        Performance-based Fire Protection Design of Domestic Super High-rise Buildings - Evaluation by ASET and RSET -

        노형기 한국방재학회 2011 한국방재학회논문집 Vol.11 No.2

        The Performance-based fire protection design required to construct super high-rise building is the active measure for the evaluation of fire risks and the establishment of fire protection systems on the basis of engineering analysis, which is more efficient and proper than existing prescriptive-based design. This study applied time-line analysis of RSET is required safe egress time and ASET is available safe egress time with the fire and evacuation simulation to analyze. The result of this study showed the sprinkler system increased ASET and fire detection and alarm system reduced RSET efficiently. Reduced evacuation time influences to secure the life safety. Also it is essential to maintain the fire suppression system and fire detection & alarm system properly. Database of fire movement and evacuation action program are useful for the performance-based design.

      • KCI등재

        화재경보음 감쇠에 관한 수치적 연구

        노형기,임정순 한국방재학회 2012 한국방재학회논문집 Vol.12 No.4

        This study theoretically examined domestic and overseas sound standard of fire alarm and the sounder was installed in accordance with the criteria specified in the ‘fire safety code’, and the adequacy of sound level with which fire alarm sound can be conveyed to residents were verified by numerical analysis of the sound level of the farthest location from the sounder. The sound level of fire alarm analyzed with the criteria specified in the fire safety standard about the place which is located at the farthest distance from sounder was appeared to be 36 dBA, 59 dBA and didn't satisfied from 65 dBA specified in the UK standard in evaluation model. The sound of fire alarm could accurately be conveyed when a separate sounder was installed at a room which was partitioned in order to convey the sound of fire alarm to the resident of building. In performance-based fire protection design, if sound attenuation was calculated for application, it was analyzed that damage of human life could be reduced with rapid evacuation through accurate reception of the fire alarm sound on the part of resident on the fire. Based on the result of this study, wider range of studies for the sound attenuation of fire alarm sounder would be required, and legislation regarding the spacing of the fire alarm sounder need to be revised and supplemented. 본 연구에서는 국내외의 화재경보 음향 기준을 이론적으로 고찰하고 ‘화재안전기준’에서 규정한 기준으로 음향장치를 설치하고 음향장치로부터 가장 먼 곳에서의 음향 레벨을 수치적으로 해석하여 거주자가 화재경보음을 전달 받을 수 있는 음향 레벨의 적정성을 판단하였다. 평가모델에서 음향장치로부터 가장 멀리 떨어진 장소를 화재안전기준에서 규정한 기준으로 해석한 화재경보 음향 레벨은 36 dBA 및 59 dBA로 나타나 영국 기준에서 규정한 65 dBA를 만족하지 못하였다. 화재경보 음향을 건축물의 거주자에게 전달하기 위하여 구획된 실에 별도의 음향 장치를 설치할 경우 화재경보 음향을 정확히 전달할 수 있었다. 성능위주의 소방 설계 시 음향 감쇠를 계산하여 적용하면 화재 시 거주자가 화재경보 음향을 정확히 전달받아 신속한 피난으로 인명의 피해를 줄일 수 있을 것으로 분석이 되었다. 본 연구의 결과를 토대로 하여 화재경보장치의 음향 감쇠에 대한 더많은 연구가 필요하며 또한 화재경보장치의 배치 간격을 조정하는 법규의 보완 및 개선이 필요할 것으로 판단된다.

      • KCI등재

        터널 화재 시 열감지기 작동 온도의 비교에 관한 실험적 연구

        노형기,박광영,임석빈,Roh,Hyeong-Ki,Park,Kwang-Young,Im,Seok-Been 한국방재학회 2011 한국방재학회논문집 Vol.11 No.1

