http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
이훈구(Lee Hoon-Goo),최권희(Choi Kwon-Hee),조용균(Jo Yong-Gyun),이영호(Lee Young-Ho),황현철(Hwang Hyeon-Chyeol) 대한전기학회 2009 대한전기학회 학술대회 논문집 Vol.2009 No.4
It is a proven fact with the opening of the Seoul metro line number 1 in 1974 traffic congestion on the roads has decreased and the efficiency of people transportation in general has greatly been enhanced in the downtown and surrounding areas of Seoul. Even today construction of new subway lines are under way and many more are being planned due to the easy access to stations, short waiting and average traval times, compared with personal vehicles, contributing to the efficiency of the public transportation systems that are linking the downtown areas and also the intercity systems in moving passengers during rush hour and times of special event. Since the labour costs of the train operator in any large city based subway system accounts for a major part of the operating costs per kilometer and to ensure cost efficient operations, especially during non-peak hours, it is necessary to implement an unmanned(auto-driven) subway system. In order to implement such a system it is imperative that the on-board and wayside signalling control systems be fully automated as well. Only through proper examination of safety procedures not only by the AUGT(Automated Urban Guided Transport)system but also by all the international standards organizations involved can safely and stability be ensured.
정춘병,전기영,이훈구,한경희,Chun, Choon-Byeon,Jeon, Kee-Young,Lee, Hoon-Goo,Han, Kyung-Hee 한국조명전기설비학회 2004 조명·전기설비학회논문지 Vol.18 No.6
The author present a modified multi-loop algorithm including feedforward for controlling a 55kW step down chopper in the power supply of Maglev. The control law for the duty cycle consists of three terms. The first is the feedforward term. which compensates for variations in the input voltaga. The second term consists of the difference between the slowly moving inductor current and output current. The third term consists of proportional and integral terms involving the perturbation in the output voltage. This perturvation is derived by subtracting the desired output voltage from the actual output voltage. The proportional and integral action stabilizes the system and minimizes output voltage error. In order to verify the validity of the proposed multi-loop controller, simulation study was tried using Matlab simulink 본 논문은 자기부상열차용 전원의 문제점을 개선시키기 위해서 다중루프 제어기를 제시하였다. 제시된 제어기는 3개의 부분으로 구성되어 있다. 첫 번째는 입력전압의 변동에 대하여 보상할 수 있는 Feed Forward제어기이며 두 번째는 리액터 전류와 출력 전류의 차를 보상하며, 세 번째는 비례적분제어기를 사용하여 출력전압에 포함된 리플을 감소시키므로써, 안정화된 시스템을 구현하였다. 이 시스템의 특성을 확인하기 위해서 Matlab Simulink와 고성능 DSP소자인 TMS320F240을 이용하여 비교 분석하였다.
김유호(Kim You-Ho),이훈구(Lee Hoon-Goo),이수환(Lee Soo-Hwan),이영호(Lee Young-Ho),황현철(Hwang Hyeon-Chyeol) 대한전기학회 2009 대한전기학회 학술대회 논문집 Vol.2009 No.7
Recently interior of a country have been innovated driverless LRT(lightweight railway train) that has a virtue of reducion of payroll cost, decrease of headway and improvement of speed. But, if driverless LRT will be happened a accident, response capacity considerably have low. And then passenger will have feel fear. This thesis had examination a IEC 62267 : AUGT safety requirement and analyze safe facilities of the inside and outside of the country. Later on, this result will have not only increase economics, reliability, convenience and safety but also set standardization standard.