http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
보-단부 시험을 이용한 에폭시 도막 철근의 겹침 이음길이 평가
김지상,강원혁 한국건설순환자원학회 2020 한국건설순환자원학회 논문집 Vol.8 No.2
The application of epoxy coated reinforcements is increased as a means to prevent a corrosion of reinforcements embedded in reinforced concrete structures, However, epoxy coating may reduce the bond capacity between concrete and reinforcement, which results a longer development length and lap splice length. This paper aims to the possibility of modification in lap splice length from reduction of basic development length which was confirmed using a direct pull out test. Total 36 beam specimens were tested to compare the lap splice properties of normal and epoxy coated reinforcements with beam-end test for various lap lengths and diameters of reinforcements. According to the results on failure modes, deformations, and crack widths of this experiments, the modification factor of 1.2 should be used, though the direct bond capacity is assured through direct pull out test.
직접인발시험과 보-단부 시험을 이용한 에폭시 도막 철근의 부착특성
김지상,강원혁 한국건설순환자원학회 2019 한국건설순환자원학회 논문집 Vol.7 No.3
철근 콘크리트 구조물에서 철근의 부식은 내구성 문제를 발생시키고 있으며, 이에 대한 대책의 하나로 에폭시 도막철근이사용되고 있다. 그러나 에폭시 도막철근을 사용하는 경우 철근 부식에 대한 저항성능은 우수하나 철근에 에폭시 도막을 함으로써 콘크리트와의 부착력이 일반철근에 비하여 감소하는 단점이 있다. 따라서 부착성능에 대한 실험적인 확인이 필요하여ACI 408R에서 제시하는 대표적인 실험 방법인 휨 부재를 통하여 부착거동을 연구할 수 있는 보-단부 test와 직접인발을통해 부착 특성을 분석하는 Pullout test를 통하여 부착성능을 평가하였다. 에폭시 도막 철근의 부착실험은 휨 부재실험과직접인발 실험 모두 지름 13, 19mm의 철근에 대한 콘크리트 도막두께를 철근 지름의 3배로 하여 수행되었다. 실험 결과에폭시 도막철근의 부착강도는 철근의 지름이 증가할수록 에폭시 도막 철근과 일반철근의 부착강도차이가 증가하였고 파괴형상은 모두 뽑힘 파괴를 나타내었다. 또한, 직접인발시험으로 구한 부착-미끌림 관계에 근거하여 유한요소해석을 수행하고, 휨 실험결과와 비교하였다. 부착성능을 평가하는 방법으로 실제 구조물에 거동을 모사를 위해서 직접인발시험보다 휨 부재시험이 보다 유용한 것으로 사료된다.
외부 긴장재로 보강된 2경간 연속 강합성보의 초기 긴장력 결정
최동호 ( Choi Dong Ho ),강원혁 ( Kang Won Hyeok ),유동민 ( Yoo Dong Min ),전호탁 ( Jeon Ho Tak ) 한국구조물진단유지관리공학회 2005 한국구조물진단유지관리공학회 학술발표대회 논문집 Vol.9 No.2
This paper presents a method to enhance the load carrying capacity for a two span continuous composite beam strengthened with external tendons. The tendon is placed at the bottom of steel beam where the positive bending moment occurs, resulting in reducing the negative bending moment as well as the positive bending moment. This paper describes the procedure to determine the number of tendon and initial tendon force for the target rating factor. This method is applied to an existing composite beam, and it validity is confirmed.
외부 긴장재로 보강된 2경간 연속 강합성보의 초기 긴장력 결정
최동호(Choi Dong Ho),강원혁(Kang Won Hyeok),유동민(Yoo Dong Min),전호탁(Jeon Ho Tak) 한국구조물진단유지관리학회 2005 한국구조물진단학회 학술발표회논문집 Vol.9 No.2
This paper presents a method to enhance the load carrying capacity for a two span continuous composite beam strengthened with external tendons. The tendon is placed at the bottom of steel beam where the positive bending moment occurs, resulting in reducing the negative bending moment as well as the positive bending moment. This paper describes the procedure to determine the number of tendon and initial tendon force for the target rating factor. This method is applied to an existing composite beam, and it validity is confirmed.