Purpose: We investigated the predictive factors for acute urinary retention (AUR) after transperineal template-guided mapping biopsy (TTMB). Materials and Methods: We retrospectively reviewed the records of 459 patients who had undergone TTMB between May 2017 and July 2020. Overall complications after TTMB were analyzed and categorized according to the Clavien-Dindo classification. Factors that were likely to affect AUR were analyzed using a logistic regression model. Results: Overall complications after TTMB were observed in 95 of the 459 patients (20.7%), of which AUR was the most commonly reported (17.4%, n=80), followed by hematuria (3.1%, n=14). Hematuria in one patient was categorized as Clavien-Dindo grade IIIa. All remaining complications were Clavien-Dindo grade I. In the multivariate regression model, age ≥65 (odds ratio, 2.44; 95% confidence interval [CI], 1.42–4.17; p=0.001), prostate volume ≥30 mL (odds ratio, 3.72; 95% CI, 1.19–11.62; p<0.02), and number of biopsy cores ≥30 (odds ratio, 2.89; 95% CI, 1.29–6.43; p=0.01) were identified as the predictors for AUR after TTMB. Conclusions: AUR is the most common complication after TTMB. Age ≥65 years, prostate volume ≥30 mL, and number of biopsy cores ≥30 were significant predictors of AUR following TTMB.
경년변화에 따른 내화도료의 내화성능에 관한 실험적 연구
김대회(Kim, Dae-Hoi),성시창(Sung, Si-Chang),최동호(Choi, Dong-Ho),박수영(Park, Soo-Young),이세현(Lee, Sea-Hyun),이종찬(Lee, Jong-Chan) 한국화재소방학회 2008 한국화재소방학회 학술대회 논문집 Vol.2008 No.춘계
Applying fire resistive coating to steel members is one of the general methods to secure fire resistance performance of steel members. And intumescent coating system is currently one of methods giving fire resistance to steel members. Intumescent coating system for fire resistance, however, has undesirable weaknesses that fire resistance performance of steel members is being deteriorated due to cracks and falling-offs of the coverings as time goes after completion of the coverings to the members. This study is designed to understand changes in fire resistance performance of intumescent coating system through follow-up tests on temperature of unexposed surface for the domestic intumescent coating system.
환경시험방법에 의한 내화도료의 내화성능에 관한 실험적 연구
박수영(Park, Soo-Young),성시창(Sung, Si-Chang),최동호(Choi, Dong-Ho),김대회(Kim, Dae-Hoi),이세현(Lee, Sea-Hyun),이종찬(Lee, Jong-Chan) 한국화재소방학회 2008 한국화재소방학회 학술대회 논문집 Vol.2008 No.춘계
This study is designed to understand changes in fire resistance performance of intumescent coating system through follow-up tests on temperature of unexposed surface for the domestic intumescent coating system by environmental testing procedure.
최동호(Choi, Dong-Ho),성시창(Sung, Si-Chang),김대회(Kim, Dae-Hoi),박수영(Park, Soo-Young),이세현(Lee, Sea-Hyun),이종찬(Lee, Jong-Chan) 한국화재소방학회 2008 한국화재소방학회 학술대회 논문집 Vol.2008 No.춘계
Intumescent coating system for fire resistance has undesirable weaknesses that fire resistance performance of steel members is being deteriorated due to cracks and falling-offs of the coverings as time goes after completion of the coverings to the members. This study is designed to understand changes in durability of intumescent coating system through follow-up tests on bond strength and thickness for the domestic intumescent coating system.
공진회피를 위한 전조등조립체의 고유진동수 해석 및 신뢰성 개선 연구
남윤욱 ( Nam Yoonwook ),윤효진 ( Yoon Hyojin ),강동현 ( Kang Dong-hyun ),성시일 ( Sung Si-il ) 한국품질경영학회 2018 품질경영학회지 Vol.46 No.3
Purpose: This article provides a cause of breakage and a method for improving reliability of the headlight system installed in the main battle tank K2. Method: The natural frequency of the headlight system is estimated by using the finite element method. In addition, the allowable stress level under the severe conditions is provided through vibration test of a single item and a system level. Results: Based on the finite element analysis and the vibration test in the frequency domain, the lamp of the left headlight system fails by the resonance effect. Conclusion: For improving the reliability of the headlight system, the thickness of protector frame is increased to avoid the resonance effect.
경년변화에 따른 내화도료의 내구성 및 내화성능 변화에 관한 실험적 연구
최동호(Choi Dong-Ho),서희원(Seo Hee-Won),김대회(Kim Dae-Hoi),성시창(Sung Si-Chang),이세현(Lee Sea-Hyun),이종찬(Lee Jong-Chan) 대한건축학회 2007 大韓建築學會論文集 : 構造系 Vol.23 No.11
Applying fire resistive coating to steel members is one of the general methods to secure fire resistance performance of steel members. And intumescent coating system is currently one of methods giving fire resistance to steel members. Intumescent coating system for fire resistance, however, has undesirable weaknesses that fire resistance performance of steel members is being deteriorated due to cracks and falling-offs of the coverings as time goes after completion of the coverings to the members. So it is necessary to understand changes of the fire resistance performance and durability of the intumescent coating system over a time elapse and to reflect such change properly into the building design and construction. This study is designed to understand changes in durability of intumescent coating system through follow-up tests on temperature of unexposed surface and bond strength for the domestic intumescent coating system.