http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Ding, Kun,Wang, Xiang,Zhai, Quan-Xin,Xu, Jun-Wei,Zhang, Jing-Wei,Liu, Hai-Hao The Korean Institute of Power Electronics 2014 JOURNAL OF POWER ELECTRONICS Vol.14 No.4
The power-voltage (P-V) curve of photovoltaic (PV) arrays connected in parallel to bypass diodes would have several local maximum power points (LMPP) under partial shading conditions (PSC). Conventional maximum power point tracking (MPPT) methods fail to search for the global maximum power point (MPP) because the searched peak point may remain at the LMPP on the P-V curve under PSC. This study proposes an improved MPPT algorithm to ensure that PV arrays operate at global maximum power point (GMPP) under PSC. The proposed algorithm is based on a critical study and a series of observations of PV characteristics under PSC. Results show the regularity of voltage interval between LMPPs. The algorithm has the advantages of rapidly reaching GMPP, maintaining stability, and recovering GMPP quickly when the operating condition changes. Simulation and experimental results demonstrate the feasibility of the proposed algorithm.
Prevalence and Risk Factors of Cerebral Small Vessel Disease in a Chinese Population-Based Sample
Fei Han,Fei-Fei Zhai,Quan Wang,Li-Xin Zhou,Jun Ni,Ming Yao,Ming-Li Li,Shu-Yang Zhang,Li-Ying Cui,Zheng-Yu Jin,Yi-Cheng Zhu 대한뇌졸중학회 2018 Journal of stroke Vol.20 No.2
Background and Purpose Epidemiological data of cerebral small vessel disease (CSVD) in the general population of China are lacking. We report on the prevalence of lacunes, white matter hyperintensity (WMH), and cerebral microbleeds (CMBs) in a community-based sample in China and compare the results with those of other studies. Methods This was a cross-sectional analysis of the population-based Shunyi Study in China. A total of 1,211 stroke-free participants (mean age, 55.6±9.3 years; 37.4% men) with available 3 Tesla (3T) magnetic resonance images were included in this analysis. Demographic information and risk factor data were assessed. The overall and age-specific prevalence of lacunes, WMH, and CMBs was evaluated. Associations between cardiovascular risk factors and the presence of these lesions were analyzed by multiple logistic regression. Results Our study showed a prevalence of 14.5% for lacunes, 72.1% for periventricular hyperintensity (PVH), 65.4% for deep white matter hyperintensity (DWMH), and 10.6% for CMBs. When compared with other community-based samples, individuals in the same age group showed a higher burden of lacunes and a relatively lower prevalence of CMBs. Advanced age was independently associated with the prevalence of these CSVD markers, while the presence of hypertension increased the risk of lacunes, PVH/DWMH, and CMBs in deep or infratentorial locations. Conclusions A higher burden of lacunes but a relatively lower prevalence of CMBs was observed in this Chinese population. This notable result highlights the challenge of CSVD prevention in China. Chinese have a risk factor profile for CSVD similar to those in other populations.
Kun Ding,Xiang Wang,Quan-Xin Zhai,Jun-Wei Xu,Jing-Wei Zhang,Hai-Hao Liu 전력전자학회 2014 JOURNAL OF POWER ELECTRONICS Vol.14 No.4
The power?voltage (P?V) curve of photovoltaic (PV) arrays connected in parallel to bypass diodes would have several local maximum power points (LMPP) under partial shading conditions (PSC). Conventional maximum power point tracking (MPPT) methods fail to search for the global maximum power point (MPP) because the searched peak point may remain at the LMPP on the P?V curve under PSC. This study proposes an improved MPPT algorithm to ensure that PV arrays operate at global maximum power point (GMPP) under PSC. The proposed algorithm is based on a critical study and a series of observations of PV characteristics under PSC. Results show the regularity of voltage interval between LMPPs. The algorithm has the advantages of rapidly reaching GMPP, maintaining stability, and recovering GMPP quickly when the operating condition changes. Simulation and experimental results demonstrate the feasibility of the proposed algorithm.
