RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 등재정보
        • 학술지명
          펼치기
        • 주제분류
        • 발행연도
          펼치기
        • 작성언어

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        The effect of resin thickness on polymerization characteristics of silorane-based composite resin

        손성애,노형미,허복,권용훈,박정길 대한치과보존학회 2014 Restorative Dentistry & Endodontics Vol.39 No.4

        Objectives: This study examined the influence of the resin thickness on the polymerization of silorane- and methacrylate-based composites. Materials and Methods: One silorane-based (Filtek P90, 3M ESPE) and two methacrylate-based (Filtek Z250 and Z350, 3M ESPE) composite resins were used. The number of photons were detected using a photodiode detector at the different thicknesses (thickness, 1, 2 and 3 mm) specimens. The microhardness of the top and bottom surfaces was measured (n = 15) using a Vickers hardness with 200 gf load and 15 sec dwell time conditions. The degree of conversion (DC) of the specimens was determined using Fourier transform infrared spectroscopy (FTIR). Scratched powder of each top and bottom surface of the specimen dissolved in ethanol for transmission FTIR spectroscopy. The refractive index was measured using a Abbe-type refractometer. To measure the polymerization shrinkage, a linometer was used. The results were analyzed using two-way ANOVA and Tukey’s test at p < 0.05 level. Results: The silorane-based resin composite showed the lowest filler content and light attenuation among the specimens. P90 showed the highest values in the DC and the lowest microhardness at all depth. In the polymerization shrinkage, P90 showed a significantly lower shrinkage than the rest two resin products (p < 0.05). P90 showed a significantly lower refractive index than the remaining two resin products (p < 0.05). Conclusions: DC, microhardness, polymerization rate and refractive index linearly decreased as specimen thickness linearly increased. P90 showed much less polymerization shrinkage compared to other specimens. P90, even though achieved the highest DC, showed the lowest microhardness and refractive index.

      • KCI등재후보

        All-in-one adhesive의 다층적용이 미세인장결합강도에 미치는 영향

        손성애,허복 大韓齒科保存學會 2004 Restorative Dentistry & Endodontics Vol.29 No.5

        The purpose of this study was to evaluate the effect of multiple application of all-in-one dentin adhesive system on microtensile bond strength using confocal laser scanning microscope and microtensile bond strength test. Flat occlusal dentin surfaces were prepared using low-speed diamond saw. In group I, Scotchbond Multipurpose (SM) was applied by manufacturer's recommendation. In group II, after Adper Prompt L-Pop was applied for 15s and light cured for 10s. the second coat was re-applied and light-cured. In group III, after light-curing the second layer. the third coat was re-applied and light-cured. Specimens bonded with a resin-composite were sectioned into resin-dentin stick for measuring the adhesive layer thickness by confocal laser scanning microscope and evaluating micro-tensile bond strength. The adhesive layers of three-step dentin adhesive system. 3 coats of Adper Prompt L-Pop had significantly thicker than SM. 2 coats of Adper Prompt L-Pop (p < 0.05). However. there was no significant differences in bond strengths between SM and 3 coats of Adper Prompt L-Pop (p > 0.05). And SM. 3 coats of Adper Prompt L-Pop had significantly higher than 2 coats of Adper Prompt L-Pop in bond strengths (p < 0.05).

      • KCI등재

        표면 전처리가 자가접착 레진의 미세인장결합강도에 미치는 영향

        손성애,박완기,이인수,허복,김형일,권용훈,박정길 대한치과재료학회 2012 대한치과재료학회지 Vol.39 No.1

        본 연구는 최근 소개된 자가 접착 저점도 레진인 Dyad flow의 법랑질 및 상아질의 치면 전처리여부에 따른 미세인장결합강도를 비교 연구하였다. 본 실험을 위해 24개의 상하악 대구치를 치면의 전처리방법에 따라 8개의 군으로 나누었다. E1,D1군은 치면의 전처리과정없이, E2군은 인산처리, D2군은 conditioning, E3,D3군에서는 Optibond All-in-one, E4,D4군에서는 Clearfil SE bond로 치면의 전처리 과정을 시행한 이후 각각 Dyad flow를 적층 충전하였다(E군; 법랑질군, D군; 상아질군). 24시간 동안 실온의 증류수에 보관한 후 각 그룹당 15개의 시편을 준비하였다. 모든 시편의 미세인장결합강도와 파절양상를 측정하여 다음의 결과를 얻었다. 제조회사의 지시에 따라 Dyad flow만을 적용한 E1군과 D1군에서는 시편을 제작하는 과정에서 모두 파절되어 미세인장결합강도를 측정할 수 없었다. 법랑질 표면 처리방법에 따른 시편의 미세인장결합강도는 E2군이 가장 낮은 값을, E3군이 가장 높은 값을 나타냈으며, E2군은 E3군과 E4군에 대하여 유의하게 낮은 값을 나타내었다(p<0.05). 상아질 표면 처리방법에 따른 시편의 미세인장결합강도는 D2군이 가장 낮은 값을, D3군이 가장 높은 값을 나타냈으며, D2군은D3군과 D4군에 대하여 유의하게 낮은 값을 나타내었다(p<0.05). 파절양상은 대부분 접착성 파절을 보였고 일부는 응집성파절을 보였다.

