RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • THE STANDARDISATION-LOCALISATION DILEMMA OF BRAND COMMUNICATIONS FOR LUXURY FASHION RETAILERS’ INTERNATIONALISATION INTO CHINA

        Sindy Liu,Patsy Perry,Christopher Moore 글로벌지식마케팅경영학회 2014 Global Marketing Conference Vol.2014 No.6

        This paper considers the standardisation-localisation debate and analyses qualitative data from 22 luxury fashion retailers to reveal the decision-making process for marketing strategies that support entry into China, in terms of balancing the ‘global-local dilemma’ in an emerging marketplace alongside the need to maintain exclusivity of brand image across markets.

      • THE STANDARDISATION-LOCALISATION DILEMMA OF BRAND COMMUNICATIONS FOR LUXURY FASHION RETAILERS’ INTERNATIONALISATION INTO CHINA

        Sindy Liu,Patsy Perry,Christopher Moore 글로벌지식마케팅경영학회 2014 Global Marketing Conference Vol.2014 No.7

        This paper considers the standardisation-localisation debate and analyses qualitative data from 22 luxury fashion retailers to reveal the decision-making process for marketing strategies that support entry into China, in terms of balancing the ‘global-local dilemma’ in an emerging marketplace alongside the need to maintain exclusivity of brand image across markets.

      • KCI등재

        Laboratory model to evaluate efficacy of an experimental titanium oxide nanofibers bleaching agent

        Tran Clayton,Choi Ellin,Watu Brittany,Oyoyo Udochukwu,Perry Christopher,Kwon So Ran 대한치과보존학회 2021 Restorative Dentistry & Endodontics Vol.46 No.4

        Objectives This study aimed to use a laboratory model to evaluate the efficacy of an experimental bleaching agent. Materials and Methods The model used human extracted molars that were treated and measured for bleaching efficacy. Teeth (n = 50) were distributed into 5 groups: Negative control (NC): immersion in water for 8 hours; Nanofibers (NFs): Experimental titanium dioxide nanofibers with stirring and light activation for 8 hours; Whitestrips (WS): Crest 3D White Glamorous White Whitestrips, 2 applications daily for 30 minutes, 14 days; 1% hydrogen peroxide (HP) standard: 1% hydrogen peroxide for 8 hours; and 30% HP standard: 30% hydrogen peroxide for 8 hours. Instrumental measurements were performed using a spectrophotometer. Results were recorded at baseline, 1-day post-bleaching, and 1-week post-bleaching. Kruskal-Wallis procedure was used to determine differences in color change. Pearson correlation was used to evaluate the relationship between visual and instrumental measurements. Tests of hypotheses were 2-sided with alpha = 0.05. Results There was no significant difference in color parameters (L1, a1, b1, and shade guide units [SGU]) at baseline (p > 0.05). There was a significant difference among the groups for overall color change (ΔE*ab) and change in shade guide units (ΔSGU) at 1-day and 1-week post-bleaching (p < 0.05). The higher the HP concentration, the higher the color change as expressed in ΔSGU and ΔE*ab. The negative control exceeded the perceptibility threshold of ΔE* = 1.2 regardless of time point. NFs showed a decrease in chroma, but were not statistically different compared to the negative control. Conclusions The laboratory model was successful in screening an experimental bleaching agent. Objectives This study aimed to use a laboratory model to evaluate the efficacy of an experimental bleaching agent. Materials and Methods The model used human extracted molars that were treated and measured for bleaching efficacy. Teeth (n = 50) were distributed into 5 groups: Negative control (NC): immersion in water for 8 hours; Nanofibers (NFs): Experimental titanium dioxide nanofibers with stirring and light activation for 8 hours; Whitestrips (WS): Crest 3D White Glamorous White Whitestrips, 2 applications daily for 30 minutes, 14 days; 1% hydrogen peroxide (HP) standard: 1% hydrogen peroxide for 8 hours; and 30% HP standard: 30% hydrogen peroxide for 8 hours. Instrumental measurements were performed using a spectrophotometer. Results were recorded at baseline, 1-day post-bleaching, and 1-week post-bleaching. Kruskal-Wallis procedure was used to determine differences in color change. Pearson correlation was used to evaluate the relationship between visual and instrumental measurements. Tests of hypotheses were 2-sided with alpha = 0.05. Results There was no significant difference in color parameters (L1, a1, b1, and shade guide units [SGU]) at baseline (p > 0.05). There was a significant difference among the groups for overall color change (ΔE*ab) and change in shade guide units (ΔSGU) at 1-day and 1-week post-bleaching (p < 0.05). The higher the HP concentration, the higher the color change as expressed in ΔSGU and ΔE*ab. The negative control exceeded the perceptibility threshold of ΔE* = 1.2 regardless of time point. NFs showed a decrease in chroma, but were not statistically different compared to the negative control. Conclusions The laboratory model was successful in screening an experimental bleaching agent.

      • KCI등재

        Significance of Facet Fluid Index in Anterior Cervical Degenerative Spondylolisthesis

        Lee Yunsoo,Heard Jeremy C.,Lambrechts Mark J.,Kern Nathaniel,Wiafe Bright,Goodman Perry,Mangan John J.,Canseco Jose A.,Kurd Mark F.,Kaye Ian D.,Hilibrand Alan S.,Vaccaro Alexander R.,Kepler Christophe 대한척추외과학회 2024 Asian Spine Journal Vol.18 No.1

        Study Design: Retrospective cohort study.Purpose: To correlate cervical facet fluid characteristics to radiographic spondylolisthesis, determine if facet fluid is associated with instability in cervical degenerative spondylolisthesis, and examine whether vertebral levels with certain facet fluid characteristics and spondylolisthesis are more likely to be operated on.Overview of Literature: The relationship between facet fluid and lumbar spondylolisthesis is well-documented; however, there is a paucity of literature investigating facet fluid in degenerative cervical spondylolisthesis.Methods: Patients diagnosed with cervical degenerative spondylolisthesis were identified from a hospital’s medical records. Demographic and surgical characteristics were collected through a structured query language search and manual chart review. Radiographic measurements were made on preoperative MRIs for all vertebral levels diagnosed with spondylolisthesis and adjacent undiagnosed levels between C3 and C6. The facet fluid index was calculated by dividing the facet fluid measurement by the width of the facet. Bivariate analysis was conducted to compare facet characteristics based on radiographic spondylolisthesis and spondylolisthesis stability.Results: We included 154 patients, for whom 149 levels were classified as having spondylolisthesis and 206 levels did not. The average facet fluid index was significantly higher in patients with spondylolisthesis (0.26±0.07 vs. 0.23±0.08, p <0.001). In addition, both fluid width and facet width were significantly larger in patients with spondylolisthesis (p <0.001 each). Cervical levels in the fusion construct demonstrated a greater facet fluid index and were more likely to have unstable spondylolisthesis than stable spondylolisthesis (p <0.001 each).Conclusions: Facet fluid index is associated with cervical spondylolisthesis and an increased facet size and fluid width are associated with unstable spondylolisthesis. While cervical spondylolisthesis continues to be an inconclusive finding, vertebral levels with spondylolisthesis, especially the unstable ones, were more likely to be included in the fusion procedure than those without spondylolisthesis.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