacrificing flexibility[1,2]. One of the key elements in transfer printing process is an elastomeric stamp with conformal contact and adjustable adhesion with target devices. In this study, we developed a new concept of controllable adhesion mechanism. This concept is realized by fabricating Micro Balloon Actuator (MBA) array on the surface of a elastomeric stamp and the MBA array is controlled by air pressure. In order to validate the proposed concept, we fabricated a MBA array on a PDMS stamp using photolithography and molding process and the adhesion characteristic of the PDMS stamp with the MBA array was measured with varying air pressure using a micro-tribometer. The adhesion force between the PDMS stamp and silica lens slightly increased with the increase of air pressure under a range of 0~80㎪. Under a pressure range of 80~200㎪, the adhesion force rapidly decreased with the increase of air pressure. We also observed that the adhesion force was saturated when the applied air pressure was larger than 200 ㎪. It is noted that the adhesion force between the PDMS stamp and silica lens can be reduced approximately 80% from the original adhesion force under a preload of 50mN and air pressure of 220㎪, and was inversely proportional to the stiffness of PDMS stamp.
국가 보안관리체계 기준에 따른 국가과학기술연구망의 보안관리 구조 설계연구
박찬진(Park Chan Jin) 한국통신학회 2022 한국통신학회 학술대회논문집 Vol.2022 No.2
본 논문은 주요정보통신기반시설로 지정 받은 과학기술연구망(kREONET)에서 주요정보통신기반 시설 보호지침의 요구사항을 만족하는 과학기술연구망 관리망 설계에 관한 연구로 L2VPN을 활용한 전용 폐쇄망을 구축하고 광장비를 통한 암호화, NAC을 이용한 장비 인증, 접근통제 시스템을 활용한 사용자 인증, 내부 사용자 감사 등의 기능을 이용하여 보안성을 강화하는 방안에 대한 설계 및 구축을 통해 안전한 과학기술연구망 운영 환경을 추축하려 한다.