http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Mu Danni,Fang Jiadan,Yu Songlin,Ma Yichen,Cheng Jin,Hu Yingying,Song Ailing,Zhao Fang,Zhang Qi,Qi Zhihong,Zhang Kui,Xia Liangyu,Qiu Ling,Zhu Huijuan,Cheng Xinqi 대한진단검사의학회 2024 Annals of Laboratory Medicine Vol.44 No.1
Background: Twenty-four-hour urinary free cortisol (UFC) measurement is the initial diagnostic test for Cushing’s syndrome (CS). We compared UFC determination by both direct and extraction immunoassays using Abbott Architect, Siemens Atellica Solution, and Beckman DxI800 with liquid chromatography-tandem mass spectrometry (LC-MS/MS). In addition, we evaluated the value of 24-hr UFC measured by six methods for diagnosing CS. Methods: Residual 24-hr urine samples of 94 CS and 246 non-CS patients were collected. A laboratory-developed LC-MS/MS method was used as reference. UFC was measured by direct assays (D) using Abbott, Siemens, and Beckman platforms and by extraction assays (E) using Siemens and Beckman platforms. Method was compared using Passing–Bablok regression and Bland–Altman plot analyses. Cut-off values for the six assays and corresponding sensitivities and specificities were calculated by ROC analysis. Results: Abbott-D, Beckman-E, Siemens-E, and Siemens-D showed strong correlations with LC-MS/MS (Spearman coefficient r=0.965, 0.922, 0.922, and 0.897, respectively), while Beckman-D showed weaker correlation (r=0.755). All immunoassays showed proportionally positive bias. The areas under the curve were 0.975 for Abbott-D, 0.972 for LC-MS/MS, 0.966 for Siemens-E, 0.948 for Siemens-D, 0.955 for Beckman-E, and 0.877 for Beckman-D. The cut-off values varied significantly (154.8–1,321.5 nmol/24 hrs). Assay sensitivity and specificity ranged from 76.1% to 93.2% and from 93.0% to 97.1%, respectively. Conclusions: Commercially available immunoassays for measuring UFC show different levels of analytical consistency compared to LC-MS/MS. Abbott-D, Siemens-E, and Beckman-E have high diagnostic accuracy for CS.
Research on Deep-Sea Pipeline Tube Bundle Heating System
Li Ding,Xinghua Ding,Weina Ren,Yingying Mu,Aiguo Lin 대한전기학회 2020 Journal of Electrical Engineering & Technology Vol.15 No.6
In order to ensure the safety of deep-sea submarine pipelines, this paper focuses on the analysis of the axial temperature distribution model of the submarine pipeline and the distribution parameter circuit model of the tube bundle heating system. Combined with these two models, theoretical analysis shows that the heating eff ect of the tube bundle heating system depends on the distributed circuit parameters and power frequency of the system. In order to improve the heat tracing effi ciency, the power frequency needs to be adjusted according to the change of the load temperature, so the power supply frequency of the tube bundle heating system based on the Hammerstein model is optimized. Using a neuro-fuzzy algorithm, not only the theoretical values of heating power and power frequency are obtained, but also the drawbacks of determining the above parameters based on engineering experiments are avoided. Moreover, the pipeline heating is effi cient and stable, the dynamic response is fast, and the working condition is also well adapted.