        Radiation Exposure to the Hand of a Spinal Interventionalist during Fluoroscopically Guided Procedures

        Kazuta Yamashita,Hisanori Ikuma,Takuya Tokashiki,Takashi Maehara,Akihiro Nagamachi,Yoichiro Takata,Toshinori Sakai,Kosaku Higashino,Koichi Sairyo 대한척추외과학회 2017 Asian Spine Journal Vol.11 No.1

        Study Design: Prospective study. Purpose: During fluoroscopically guided spinal procedure, the hands of spinal surgeons are placed close to the field of radiation and may be exposed to ionizing radiation. This study directly measured the radiation exposure to the hand of a spinal interventionalist during fluoroscopically guided procedures. Overview of Literature: Fluoroscopically guided spinal procedures have been reported to be a cause for concern due to the radiation exposure to which their operators are exposed. Methods: This prospective study evaluated the radiation exposure of the hand of one spinal interventionalist during 52 consecutive fluoroscopic spinal procedures over a 3-month period. The interventionalist wore three real-time dosimeters secured to the right forearm, under the lead apron over the chest, and outside the lead apron over the chest. Additionally, one radiophotoluminescence glass dosimeter was placed under the lead apron over the left chest and one ring radiophotoluminescence glass dosimeter was worn on the right thumb. The duration of exposure and radiation dose were measured for each procedure. Results: The average radiation exposure dose per procedure was 14.9 μSv, 125.6 μSv, and 200.1 μSv, inside the lead apron over the chest, outside the lead apron over the chest, and on the right forearm, respectively. Over the 3-month period, the protected radiophotoluminescence glass dosimeter over the left chest recorded less than the minimum reportable dose, whereas the radiophotoluminescence glass ring dosimeter recorded 368 mSv for the thumb. Conclusions: Our findings indicated that the cumulative radiation dose measured at the dominant hand may exceed the annual dose limit specified by the International Commission on Radiological Protection. Spinal interventionalists should take special care to limit the duration of fluoroscopy and radiation exposure.

      • Treatment of Thoracolumbar Spinal Fracture Accompanied by Diffuse Idiopathic Skeletal Hyperostosis Using Transdiscal Screws for Diffuse Idiopathic Skeletal Hyperostosis: Preliminary Results

        Mehta Gaurav,Hisanori Ikuma,Shinichiro Takao,Yoichi Inoue,Tomohiko Hirose,Keitaro Matsukawa,Keisuke Kawasaki 대한척추외과학회 2021 Asian Spine Journal Vol.15 No.3

        Study Design: This retrospective case series enrolled 13 patients who underwent posterior fixation with both transdiscal screws for diffuse idiopathic skeletal hyperostosis (TSDs) and pedicle screws (PSs) to treat spinal injury accompanied by diffuse idiopathic skeletal hyperostosis (DISH). Purpose: To describe the usefulness, feasibility, and biomechanics of TSD. Overview of Literature: Vertebral bodies accompanied by DISH generally have lower bone mineral density than normal vertebral bodies because of the stress shielding effect. This phenomenon tends to makes screw fixation challenging. To our knowledge, solutions for this issue have not previously been reported. Methods: Patients were assessed using the data on surgical time, estimated intraoperative blood loss, mean number of stabilized intervertebral segments, number of screws used, perioperative complications, union rate, and the three-level EuroQol five-dimensional questionnaire (EQ5D-3L) score at the final follow-up. The Hounsfield unit (HU) values of the screw trajectory area, and the actual intraoperative screw insertion torque of TSDs and PSs were also analyzed and compared. Results: The surgical time and estimated intraoperative blood loss were 165.9±45.5 minutes and 71.0±53.4 mL, respectively. The mean number of stabilized intervertebral segments was 4.6±1.0. The number of screws used was 4.9±1.3 for TSDs and 3.0±1.4 for PSs. One death occurred after surgery. The union rate and EQ5D-3L scores were 100% and 0.608±0.128, respectively. The HU value and actual intraoperative screw insertion torque of TSDs were significantly better than those of PSs (p<0.001, p=0.033). Conclusions: We were able to achieve stable surgical outcomes using the combination of TSDs and PSs. The HU value and actual intraoperative screw insertion torque were significantly higher for TSDs than for PSs. Based on these results, when treating thoracolumbar spinal fractures accompanied by DISH in elderly populations, the TSD could be a stronger anchor than the PS.