http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
윤동원(D. W. Yun),윤소남(S. N. Yun),이성휘(S. H. Lee),신행봉(H. B. Shin) 한국동력기계공학회 2009 한국동력기계공학회 학술대회 논문집 Vol.2009 No.11
In this research, a proportional solenoid has been studied. To do this, A FE analysis is used and some analysis cases are made by varying the control cone angle, applied current, and plunger stroke. From the analysis, it is found that the performance of the proportional solenoid valve depends on the angle of the control cone and the proper angle of the control cone can be found through the analysis.