RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • On Board Imager (OBI)를 이용한 Setup Error 분석에 대한 연구

        김종덕,이행오,유재만,지동화,송주영,Kim, Jong-Deok,Lee, Haeng-O,You, Jae-Man,Ji, Dong-Hwa,Song, Ju-Young 대한방사선치료학회 2007 대한방사선치료학회지 Vol.19 No.1

        Purpose: The accuracy and advantages of OBI(On Board Imager) against the conventional method like film and EPID for the setup error correction were evaluated with the analysis of the accumulated data which were produced in the process of setup error correction using OBI. Materials and Methods: The results of setup error correction using OBI system were analyzed for the 130 patients who had been planned for 3 dimensional conformal radiation therapy during March 2006 and May 2006. Two kilo voltage images acquired in the orthogonal direction were fused and compared with reference setup images. The setup errors in the direction of vertical, lateral, longitudinal axis were recorded and calculated the distance from the isocenter. The corrected setup error were analyzed according to the lesion and the degree of shift variations. Results: There was no setup error in the 41.5% of total analyzed patients and setup errors between 1mm and 5mm were found in the 52.3%. 6.1% patients showed the more than 5mm shift and this error were verified as a difference of setup position and the movement of patient in a treatment room. Conclusion: The setup error analysis using OBI in this study verified that the conventional setup process in accordance with the laser and field light was not enough to get rid of the setup error. The KV images acquired using OBI provided good image quality for comparing with simulation images and much lower patients' exposure dose compared with conventional method of using EPID. These advantages of OBI system which were confirmed in this study proved the accuracy and priority of OBI system in the process of IGRT(Image Guided Radiation Therapy).

      • CBCT을 이용한 ExacTrac 6D 영상유도방사선치료법의 정확도 평가

        박호춘,김효중,김종덕,지동화,송주영,Park, Ho Chun,Kim, Hyo Jung,Kim, Jong Deok,Ji, Dong Hwa,Song, Ju Young 대한방사선치료학회 2016 대한방사선치료학회지 Vol.28 No.2

        ExacTrac 6D couch를 이용한 영상유도 방사선 치료의 정확도를 검증하기 위하여 여섯 개의 방향의 오차 값을 임의로 부여하여 교정 한 후 CBCT 이미지와 비교 분석하여 ExacTrac의 정확도를 평가 하고자 하였다. Rando head Phantom의 치료좌표 값을 X, Y, Z 방향으로 이동시킨 Translationgroup과 pitch, Roll, Yaw방향으로 이동시킨 Rotationgroup으로 나누어 교정하였다. 교정 수치는 couch의 여섯 개의 방향으로 복합적으로 상호 작용하여 이동 하였다. 교정 값은 최소 1mm, 최대 23mm까지 다양하게 나타났다. 치료좌표로 수정된 Phantom를 CBCT 촬영한 이미지와 3D/3D matching 오차 값의 분석에서는 Rotation group에서 높은 오차 값이 나타났다. CBCT로 교정된 치료좌표 오차 값에 대한 선량분포의 비교에서는 정상조직에 선량 제한치 값은 처방선량에 충족되었으며 종양조직의 선량 균질성 지표인 PHI, PCI 값은 Rotation group에서 저 선량 분포영역이 다소 높음으로 나타났다. 본 연구에서는 ExacTrac 6D couch 의 정확도에 대한 평가를 CBCT를 이용하여 검증해 보았다. 단편적인 이동에 대한 오차 값은 비교적 정확한 교정 능력을 갖추고 있었지만, couch에 각이 들어가는 이동에서는 부정확한 교정 수치를 보였다. 환자의 체위가 Rotation방향으로 많은 변화가 예상되어지거나 ExacTrac 교정하였을 때 pitch, Roll, Yaw값의 오차가 크게 나타나면 CBCT 영상유도를 시행하여 정확히 치료 좌표를 교정하여 예상치 못한 부작용을 최소화해야 된다고 여겨진다. To verify the accuracy of the image guided radiotherapy using ExacTrac 6D couch, the error values in six directions are randomly assigned and corrected and then the corrected values were compared with CBCT image to check the accurateness of ExacTrac. The therapy coordination values in the Rando head Phantom were moved in the directions of X, Y and Z as the translation group and they were moved in the directions of pitch, roll and yaw as the rotation group. The corrected values were moved in 6 directions with the combined and mutual reactions. The Z corrected value ranges from 1mm to 23mm. In the analysis of errors between CBCT image of the phantom which is corrected with therapy coordinate and 3D/3D matching error value, the rotation group showed higher error value than the translation group. In the distribution of dose for the error value of the therapy coordinate corrected with CBCT, the restricted value of dosage for the normal organs in two groups meet the prescription dose. In terms of PHI and PCI values which are the dose homogeneity of the cancerous tissue, the rotation group showed a little higher in the low dose distribution range. This study is designed to verify the accuracy of ExacTrac 6D couch using CBCT. It showed that in terms of the error value in the simple movement, it showed the comparatively accurate correction capability but in the movement when the angle is put in the couch, it showed the inaccurate correction values. So, if the body of the patient is likely to have a lot of changes in the direction of rotation or there is a lot of errors in the pitch, roll and yaw in ExacTrac correction, it is better to conduct the CBCT guided image to correct the therapy coordinate in order to minimize any side effects.

