http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Dubey Santosh K.,Tokashiki Tsutomu,Suzuki Satoru The Microbiological Society of Korea 2006 The journal of microbiology Vol.44 No.2
The tributyltin (TBT)-resistant bacterium, Pseudomonas aeruginosa 25W, which was isolated in seawater from the Arabian Sea, was subjected to transcriptome analysis in the presence of high concentrations of TBT. Only slight effects were observed at TBT concentration of $50{\mu}M$, but exposure to $500{\mu}M$ resulted in the upregulation of 6 genes and the downregulation of 75. Among the 75 downregulated genes, 53% (40 out of 75) were of hypothetical function, followed by 14 transcriptional regulation- and translation-associated genes. The results of this study indicated that although the 25W strain was highly resistant to TBT, high concentrations of TBT result in toxic effect on the transcriptional and translational levels. The target genes likely belong to a specific category of transcription- and translation-associated genes rather than to other gene categories.
Santosh K. Dubey,Tsutomu Tokashiki,Satoru Suzuk 한국미생물학회 2006 The journal of microbiology Vol.44 No.2
The tributyltin (TBT)-resistant bacterium, Pseudomonas aeruginosa 25W, which was isolated in seawater from the Arabian Sea, was subjected to transcriptome analysis in the presence of high concentrations of TBT. Only slight effects were observed at TBT concentration of 50 μM, but exposure to 500 μM resulted in the upregulation of 6 genes and the downregulation of 75. Among the 75 downregulated genes, 53% (40 out of 75) were of hypothetical function, followed by 14 transcriptional regulation- and translationassociated genes. The results of this study indicated that although the 25W strain was highly resistant to TBT, high concentrations of TBT result in toxic effect on the transcriptional and translational levels. The target genes likely belong to a specific category of transcription- and translation-associated genes rather than to other gene categories.
Kazuta Yamashita,Hisanori Ikuma,Takuya Tokashiki,Takashi Maehara,Akihiro Nagamachi,Yoichiro Takata,Toshinori Sakai,Kosaku Higashino,Koichi Sairyo 대한척추외과학회 2017 Asian Spine Journal Vol.11 No.1
Study Design: Prospective study. Purpose: During fluoroscopically guided spinal procedure, the hands of spinal surgeons are placed close to the field of radiation and may be exposed to ionizing radiation. This study directly measured the radiation exposure to the hand of a spinal interventionalist during fluoroscopically guided procedures. Overview of Literature: Fluoroscopically guided spinal procedures have been reported to be a cause for concern due to the radiation exposure to which their operators are exposed. Methods: This prospective study evaluated the radiation exposure of the hand of one spinal interventionalist during 52 consecutive fluoroscopic spinal procedures over a 3-month period. The interventionalist wore three real-time dosimeters secured to the right forearm, under the lead apron over the chest, and outside the lead apron over the chest. Additionally, one radiophotoluminescence glass dosimeter was placed under the lead apron over the left chest and one ring radiophotoluminescence glass dosimeter was worn on the right thumb. The duration of exposure and radiation dose were measured for each procedure. Results: The average radiation exposure dose per procedure was 14.9 μSv, 125.6 μSv, and 200.1 μSv, inside the lead apron over the chest, outside the lead apron over the chest, and on the right forearm, respectively. Over the 3-month period, the protected radiophotoluminescence glass dosimeter over the left chest recorded less than the minimum reportable dose, whereas the radiophotoluminescence glass ring dosimeter recorded 368 mSv for the thumb. Conclusions: Our findings indicated that the cumulative radiation dose measured at the dominant hand may exceed the annual dose limit specified by the International Commission on Radiological Protection. Spinal interventionalists should take special care to limit the duration of fluoroscopy and radiation exposure.