RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Transmission Line Modeling and Algorithm Analysis Considering Parameter Asymmetry and Transient High-frequency Components

        Mo Shixun,Lv Zhipeng,Han Kunlun,Yuan Rongji,Yang Hao,Jiang Kunping,Liang Zhenshen 대한전기학회 2021 Journal of Electrical Engineering & Technology Vol.16 No.2

        When the power system is disturbed or the operation mode is changed, the electromagnetic transient process will occur, which will lead to the high frequency transient component and aff ect the protection and control of the power system. Therefore, attention should be paid to the analysis of high-frequency transient components when modeling and analyzing the system model. In view of the fact that the symmetrical-component theory is not suitable for asymmetric transmission lines and the phasor method is not suitable for transient analysis and calculation, this paper uses the phase coordinate approach and Laplace transform to derive the node voltage equation of three-phase π type transmission lines in frequency domain, which can be used to calculate the transient response of transmission lines caused by the change of operation mode or disturbance. And vectorized NILT is used to calculate the time domain solution, which greatly improves the calculation speed. The calculated results are basically consistent with those of ATP-EMTP, and can fully refl ect the transient characteristics. This method lays a foundation for analyzing the infl uence of high frequency transient components on power system and fault analysis considering transient process.

      • SCIESCOPUSKCI등재

        A Novel Three-Phase Four-Wire Grid-Connected Synchronverter that Mimics Synchronous Generators

        Tan, Qian,Lv, Zhipeng,Xu, Bei,Jiang, Wenqian,Ai, Xin,Zhong, Qingchang The Korean Institute of Power Electronics 2016 JOURNAL OF POWER ELECTRONICS Vol.16 No.6

        Voltage and frequency stability issues occur in existing centralized power system due to the high penetration of renewable energy sources, which decrease grid absorptive capacity of them. The grid-connected inverter that mimics synchronous generator characteristics with inertia characteristic is beneficial to electric power system stability. This paper proposed a novel three-phase four-wire grid-connected inverter with an independent neutral line module that mimics synchronous generators. A mathematical model of the synchronous generator and operation principles of the synchronverter are introduced. The main circuit and control parameters design procedures are also provided in detail. A 10 kW prototype is built and tested for further verification. The primary frequency modulation and primary voltage regulation characteristics of the synchronous generator are emulated and automatically adjusted by the proposed circuit, which helps to supports the grid.

      • KCI등재

        A Novel Three-Phase Four-Wire Grid-Connected Synchronverter that Mimics Synchronous Generators

        Qian Tan,Zhipeng Lv,Bei Xu,Wenqian Jiang,Xin Ai,Qingchang Zhong 전력전자학회 2016 JOURNAL OF POWER ELECTRONICS Vol.16 No.6

        Voltage and frequency stability issues occur in existing centralized power system due to the high penetration of renewable energy sources, which decrease grid absorptive capacity of them. The grid-connected inverter that mimics synchronous generator characteristics with inertia characteristic is beneficial to electric power system stability. This paper proposed a novel three-phase four-wire grid-connected inverter with an independent neutral line module that mimics synchronous generators. A mathematical model of the synchronous generator and operation principles of the synchronverter are introduced. The main circuit and control parameters design procedures are also provided in detail. A 10 ㎾ prototype is built and tested for further verification. The primary frequency modulation and primary voltage regulation characteristics of the synchronous generator are emulated and automatically adjusted by the proposed circuit, which helps to supports the grid.

      • KCI등재

        Dual-Loop Power Control for Single-Phase Grid-Connected Converters with LCL Filter

        Shuangjian Peng,An Luo,Yandong Chen,Zhipeng Lv 전력전자학회 2011 JOURNAL OF POWER ELECTRONICS Vol.11 No.4

        Grid-connected converters have widely adopted LCL filters to acquire high harmonic suppression. However, the LCL filter increases the system order so that the design of the system stability would be complicated. Recently, sole-loop control strategies have been used for grid-connected converters with L or LC filters. But if the sole-loop control is directly transplanted to gridconnected converters with LCL filters, the systems may be unstable. This paper presents a novel dual-loop power control strategy composed of a power outer loop and a current inner loop. The outer loop regulates the grid-connected power. The inner loop improves the system stability margin and suppresses the resonant peak caused by the LCL filter. To obtain the control variables, a single-phase current detection is proposed based on PQ theory. The system transfer function is derived in detail and the influence of control gains on the system stability is analyzed with the root locus. Simulation and experimental results demonstrate the feasibility of the proposed control.

      • SCIESCOPUSKCI등재

        Dual-Loop Power Control for Single-Phase Grid-Connected Converters with LCL Filter

        Peng, Shuangjian,Luo, An,Chen, Yandong,Lv, Zhipeng The Korean Institute of Power Electronics 2011 JOURNAL OF POWER ELECTRONICS Vol.11 No.4

        Grid-connected converters have widely adopted LCL filters to acquire high harmonic suppression. However, the LCL filter increases the system order so that the design of the system stability would be complicated. Recently, sole-loop control strategies have been used for grid-connected converters with L or LC filters. But if the sole-loop control is directly transplanted to grid-connected converters with LCL filters, the systems may be unstable. This paper presents a novel dual-loop power control strategy composed of a power outer loop and a current inner loop. The outer loop regulates the grid-connected power. The inner loop improves the system stability margin and suppresses the resonant peak caused by the LCL filter. To obtain the control variables, a single-phase current detection is proposed based on PQ theory. The system transfer function is derived in detail and the influence of control gains on the system stability is analyzed with the root locus. Simulation and experimental results demonstrate the feasibility of the proposed control.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