        Due to the rapid development of construction technology with effective land utilization in this nation, many tunnels were and are being built across the country. However, the smoke and the heat generated from tunnel fire are the most important critical factors which may results in both massive personal injury and property damage, especially, due to the closed surrounding of the tunnel. Considering this particular nature of the tunnels, this study aims to install a fire detection system using an optic fiber cable to measure the temperature changes, compare, and analyze the resulted values with the times of temperature changes of the sensor by performing fire simulations under the same condition as a real fire test. From the results, it has been found that the temperature sensor detects a fire occurrence and generates an alarm within one minute after ignition for both a real fire test and a fire simulation alike, and also that the characteristics of temperature changes of the sensor has close relations with the speeds of the currents inside the tunnel. In addition, considering the tunnel fires can affect the evacuation efficiency and the fire extinguishing activities of the fire brigade inside the tunnel, the temperature sensor must be able to search and find the locations and directions of the fires correctly. 건설 기술 발전과 국토의 효율적인 활용으로 인하여 건설되고 있는 터널은 지하 공간과 같은 폐쇄 공간의 특성으로 화재 시발생하는 연기와 열은 인명 및 물적 피해에 영향을 주는 매우 큰 위험요소이다. 본 연구에서는 광케이블을 이용하여 온도 변화를 측정하는 화재 감지 시스템을 설치하여 감지기가 동작한 온도 변화 값 및 시간과 실 화재 실험과 동일한 조건으로 화재 시뮬레이션을 수행하여 온도센서의 온도 변화 값 및 시간을 비교, 분석하였다. 실험 결과 화재실험과 화재 시뮬레이션의 온도변화는 점화 후 1분 이내에 화재를 감지하여 신호를 경보하는 것으로 나타났으며, 화재 감지기와 시뮬레이션 온도 센서의 온도변화 특성은 터널 내부의 기류 속도와 밀접한 관계를 가지는 것으로 나타났다. 또한 터널 화재는 연기의 방향에 의해 피난과 소방대 진입에 영향을 미치므로 화재 지점과 화재 방향을 파악할 수 있어야 한다.

      • 터널 화재 시 열감지기 작동 온도의 비교에 관한 실험적 연구

        노형기,박광영,임석빈 한국방재학회 2011 한국방재학회지 Vol.11 No.1

        건설 기술 발전과 국토의 효율적인 활용으로 인하여 건설되고 있는 터널은 지하 공간과 같은 폐쇄 공간의 특성으로 화재 시발생하는 연기와 열은 인명 및 물적 피해에 영향을 주는 매우 큰 위험요소이다. 본 연구에서는 광케이블을 이용하여 온도 변화를 측정하는 화재 감지 시스템을 설치하여 감지기가 동작한 온도 변화 값 및 시간과 실 화재 실험과 동일한 조건으로 화재시뮬레이션을 수행하여 온도센서의 온도 변화 값 및 시간을 비교, 분석하였다. 실험 결과 화재실험과 화재 시뮬레이션의 온도변화는 점화 후 1분 이내에 화재를 감지하여 신호를 경보하는 것으로 나타났으며, 화재 감지기와 시뮬레이션 온도 센서의 온도변화 특성은 터널 내부의 기류 속도와 밀접한 관계를 가지는 것으로 나타났다. 또한 터널 화재는 연기의 방향에 의해 피난과소방대 진입에 영향을 미치므로 화재 지점과 화재 방향을 파악할 수 있어야 한다. Due to the rapid development of construction technology with effective land utilization in this nation, many tunnels were andare being built across the country. However, the smoke and the heat generated from tunnel fire are the most important critical fac-tors which may results in both massive personal injury and property damage, especially, due to the closed surrounding of the tun-nel. Considering this particular nature of the tunnels, this study aims to install a fire detection system using an optic fiber cable tomeasure the temperature changes, compare, and analyze the resulted values with the times of temperature changes of the sensor byperforming fire simulations under the same condition as a real fire test. From the results, it has been found that the temperaturesensor detects a fire occurrence and generates an alarm within one minute after ignition for both a real fire test and a fire sim-ulation alike, and also that the characteristics of temperature changes of the sensor has close relations with the speeds of the cur-rents inside the tunnel. In addition, considering the tunnel fires can affect the evacuation efficiency and the fire extinguishingactivities of the fire brigade inside the tunnel, the temperature sensor must be able to search and find the locations and directionsof the fires correctly.

      • 색상 및 형태 정보를 이용한 내용 기반 영상 검색 시스템의 Web 상에서의 구현

        황본우(Bon-Woo Hwang),노형기(Hyung-Ki Roh),이성환(Seong-Whan Lee) 한국정보과학회 1998 한국정보과학회 학술발표논문집 Vol.25 No.1B

        인간의 시각 시스템은 영상을 검색하거나 인식할 때 색상이나 형태, 질감과 같은 가시적인 영상의 특징에서 많은 정보를 획득한다. 그러나 현재 많은 영상 검색 시스템은 수작업에 의한 문자 정보만을 이용하여 색인함으로써 영상이 갖고 있는 고유한 특정을 이용할 수 없다는 단점이 있다. 본 논문에서는 이러한 단점을 극복하여 색상 및 형태 정보를 이용한 내용 기반 영상 검색 시스템을 제안한다. 제안된 검색 시스템의 응용 가능성을 시험하기 위해 색인 시스템과 Web 서버를 사용하여 시스템을 구현하였다. 색상에 의한 검색에서는 전체 영역 히스토그램을 이용한 방법과 공간 정보를 보존할 수 있는 부분 영역을 방법을 사용자가 선택할 수 있도록 하였다. 형태에 의한 검색은 크기, 회전, 위치 변화에 무관하도록 색인 과정에서 정규화하였다.