      • KCI등재

        Silorane 기질 복합레진에 있어 레진두께가 중합률과 미세경도에 미치는 영향

        손성애,김현철,허복,설효정,권용훈,김형일,박정길 대한치과재료학회 2012 대한치과재료학회지 Vol.39 No.1

        본 연구는 silorane을 기질로 하는 복합레진에 있어 레진의 두께에 따라 중합률과 미세경도에 미치는 영향을 비교,평가하고자 하였다. methacrylate 기질의 복합레진 (Z250, Z350; 3M ESPE, St. Paul, MN, USA)과 Silorane 기질의복합레진 (P90; 3M ESPE)을 대상으로 각각 1, 2, 3 ㎜ 두께의 시편을 제작 하였다. 각 시편의 미세경도는 Vickers hardness tester를 사용하여 200-gf 의 하중을 15초간 가한 후 측정하였고 각 시편의 중합률 측정을 위해 FTIR 분광분석기를 사용하여 중합 전후의 스펙트럼을 기록한 후, 측정값을 ANOVA와 Turkey test로 분석하고 이들의 상관관계를 분석하여 다음과 같은 결과를 얻었다. 복합레진의 기질과 관계없이 모든 레진 시편은 두께가 두꺼워질수록 중합률,미세경도는 직선적인 감소를 나타내었다(p < 0.05). 중합률, 미세경도 간에는 선형적 상관관계를 나타내었다. Silorane 기질의 복합레진은 낮은 필러함양으로 높은 중합률을 보임에도 낮은 미세경도를 보였다.

      • KCI등재
      • KCI등재

        CAD-CAM 인레이/온레이 수복을 위한 와동형성의 가이드라인

        손성애(Song Ae Son) 대한치과의사협회 2016 대한치과의사협회지 Vol.54 No.8

        Currently with the continuous development of ceramic and cementation materials, CAD-CAM(Computer-aided design/Computer-aided manufacture) restorations are becoming increasingly popular in esthetic dentistry. Preparation design is influenced by the selected restorative material, the fabrication method, and the ability to bond the restoration. For long-lasting CAD/CAM inlay/onlay restoration, clinicians should understand the basic knowledge of CAD/CAM restoration’s cavity design to obtain the fracture resistance and proper fitting margin. This article gives an overview of preparation guidelines for CAD/CAM inlay/onlay restorations.

      • KCI등재

        균열치아 진단에서 정량광형광(Quantitative Light-Induced fluorescent(QLF))장비의 활용

        손성애(Sung Ae Son) 대한치과의사협회 2024 대한치과의사협회지 Vol.62 No.1

        As social interest in health increases, interest in oral health and preservation of natural teeth are also increasing. The hard tissues in the oral cavity undergo physical changes as age increases. One of the changes is the progress of tooth cracks in natural or restored teeth. These cracks are commonly encountered in daily clinical practice but often confuse the operator due to its difficulties in diagnosis and therapeutic access. Diagnosing a cracked tooth has been a chanllenge to dental clinicians. For the diagnosis of a cracked tooth, the quantitative light-induced fluorescent (QLF) device, which is capable of detecting fluorescent reactions of the tooth with visible light (405nm), has been introduced as one of the methods for observing tooth cracks. Specific metabolites of microorganisms that penetrate through the cracks line react with specific autofluorescence to 405nm visible light emitted from the QLF device. These fluorescent image provided by the QLF helps to observe the location of the crack during the diagnosis of a cracked tooth and helps the patients dental record. The QLF images provided a magnified image as well as a fluorescent image that could identify the location of the crack existing outside the tooth, around the restoration, and inside the cavity after removal of the restoration by a simple process of capturing images. This report shows the process of diagnosis of a cracked tooth using a QLF device by observing three separate cases which can help clinicians to understand this process.

