http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
디젤엔진 관련 Soot 부착 및 재유입에 관한 화염에서의 연구
김성근,박종인,Kim, Seong-Geun,Park, Jong-In 대한기계학회 1996 大韓機械學會論文集B Vol.20 No.8
A study of soot deposition and reentrainment was carried out both theoretically and experimentally to understand behavior of soot formed by incomplete combustion in a diesel engine. Theoretically, soot deposition on engine cylinder wall and/or piston head was studied with a stagnation point flow approximation. Soot reentrainment occurred upon exhaust gas blowdown was also studied by assuming a long-normal shear velocity distribution. Experimentally, a LPG$O_2/N_2$ flame impinging on a disk, produced by a concentric tubular burner, was chosen as deposition configuration and a shear flow unit with compressed air was installed for the study of reentrainment. For selected flame configuration, soot deposition measurements were conducted and showed that the dominant deposition mechanism was thermophoresis. Distributions of gas temperature and soot number density were estimated by combining data obtained by a B-type thermocouple with a thermophoretic transport theory. Disk temperature distributions were directly measured using a K-type thermocouple. Soot size and morphology were estimated from a TEM photograph. Ratios of soot deposit to reentrained amount were measured for a wide range of shear flow velocities, which showed that the reentrainment model was reasonable.
원전 터빈사이클 성능 데이터의 검증 모델에 의한 성능분석 기법의 개발
김성근,최광희,Kim, Seong-Geun,Choe, Gwang-Hui 대한기계학회 2000 大韓機械學會論文集B Vol.24 No.12
Verification of measurements is required for precise evaluation of turbine cycle performance in nuclear power plant. We assumed that initial acceptance data and design data of the plant could provide correlation information between performance data. The data can be used as sample sets for the correct estimation model of measurement value. The modeling was done practically by using regression model based on plant design data, plant acceptance data and verified plant performance data of domestic nuclear power plant. We can construct more robust performance analysis system for an operation nuclear power plant with this validation scheme.
부정합 감지 복제 전하 펌프를 이용한 자동 전류 보상 전하 펌프의 설계
김성근(Seong Geun Kim),김영신(Seong Geun Kim),부영건(Young Gun Pu),박준성(Joon-Sung Park),허정(Jeong Hur),이강윤(Kang-Yoon Lee) 대한전자공학회 2010 電子工學會論文誌-SD (Semiconductor and devices) Vol.47 No.2
본 논문에서는 공정, 전압, 온도 변화에도 전하 펌프의 전류부정합을 자동으로 보정하기 위한 전하 펌프 구조를 제안한다. 일반적으로 위상 동기 루프의 위상 잡음 및 스퍼 성능을 향상시키기 위해서 전하 펌프의 전류부정합을 최소화해야 한다. 전류 부정합을 보정하기 위해서 복제 전하 펌프로부터 전류 복사를 통해 어떠한 경우에도 실제 전류 차이만큼을 피드백 하도록 하는 방법을 제안하였다. 이 방법은 전하 펌프의 전류부정합을 해결하기 위한 여러 가지 방법 중에서도 상대적으로 간단한 회로로 구성할 수 있으며, 부정합 전류치를 그대로 복사하기 때문에 높은 정확도를 가진다. 기존에 제안되었던 방법들은 대부분 다이나믹 특성에 대한 성능이 부족하지만 본 논문에서 제안된 방법은 실시간으로 보정기능을 수행함으로써 다이나믹 특성에서도 우수한 성능을 가진다. 제안하는 전하 펌프는 0.13㎛ CMOS 공정으로 설계 되었으며, 면적은 100㎛ × 160㎛이다. 1.2V의 공급전압에서 0.2V ~ 1V의 출력 전압 범위를 가진다. 충전 전류와 방전 전류는 100㎂이며, PVT variation에 대한 전류 부정합은 1% 미만이다. This paper presents a charge pump architecture for correcting the current mismatch due to the PVT variation. In general, the current mismatch of the charge pump should be minimized to improve the phase noise and spur performance of the PLL. In order to correct the current mismatch of the charge pump, the current difference is detected by the replica charge pump and fed back into the main charge pump. This scheme is very simple and guarantees the high accuracy compared with the prior works. Also, it shows a good dynamic performance because the mismatch is corrected continuously. It is implemented in 0.13㎛ CMOS process and the die area is 100㎛ × 160㎛. The voltage swing is from 0.2V to 1V at supply voltage of 1.2V. The charging and discharging currents are 100㎂, respectively and the current mismatch due to the PVT variation is less than 1%.
사출성형 열가소성 폴리우레탄의 물리적 성질에 미치는 금형 온도 영향
김성근 ( Seong Geun Kim ),구엔빈칸 ( Vinh Khanh Nguyen ),이명걸 ( Ming Ji Lee ),방수진 ( Su Jin Pang ),이대수 ( Dai Soo Lee ) 한국고무학회 2004 엘라스토머 및 콤포지트 Vol.39 No.4
경도를 달리하는 에스테르계 및 에테르계 열가소성 폴리우레탄(thermoplastic polyurethane: TPU)의 사출에서 금형 온도가 물리적 성질에 미치는 영향을 조사하였다 TPU의 연질부 유리전이온도는 금형 온도 변화에 따라 거의 변화하지 않았으며, 연질부와 경질부의 상분리는 금형온도의 영향을 별로 받지 않는 것으로 판단되었다. 그러나 에스테르계와 에테르계 TPU는 종류에 관계없이 공통적으로 경도가 높은 TPU들은 금형온도를 높이는 경우 결정성, 고무상 평탄 온도영역, 인장강도가 감소하였으나, 경도가 낯은 TPU들은 오히려 결정성, 고무상 평탄 온도영역, 인장강도의 증가를 보였다. TPU의 사출 성형 금형 온도에 따른 물리적 성질의 차이를 결정성경질부의 결정화와 물리적 가교효과 차이로 해석하였다. Ester- and ether-based thermoplastic polyurethanes of different hardness were injection molded at different mold temperatures and effects of mold temperature on the physical properties of TPUs were investigated. Glass transition temperatures of soft segments of TPUs were hardly changed by mold temperatures. The phase separation of soft and hard segments of injection molded TPUs were affected little by mold temperatures. However, crystallinity of hard segments, temperature range of rubbery plateau, and tensile strength of injection molded TPUs decreased with increasing mold temperatures for TPUs of high hardness. However, injection molded TPUs of low hardness showed increases of crystallinity of hard segments, temperature range of rubbery plateau, and tensile strength with increasing mold temperatures. Different physical properties of injection molded TPUs depending on mold temperatures were attributed to different crystallization and physical crosslinking effects of hard segments.