RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Fluid Attenuated Inversion Recovery (FLAIR) Imaging of the Normal Brain: Comparisons between Under the Conditions of 3.0 Tesla and 1.5 Tesla

        손철호,Robert J. Sevick,Richard Frayne,장혁원,김상표,김대광 대한영상의학회 2010 Korean Journal of Radiology Vol.11 No.1

        Objective: The aim of this study was to evaluate the differences in normal brain MRI findings between under 3.0 Tesla (T) and 1.5T MRI conditions with the use of the fluid attenuated inversion recovery (FLAIR) sequences. Materials and Methods: Eleven normal adults underwent imaging with the use of the FLAIR sequences on both 1.5T and 3.0T scanners. Two neuroradiologists compared the signal intensity (SI) of the centrum semiovale (CS), pulvinar thalami (PT) and normal iron deposit structures (IDSs) on the 3.0T and 1.5T FLAIR images, and they evaluated three MRI findings qualitatively: high SI of CS; low SI of PT; low SI of IDS. We also evaluated signal-to-noise ratios (SNRs) for the CS, PT, red nucleus and cerebellar dentate nucleus on the FLAIR images. Results: Based on qualitative analyses, the 3.0T FLAIR images showed all three MRI findings for all cases. Low SI for the PT in seven cases (64%), high SI of the CS in one case (9%) and low SI of the cerebellar dentate nucleus in one case (9%) were visualized only on 3.0T FLAIR images. The mean SNRs of the PT, red nucleus and dentate nucleus in patients where 3.0T FLAIR imaging was performed were significantly lower as compared with the SNRs on 1.5T FLAIR images. The SNR of the CS was not significantly different between under the two magnetic field strengths (p > 0.05). Conclusion: We have demonstrated that normal, high and low SIs of the CS, PT and IDS on 3.0T FLAIR images were depicted more frequently and more prominently as compared with those on 1.5T FLAIR images in normal adult brains. Objective: The aim of this study was to evaluate the differences in normal brain MRI findings between under 3.0 Tesla (T) and 1.5T MRI conditions with the use of the fluid attenuated inversion recovery (FLAIR) sequences. Materials and Methods: Eleven normal adults underwent imaging with the use of the FLAIR sequences on both 1.5T and 3.0T scanners. Two neuroradiologists compared the signal intensity (SI) of the centrum semiovale (CS), pulvinar thalami (PT) and normal iron deposit structures (IDSs) on the 3.0T and 1.5T FLAIR images, and they evaluated three MRI findings qualitatively: high SI of CS; low SI of PT; low SI of IDS. We also evaluated signal-to-noise ratios (SNRs) for the CS, PT, red nucleus and cerebellar dentate nucleus on the FLAIR images. Results: Based on qualitative analyses, the 3.0T FLAIR images showed all three MRI findings for all cases. Low SI for the PT in seven cases (64%), high SI of the CS in one case (9%) and low SI of the cerebellar dentate nucleus in one case (9%) were visualized only on 3.0T FLAIR images. The mean SNRs of the PT, red nucleus and dentate nucleus in patients where 3.0T FLAIR imaging was performed were significantly lower as compared with the SNRs on 1.5T FLAIR images. The SNR of the CS was not significantly different between under the two magnetic field strengths (p > 0.05). Conclusion: We have demonstrated that normal, high and low SIs of the CS, PT and IDS on 3.0T FLAIR images were depicted more frequently and more prominently as compared with those on 1.5T FLAIR images in normal adult brains.

      • KCI등재

        Automatic Surface Matching for the Registration of LIDAR Data and MR Imagery

        Ayman Fawzy Habib,Rita Wai Ting Cheng,Eui-Myoung Kim,Edson Aparecido Mitishita,Richard Frayne,Janet Lenore Ronsky 한국전자통신연구원 2006 ETRI Journal Vol.28 No.2

        Several photogrammetric and geographic information system applications such as surface matching, object recognition, city modeling, environmental monitoring, and change detection deal with multiple versions of the same surface that have been derived from different sources and/or at different times. Surface registration is a necessary procedure prior to the manipulation of these 3D datasets. This need is also applicable in the field of medical imaging, where imaging modalities such as magnetic resonance imaging (MRI) can provide temporal 3D imagery for monitoring disease progression. This paper will present a general automated surface registration procedure that can establish correspondences between conjugate surface elements. Experimental results using light detection and ranging (LIDAR) and MRI data will verify the feasibility, robustness, and accuracy of this approach.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