      • KCI등재

        Silorane 기질 복합레진의 색조와 두께가 중합 물성에 미치는 영향

        손성애(Sung-Ae Son),노형미(Hyoung Mee Roh),권용훈(Yong Hoon Kwon),진명욱(Myoung-Uk Jin),박정길(Jeong-Kil Park) 대한치과재료학회 2014 대한치과재료학회지 Vol.41 No.4

        The aim of this study was to evaluate the influence of the polymerization on shade and thickness of a silorane-based composite resin. A2, A3 and C2 shades of silorane ?based composite resin were selected. The number of photons were detected using the photodiode detector. The microhardness of the specimen was measured using a Vickers hardness at the different thicknesses. The degree of conversion (DC) of the specimens was determined using Fourier transform infrared spectroscopy (FTIR). To measure the polymerization shrinkage, a linometer was used. Data were statistically analyzed by ANOVA and Tukey’s test. In the subsurface, the incident light decreased exponentially. A2 group showed less light attenuation than the other groups(p<0.05). The microhardness of A2 group ranged 52.0-62.3 Hv on top and bottom surfaces, A3 and C2 groups were ranged 48.5-58.3 Hv and 51.6-61.5 Hv, respectively. In the DC, A3 group showed significantly lower when compared to A2 group(p<0.05). Polymerization shrinkage was 7.3-7.6μm and these were significantly similar regardless of the specimens(p>0.05). In conclusion, photons decreased exponentially with increasing specimen thickness. The microhardness and the DC of A3 group were significantly lower than other groups. Polymerization shrinkage had statistically similar values regardless of the groups (p<0.05).

      • KCI등재

        Influence of Resin Thickness on the Degree of Conversion and Microhardness of Silorane-based Composite Resin

        Sung-Ae Son(손성애),Hyeon-Cheol Kim(김현철),Bock Hur(허복),Hyo-Joung Seol(설효정),Yong-Hoon Kwon(권용훈),Hyung-Il Kim(김형일),Jeong-Kil Park(박정길) 대한치과재료학회 2012 대한치과재료학회지 Vol.39 No.1

        본 연구는 silorane을 기질로 하는 복합레진에 있어 레진의 두께에 따라 중합률과 미세경도에 미치는 영향을 비교, 평가하고자 하였다. methacrylate 기질의 복합레진 (Z250, Z350; 3M ESPE, St. Paul, MN, USA)과 Silorane 기질의 복합레진 (P90; 3M ESPE)을 대상으로 각각 1, 2, 3 ㎜ 두께의 시편을 제작 하였다. 각 시편의 미세경도는 Vickers hardness tester를 사용하여 200-gf 의 하중을 15초간 가한 후 측정하였고 각 시편의 중합률 측정을 위해 FTIR 분광분석기를 사용하여 중합 전후의 스펙트럼을 기록한 후, 측정값을 ANOVA와 Turkey test로 분석하고 이들의 상관관계를 분석하여 다음과 같은 결과를 얻었다. 복합레진의 기질과 관계없이 모든 레진 시편은 두께가 두꺼워질수록 중합률, 미세경도는 직선적인 감소를 나타내었다(p < 0.05). 중합률, 미세경도 간에는 선형적 상관관계를 나타내었다. Silorane 기질의 복합레진은 낮은 필러함양으로 높은 중합률을 보임에도 낮은 미세경도를 보였다.

      • KCI등재

        The Effect of Surface Pre-Treatment on the Microtensile Bond Strength of Self-Adhering Composite Resin

        Sung-Ae Son(손성애),Wan-Ky Park(박완기),In-Soo Lee(이인수),Bock Hur(허복),Hyung-Il Kim(김형일),Yong-Hoon Kwon(권용훈),Jeong-Kil Park(박정길) 대한치과재료학회 2012 대한치과재료학회지 Vol.39 No.1

        본 연구는 최근 소개된 자가 접착 저점도 레진인 Dyad flow의 법랑질 및 상아질의 치면 전처리여부에 따른 미세인장결합강도를 비교 연구하였다. 본 실험을 위해 24개의 상하악 대구치를 치면의 전처리방법에 따라 8개의 군으로 나누었다. E1,D1군은 치면의 전처리과정없이, E2군은 인산처리, D2군은 conditioning, E3,D3군에서는 Optibond All-in-one, E4,D4군에서는 Clearfil SE bond로 치면의 전처리 과정을 시행한 이후 각각 Dyad flow를 적층 충전하였다(E군; 법랑질군, D군; 상아질군). 24시간 동안 실온의 증류수에 보관한 후 각 그룹당 15개의 시편을 준비하였다. 모든 시편의 미세인장결합강도와 파절양상를 측정하여 다음의 결과를 얻었다. 제조회사의 지시에 따라 Dyad flow만을 적용한 E1군과 D1군에서는 시편을 제작하는 과정에서 모두 파절되어 미세인장결합강도를 측정할 수 없었다. 법랑질 표면 처리방법에 따른 시편의 미세인장결합강도는 E2군이 가장 낮은 값을, E3군이 가장 높은 값을 나타냈으며, E2군은 E3군과 E4군에 대하여 유의하게 낮은 값을 나타내었다(p<0.05). 상아질 표면 처리방법에 따른 시편의 미세인장결합강도는 D2군이 가장 낮은 값을, D3군이 가장 높은 값을 나타냈으며, D2군은 D3군과 D4군에 대하여 유의하게 낮은 값을 나타내었다(p<0.05). 파절양상은 대부분 접착성 파절을 보였고 일부는 응집성파절을 보였다.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