      • 양자 특성 기반 칩을 활용한 엔트로피 소스 모델 수립 방법에 관한 연구

        김대형(Dae-Hyung Kim),김주빈(Jubin Kim),지동화(dong-Hwa Ji) 한국정보통신학회 2021 한국정보통신학회 종합학술대회 논문집 Vol.25 No.2

        5세대 이후의 이동통신 기술은 초고속, 초연결, 초저지연 등을 요구하고 있다. 이 중, 안전한 초연결의 기술적 요구사항을 만족하기 위해서는 IoT 서비스의 말단에 해당하는 저사양 IoT 기기들도 고사양 서버와 동일한 수준의 보안 기능을 제공할 수 있어야 한다. 이러한 보안 기능을 수행하기 위하여 암호알고리즘에서 필요한 정도의 안전성을 가진 암호키들이 요구되고, 암호키는 보통 암호학적 난수 발생기로부터 생성된다. 이때 난수 생성을 위해서는 좋은 잡음원들이 필요한데, 저사양 기기 환경 특성상 충분한 잡음원을 확보하기 어렵기 때문에 TRNG와 같은 하드웨어 난수 발생기를 사용한다. 이 논문에서는 방사성 동위원소의 붕괴를 예측할 수 없다는 양자의 특성을 기반으로 한 칩을 사용하였으며, 이 칩이 출력하는 신호를 기반으로 이진 비트열 형태의 엔트로피 소스를 얻는 여러 방법(TRNG)을 제시하였다. 또한, 각각의 TRNG에서 출력된 값의 엔트로피에 대해 NIST SP 800-90B 테스트를 이용하여 각 방법에 대한 엔트로피 양을 비교하였다. Mobile communication technology after 5th generation requires high speed, hyper-connection, and low latency communication. In order to meet technical requirements for secure hyper-connectivity, low-spec IoT devices that are considered the end of IoT services must also be able to provide the same level of security as high-spec servers. For the purpose of performing these security functions, it is required for cryptographic keys to have the necessary degree of stability in cryptographic algorithms. Cryptographic keys are usually generated from cryptographic random number generators. At this time, good noise sources are needed to generate random numbers, and hardware random number generators such as TRNG are used because it is difficult for the low-spec device environment to obtain sufficient noise sources. In this paper we used the chip which is based on quantum characteristics where the decay of radioactive isotopes is unpredictable, and we presented a variety of methods (TRNG) obtaining an entropy source in the form of binary-bit series. In addition, we conducted the NIST SP 800-90B test for the entropy of output values generated by each TRNG to compare the amount of entropy with each method.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