http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
도막 방수층 계면에 발생되는 수증기압에 관한 실험적 연구
신윤호(Shin Yun-Ho),윤정운(Yun Jung-Woon),문정오(Mun Jung-O),고진수(Ko Jin-Soo) 한국구조물진단유지관리학회 2006 한국구조물진단학회 학술발표회논문집 Vol.10 No.2
As a result of measuring the water vapor pressure for the surface temperature of the waterproofing layer with the fluid-applied membrane temperature based on about 10℃, which is the average temperature of Seoul, it was found that first, the fluid-applied membrane elevated up to about 40℃, and the water vapor pressure generated from the fluid-applied membrane was about 0.03N/㎟ when the surface temperature of the waterproofing layer was raised up to about 80℃. Second, when the fluid-applied membrane temperature of the waterproofing layer was raised from 30℃ to 35℃, about 0.01N/㎟ of water vapor pressure was generated, and when supplying a thermal source to raise the fluid-applied membrane temperature of the waterproofing layer from 35℃ to 40℃, approximately 0.005N/㎟ of vapor pressure was generated.
도막 방수층 계면에 발생되는 수증기압에 관한 실험적 연구
신윤호 ( Shin Yun-ho ),윤정운 ( Yun Jung-woon ),문정오 ( Mun Jung-o ),고진수 ( Ko Jin-soo ) 한국구조물진단유지관리공학회 2006 한국구조물진단유지관리공학회 학술발표대회 논문집 Vol.10 No.2
As a result of measuring the water vapor pressure for the surface temperature of the waterproofing layer with the fluid-applied membrane temperature based on about 10°C, which is the average temperature of Seoul, it was found that first, the fluid-applied membrane elevated up to about 40°C, and the water vapor pressure generated from the fluid-applied membrane was about 0.03N/㎟ when the surface temperature of the waterproofing layer was raised up to about 80°C. Second, when the fluid-applied membrane temperature of the waterproofing layer was raised from 30°C to 35 °C, about 0.01N/㎟ of water vapor pressure was generated, and when supplying a thermal source to raise the fluid-applied membrane temperature of the waterproofing layer from 35°C to 40°C, approximately 0.005N/㎟ of vapor pressure was generated.