http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
김규식(Gyu-Sik Kim) 대한전자공학회 2013 전자공학회논문지 Vol.50 No.6
지하철 역사의 미세먼지농도는 지하철 승객의 건강을 위해서 항상 모니터링되고 관리되어야 한다. 서울메트로와 서울도시철도공사는 몇몇 공기 오염물질을 주기적으로 측정하고 있다. 본 논문에서는 지하철 역사의 PM10 농도를 연속해서 측정하기 위해, 선형회귀분석법을 이용하여 저가의 광산란식 미세먼지측정기의 성능을 향상시키고자 하였다. 이와 더불어, 지하철 역사의 대합실, 승강장, 터널, 외기의 PM10, CO2. 습도, 온도 등을 측정하고 기록하기 위해 CDMA M2M 기법을 적용한 무선통신 모니터링 시스템을 구축하였다. The particle matter concentrations in the subway stations should be monitored and controlled for the health of commuters on the subway system. Seoul Metro and Seoul Metropolitan Rapid Transit Corporation are measuring several air pollutants regularly. In this paper, the reliability of the cheap instruments using light scattering method is improved with the help of a linear regression analysis technique to measure the PM10 concentrations continuously in the subway stations. In addition, a monitoring system is implemented to display and record the data of PM10, CO2, humidity, and temperature. To transmit and receive these measured sensor data, CDMA M2M wireless communication method is applied.
김규식(Gyu-Sik Kim),오준태(Joon-Tae Oh),김희식(Hie Sik Kim),김조천(Jo-Chun Kim) 대한전자공학회 2009 電子工學會論文誌-SC (System and control) Vol.46 No.2
본 연구에서는 비분산 적외선 방식을 이용한 일산화탄소, 이산화탄소 듀얼 센서 모듈을 실현한다. 비분산 적외선 방식은 가스분자가 특정 파장의 적외선을 흡수하는 특성을 이용하여 가스의 적외선 흡수도를 측정하여 농도로 환산하는 방식이다. 비분산 적외선 방식은 수명이 길고 정밀도가 높아 기존의 접촉식(화학식) 센서에 비해 우수한 특성을 가지고 있다. 중요한 기술은 NDIR의 핵심 부분인 광 공동의 설계 기술과 센서의 성능을 최종 결정짓는 농도-온도 교정 기술이다. 현재까지 개발된 광공동 기술은 CO2센서의 단일 센서 방식이었다. 본 연구에서는 이 기술을 접목한 일산화탄소까지 동시에 측정할 수 있는 광공동기술과 교정기술을 연구 개발하여 하나의 광 공동으로 이산화탄소와 일산화탄소를 동시에 측정 할 수 있는 고기능 센서를 실현하는 것이다. In this paper we discuss about the practical implementation of a combined CO and CO2 dual sensor module that is adapted by NDIR (Non-Dispersive Infrared) method that measures the absorbance of gas like CO and CO2 by using gas particles' characteristics that absorb specific wave lengths of infrared ray. NDIR has a long life time, excellent measurement and precision compared to the existing contact types or chemical types of CO2 sensors. Since optical cavity technology that had been developed until now can measure CO2 only we research and develop an optimal optical cavity design and density-temperature calibration technologies that can measure CO and CO2 at the same time and is important to decide the performance of the sensor module according to well-designed wave guides of the different length.
김규식(Gyu-Sik Kim),정해천(Hae-Chun Jung) 전력전자학회 1997 전력전자학술대회 논문집 Vol.1997 No.-
Along with the rapid growth in microelectronics and power electronics technologies, various advanced control methods have been successfully implemented in real time and shown to be useful in controlling CO₂arc welding systems with high dynamic performance. In this paper, the slope of welding currents is controlled not to be so high in the case of short circuit welding mode. This results in less spatter. In addition, the data-base is constructed for the optimal welding conditions.
金奎植(Gyu-Sik Kim) 대한전기학회 2007 전기학회논문지 Vol.56 No.3
A closed-loop sensorless stroke control system for a linear compressor has been designed. The motor parameters are identified as a function of the piston position and the motor current. They are stored in ROM table and used later for the accurate estimation of piston position. Also it was attempted to approximate the identified motor parameters to the Znd-order surface functions. The 2nd-order surface functions are divided into 2 or 4 sub-sections for more precise identification of motor parameters. Some experimental results are given in order to show the feasibility of the proposed control schemes for linear compressors.
김규식(Gyu-Sik Kim),나형욱(Hyeong-Uk Na),강상혁(Sang-Hyuk Kang) 대한전기학회 2008 대한전기학회 학술대회 논문집 Vol.2008 No.10
광학입자 계수기는 실내환경, 대기오염 및 클린룸 등 입자크기분포 측정장비로 가장 많이 사용된다. 광학입자 계수기에 샘플링된 입자는 관측체적 내로 1개씩 통과 하며 산란된 빛은 집광장치에 의해 광검출기로 전달한다. 이때 산란광의 양에 비례하여 전압(전류)의 세기로 변환하여 전기적 신호로서 나타나는 Pulse의 높이는 Calibration Data에 따라 입자의 크기로 변환하고 Pulse의 개수는 입자의 개수로 표시된다. 입자의 크기와 개수를 이용하여 부피로 환산 한 후 부유하는 입자의 평균 밀도를 이용하여 질량으로 환산시킨다. 이렇게 측정된 미세먼지 농도는 ZigBee통신을 사용하여 구축한 시스템을 통해서 중앙부에서 실시간으로 먼지 농도를 알 수 있다. 특히 멀티홉 기능을 이용하여 건물 구조가 복잡하거나 층간의 통신, 꺾인 부분이나 사무실 안과 밖과 같은 무선 통신이 원할 하지 못하는 경우를 극복하여 미세먼지의 농도 값을 측정 할 수도 있다.