Jun Wei Wu,Yu Rong Xing,Yi Bo Wen,Tian Fang Li,Quan De Feng,Xiao Ping Shang,Yun Long Li,Jin Jin Feng,Xin Xin Wang,Rong Qun Zhai,Xiang Fei He,Tao Chen,Xin Jian Liu,Jian Guo Wen 대한배뇨장애요실금학회 2016 International Neurourology Journal Vol.20 No.2
Purpose: To investigate the prevalence of spina bifida occulta (SBO) and its relationship with the presence of overactive bladder (OAB) in middle-aged and elderly people in China. Methods: A cross-sectional community-based survey was carried out at 7 communities in Zhengzhou City, China from December 15, 2013 to June 10, 2014, where residents aged over 40 years were randomly selected to participate. All of the participants underwent lumbosacral radiographic analysis and relevant laboratory tests. A questionnaire including basic information, past medical history and present illness, and the OAB symptom score was filled out by all participants. Chi-square tests and logistic regression were used for data analysis with a P-value of <0.05 denoting statistical significance. Results: A total of 1,061 subjects were qualified for the final statistical analysis (58.8±11.7 years; male, 471 [44.4%]; female, 590 [55.6%]). The overall prevalence of SBO was 15.1% (160 of 1,061): 18.3% (86 of 471) in men and 12.5% (74 of 590) in women. Among these subjects, 13.7% (145 of 1,061) had OAB: 13.2% (62 of 471) in men and 14.1% (83 of 590) in women. The results of logistic regression showed that age, SBO, history of cerebral infarction (HCI), and constipation were risk factors for OAB (P<0.05), while sex, history of childhood enuresis (HCE), body mass index (BMI), and diabetes mellitus (DM) were not (P>0.05). In men, age, SBO, and constipation were risk factors for OAB (P<0.05), while HCE, BMI, DM, HCI, and benign prostate hyperplasia were not (P>0.05). In women, age, SBO, and HCI were risk factors for OAB (P<0.05), while HCE, BMI, DM, vaginal delivery, and constipation were not (P>0.05). Conclusions: The prevalence of SBO is high and it is related to OAB in middle-aged and elderly people in China.
The Influence of Changing PV Array Interconnections under a Non-uniform Irradiance
Kun Ding,Li Feng,Si-Yu Qin,Jing Mao,Jing-Wei Zhang,Xiang Wang,Tao Peng,Quan-Xin Zhai 전력전자학회 2016 JOURNAL OF POWER ELECTRONICS Vol.16 No.2
Usually, the output characteristics of a photovoltaic (PV) array are significantly affected by non-uniform irradiance which is caused by ambient obstacles, clouds, orientations, tilts, etc. Some local maximum power points (LMPP) in the current-voltage (I-V) curves of a PV array can result in power losses of the array. However, the output power at the global maximum power point (GMPP) is different in different interconnection schemes in a PV array. Therefore, based on the theoretical analysis and mathematical derivation of different topological structures of a PV array, this paper investigated the output characteristics of dual series PV arrays with different interconnections. The proposed mathematical models were also validated by experimental results. Finally, this paper also concluded that in terms of performance, the total cross tied (TCT) interconnection was not always the optimal structure, especially in a dual series PV array. When one of the PV modules was severely mismatched, the TCT worked worse than the series parallel (SP) structure. This research can provide guidance for switching the interconnection to gain the greatest energy yield in a changeable- structure PV system.
The Influence of Changing PV Array Interconnections under a Non-uniform Irradiance
Ding, Kun,Feng, Li,Qin, Si-Yu,Mao, Jing,Zhang, Jing-Wei,Wang, Xiang,Peng, Tao,Zhai, Quan-Xin The Korean Institute of Power Electronics 2016 JOURNAL OF POWER ELECTRONICS Vol.16 No.2
Usually, the output characteristics of a photovoltaic (PV) array are significantly affected by non-uniform irradiance which is caused by ambient obstacles, clouds, orientations, tilts, etc. Some local maximum power points (LMPP) in the current-voltage (I-V) curves of a PV array can result in power losses of the array. However, the output power at the global maximum power point (GMPP) is different in different interconnection schemes in a PV array. Therefore, based on the theoretical analysis and mathematical derivation of different topological structures of a PV array, this paper investigated the output characteristics of dual series PV arrays with different interconnections. The proposed mathematical models were also validated by experimental results. Finally, this paper also concluded that in terms of performance, the total cross tied (TCT) interconnection was not always the optimal structure, especially in a dual series PV array. When one of the PV modules was severely mismatched, the TCT worked worse than the series parallel (SP) structure. This research can provide guidance for switching the interconnection to gain the greatest energy yield in a changeable- structure PV system.