http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
김민기,최영수,김기현,배자성,이동호,성기영,김정수,박우찬,Min-Ki Kim,M,D,Young-Soo Choi,M,D,Ki-Hyun Kim,M,D,Ja-Sung Bae,M,D,Dong-Ho Lee,M,D,Ki Young Sung,M,D,Jung-Soo Kim,M,D,and Woo-Chan Park,M,D 대한갑상선-내분비외과학회 2009 The Koreran journal of Endocrine Surgery Vol.9 No.1
Purpose: This study was performed to readjust the clinical implications of a nonrecurrent laryngeal nerve by assessing the reported Korean cases of a nonrecurrent laryngeal nerve. Methods: We analyzed the cases of nonrecurrent laryngeal nerve that have been reported in Korea between 1997 and 2008 by reviewing the literature. An internet search was conducted in the NDSL (National Digital Science Library) and the Korean Medical Database. Results: The data included 3 men and 25 women with an average age of 45.1 (age range: 28∼58). All the cases were right-sided, and the incidence rate was 0.38% and 0.86% in two articles, respectively. There was a type I variation in 4 cases (17.4%), type IIa in 19 cases (82.6%), and the others are unknown. Twenty-five cases (89.3%) had the vascular anomaly called arteria lusoria. Only 8 cases (28.6%) were preoperatively predicted as possibly having a nonrecurrent laryngeal nerve. Iatrogenic nerve injury developed in 1 case (3.57%) with a type I variation during the postoperative period. Conclusion: A similar tendency for the incidence rate, the genderratio, the type distribution and vascular anomaly was observed when comparing the Korean reports with those reports of overseas. The nonrecurrent laryngeal nerve can be preoperatively predicted if proper attention is given when vascular anomaly is noted on CT or USG, and injury will be avoided by intraoperatively following the standard operation technique. There is currently an increasing incidence of thyroid diseases, and so adequate attention must be given to the possibility of a nonrecurrent laryngeal nerve and its management. (Korean J Endocrine Surg 2009;9:24-29)
김민기(M. K. Kim),양찬영(C. Y. Yang),김보현(B. H. Kim) Korean Society for Precision Engineering 2021 한국정밀공학회 학술발표대회 논문집 Vol.2021 No.11월
본 연구에서는 미세 디스크 공구를 제작하여 초경 합금에 미세 홈(Micro Groove)을 절삭 가공하였다. 디스크 공구는 다결정 다이아몬드(Polycrystalline Diamond, PCD)가 사용되었으며, 방전 가공으로 제작되었다. 높은 회전 및 이송 속도를 가진 디스크 공구를 이용하여 적은 가공시간으로 다수의 미세 홈을 절삭 가공하였다. 방전 가공으로 공구를 제작할 때 축전 용량(Capacitance)에 따라 공구의 표면 거칠기가 변화하며, 이는 공구에 의해 절삭 가공되는 홈의 표면에도 영향을 주므로 이에 대한 분석을 수행하였다. 다수의 홈 가공 시 공구의 마모는 미세 홈의 형상 변화를 야기하므로, 이를 제어하기 위한 공구 마모를 분석하였다. 가공 시 축전 용량, 공구 형상, 공구의 회전 속도와 이송 속도 등의 조건을 변화시키며 홈의 표면 상태와 형상 정밀도를 관찰하였으며 공구 마모를 측정하여 균일한 홈 가공을 위한 최적의 조건을 결정하였다. 본 연구에서 시행한 가공 방식은 초소형 전자기기 부속품의 배선 및 방열을 위한 홈의 가공, 냉각 또는 가열을 위한 유체의 유로, 반도체 웨이퍼의 절단 등 미세 공정에서의 활용이 기대되며, 향후 이를 위해 SiC, Cu 등 타 재료에 대한 후속 연구가 요구된다.