권동진,Kweon, Dong-Jin 대한전기학회 2001 전기학회논문지C Vol.51 No.3
This paper describes an application of the on line partial discharge measurement method in operating transformer. In the operating transformer, the partial discharge signal may be superimposed by radio intereference voltage(RIV) and pulse shaped noise signals generated by external corona. The partial discharge quantity showed about 3,800pC due to very high sinusoidal interferences at the measuring impedance terminal of the transformer bushing tap. In order to reject these noises, this paper applied RIV filter, band-pass filters and noise gating method. The resulting measuring sensitivity was improved from 3,800pC to 160pC.
권동진,구교선,우정욱,Kweon, Dong-Jin,Koo, Kyo-Sun,Woo, Jung-Wook 한국조명전기설비학회 2009 조명·전기설비학회논문지 Vol.23 No.8
최근 생활수준의 향상과 세계적인 녹색성장 정책으로 환경에 대한 관심이 고조되어, 전력분야에서도 환경친화적인 설비가 요구되어 지고 있다. 이에 따라 전력용 변압기도 소음저감에 대한 연구가 진행되어, 최근 55[dBA]급 154[kV] 저소음 변압기가 개발되었다. 저소음 변압기는 소음레벨은 저감되었지만, 중량 및 부피의 증가, 고무댐퍼의 적용 등이 변화가 있다. 이로 인하여 현장적용시 시험, 수송, 설치 및 운용 등에 대한 면밀한 검토가 필요한 실정이다. 따라서 본 논문에서는 효과적인 현장적용을 위해 소음레벨 기준치, 수송중량, 설치공간, 장기운용에 대한 사항을 검토하였다. Recently, there has been a growing global interest in environmental conservation, and the field of electric power equipment has been working to become more environment-friendly. Accordingly the 154[kV] low noise transformer is developed through the research. The low noise transformer decreases the audible noise level but the low noise transformer has several changes in the increase of weight and volume and the application of rubber damper. Therefore it is necessary to inspect the test, transportation, installation and operation about field application. In this paper, we investigate the standards of the audible noise level, the weight and volume of the transportation, the installation space and operation in order for effective field application.
권동진(Dong-Jin Kweon),최인혁(In-Hyuk Chio),정길조(Gil-Jo Jung) 한국조명·전기설비학회 2000 한국조명·전기설비학회 학술대회논문집 Vol.2000 No.-
This paper describes an application of the partial discharge measuring method in operating transformer. In the operating transformer, the useful PD signal may be superimposed by radio intereference voltage and impulse shaped noise signals generated by external corona or power electronics. In this paper, initial investigations after connecting the PD measuring system to the terminals of the measuring impedance showed a very high noise level of 3,700pC due to sinusoidal interferences. In order to reject these noises, this paper applied RIV and band-pass filters and noise gating method. The resulting measuring sensitivity was improved from 3,700pC to 160pC.
權東震(Dong-Jin Kweon),具敎善(Kyo-Sun Koo),金正贊(Jung-Chan Kim),金唯賢(Yoo-Hyun Kim) 대한전기학회 2008 전기학회논문지 Vol.57 No.10
According to the increase of power demand and expansion of downtown, it is necessary to install transformers additionally in operating substations and construct substations in residential area. But the public complaint has been increased due to the transformer noise of the substation. KEPCO has used a vibration preventing pad, various soundproof walls and an encloser to transformers in outdoor substations, and a soundproof door, shutter and wind-path soundproof equipment in indoor substations to block the sound propagation from the transformers. But these noise reduction methods are not satisfied. It should be considered to reduce transformer noise itself. In this paper, we investigated tank noise reduction techniques to develope a low noise transformer. According to the mode analysis of transformer tank, we found out characteristics and locations of noise on the tank, and it's nature vibration was also analysed. On the basis of these analysis, reinforcement equipment was installed around transformer tank, and ellipse shape tank was changed to round shape tank. The effect of noise reduction was evaluated using noise generation source.
權東震(Dong-Jin Kweon),具敎善(Kyo-Sun Koo),趙翼春(Ik-Choon Cho),金唯賢(Yoo-Hyun Kim),金隆植(Yung-Sig Kim) 대한전기학회 2008 전기학회논문지 Vol.57 No.11
According to the increase of power demand and expansion of downtown, it is necessary to install transformers additionally in operating substations and construct substations in residential area. But the public complaint is increased due to the transformer noise of the substation. KEPCO has used a vibration preventing pad, various soundproof walls and an encloser to transformers in outdoor substations, and a soundproof door, shutter and wind-path soundproof equipment in indoor substations to block the sound propagation of the transformers. But these noise reduction methods are not satisfied. It should be considered to reduce transformer noise itself In this paper, we investigated core noise reduction techniques to develope a low noise transformer. The techniques to reduce core noise of the transformer are application of high permeability grain oriented silicon sheets, decrease of magnetic flux density of core, application of 6step-lap core stacking method, improvement of core binding method(binding addition, band fixing) and application of rubber damper in oder to reduce transmission of core vibration, etc.
권동진(Dong-Jin Kweon),구교선(Kyo-Sun Koo),우정욱(Jung-Wook Woo) 한국조명·전기설비학회 2009 조명·전기설비학회논문지 Vol.23 No.8
최근 생활수준의 향상과 세계적인 녹색성장 정책으로 환경에 대한 관심이 고조되어, 전력분야에서도 환경친화적인 설비가 요구되어 지고 있다. 이에 따라 전력용 변압기도 소음저감에 대한 연구가 진행되어, 최근 55[㏈A]급 154[㎸] 저소음 변압기가 개발되었다. 저소음 변압기는 소음레벨은 저감되었지만, 중량 및 부피의 증가, 고무댐퍼의 적용 등의 변화가 있다. 이로 인하여 현장적용시 시험, 수송, 설치 및 운용 등에 대한 면밀한 검토가 필요한 실정이다. 따라서 본 논문에서는 효과적인 현장적용을 위해 소음레벨 기준치, 수송중량, 설치공간, 장기운용에 대한 사항을 검토하였다. Recently, there has been a growing global interest in environmental conservation, and the field of electric power equipment has been working to become more environment-friendly. Accordingly the 154[㎸] low noise transformer is developed through the research. The low noise transformer decreases the audible noise level but the low noise transformer has several changes in the increase of weight and volume and the application of rubber damper. Therefore it is necessary to inspect the test, transportation, installation and operation about field application. In this paper, we investigate the standards of the audible noise level, the weight and volume of the transportation, the installation space and operation in order for effective field application.