http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Moung Jin Lee,Seong Woo Jeon,Min Jeong Jo,Won Kyong Song,Byung Jin Kang 大韓遠隔探査學會 2007 大韓遠隔探査學會誌 Vol.23 No.5
This study is aiming at improving the Environmental Conservation Value Assessment Map (ECVAM) of National Land in Korea. The ECVAM items are composed of legal and environmental/ecological assessments. A popular method applied to ECVAM is an overlay environmental/ecological assessment items. The purpose of this study is to offer complementary items of the ECVAM by examining assessment items. In this study we assessed the ECVAM by five methods. Method 1 is Grade 1 areas of each administrative district; Method 2 is comparing overlapped areas of each assessment items Grade 1, 2 and permission of each assessment items duplication; Method 3 is Grade 1, 2 areas by only singular assessment items; Method 4 is Grade 1 areas only of Method 2; and Method 5 is Grade 2 areas only of Method 2. Method 1 showed Seoul and other metropolitan cities revealed a large proportion of Grade I regions by the legal assessment items. Gang won-Do, showed a large proportion of Grade I regions by the environmental/ecological assessment item. Method 2 showed 93.4 % of diameter Grade II (standard for stability); forest diameter item accounted for 99.9 % by Method 3, Method 4 showed 95.7 % of forest diameter, and forest density accounted for 66.4 % by Method 5. This study contributes to reduce the complexity in the process of manufacturing ECVAM of National Land, and to raise the flexibility in the process of managing and updating this map.
Lee, Moung-Jin,Jeon, Seong-Woo,Jo, Min-Jeong,Song, Won-Kyong,Kang, Byung-Jin The Korean Society of Remote Sensing 2007 大韓遠隔探査學會誌 Vol.23 No.5
This study is aiming at improving the Environmental Conservation Value Assessment Map(ECVAM) of National Land in Korea. The ECVAM items are composed of legal and environmental/ecological assessments. A popular method applied to ECVAM is an overlay environmental/ecological assessment items. The purpose of this study is to offer complementary items of the ECVAM by examining assessment items. In this study we assessed the ECVAM by five methods. Method 1 is Grade 1 areas of each administrative district; Method 2 is comparing overlapped areas of each assessment items Grade 1, 2 and permission of each assessment items duplication; Method 3 is Grade 1, 2 areas by only singular assessment items; Method 4 is Grade 1 areas only of Method 2; and Method 5 is Grade 2 areas only of Method 2. Method 1 showed Seoul and other metropolitan cities revealed a large proportion of Grade I regions by the legal assessment items. Gang won-Do, showed a large proportion of Grade I regions by the environmental/ecological assessment item. Method 2 showed 93.4% of diameter Grade II(standard for stability); forest diameter item accounted for 99.9% by Method 3, Method 4 showed 95.7% of forest diameter, and forest density accounted for 66.4% by Method 5. This study contributes to reduce the complexity in the process of manufacturing ECVAM of National Land, and to raise the flexibility in the process of managing and updating this map.
Measurement of Cohesion Force between Diamond and Matrix in CMP Pad Conditioner
Kang Seung-Koo,Song Min-Seok,Jee Won-Ho 한국분말야금학회 2006 한국분말야금학회 학술대회논문집 Vol.2006 No.1
Currently Chemical Mechanical Planarization (CMP) has become an essential step in the overall semiconductor wafer fabrication technology. Especially the CMP pad conditioner, one of the diamond tools, is required to have strong diamond cohesion. Strong cohesion between diamond and metal matrix prevents macro scratch on the wafer during CMP Process. Typically the diamond tool has been manufactured by sintered, brazed and electro-plated methods. In this paper, some results will be reported of cohesion between diamond and metal matrix of the diamond tools prepared by three different manufacturing methods. The cohesion force of brazed diamond tool is found stronger than the others. This cohesion force is increased in reverse proportion to the contact area of diamond and metal matrix. The brazed diamond tool has a strong chemical combination of the interlayer composed of Cr in metal matrix and C in diamond, which enhance the interfacial cohesion strength between diamonds and metal matrix.
Song, Won Jae,Kang, Ben,Choi, So Yoon,Choe, Yon Ho The Korean Society of Pediatric Gastroenterology 2016 Pediatric gastroenterology, hepatology & nutrition Vol.19 No.2
Purpose: We aimed to investigate the efficacy and safety of adalimumab in pediatric-onset Crohn's disease patients who had failed treatment with infliximab. Methods: In this retrospective study, patients included were those who had been diagnosed with Crohn's disease before 18 years old, and had received treatment with adalimumab after infliximab failure. The efficacy of adalimumab treatment was investigated at 1 month and 1 year, and adverse events that had occurred during treatment with adalimumab were explored. Results: Ten patients were included in this study. The median duration from diagnosis to adalimumab treatment was 5.5 years (range: 2.4-7.9 years). At 1 month after adalimumab initiation, 80% (8/10) of patients showed clinical response, and 40% (4/10) achieved clinical remission. At 1 year, 71% (5/7) of patients showed clinical response, and 43% (3/7) were under clinical remission. Among the total included patients, 5 patients (50%) showed clinical response at 1 year. Primary non-response to adalimumab was observed in 2 patients (20%), and secondary failure to adalimumab was observed in 3 patients (30%) during 1 year treatment with adalimumab. No serious adverse event had occurred during adalimumab treatment. Conclusion: Adalimumab was effective for 1 year without serious adverse events in half of pediatric-onset Crohn's disease patients who had failed treatment with infliximab.
Postoperative Radiation for Soft Tissue Sarcoma
Kang,Yong-Koo,Kim,Hyoung-Min,Bahk,Won-Jong,Lee,Seong-Koo,Kim,Yun-Sil,Kim,Jung-Mang,Moon,Myung-Sang,Woo,Young-yun,Chang,Jee-Young,Yoon,Se-Chul,Song,Seok-Whan 가톨릭중앙의료원 가톨릭암센터 1994 암심포지움 Vol.- No.2
To evaluate the role of radiation and chemotherapy after limb-saving operation in the management of soft tissue sarcoma, the authors analysed retrospectively 33 patients treated in Department of Orthopaedic Surgery and Radiation Therapy, Catholic University Medical College, in terms of survival rate, local recurrence and prognostic factors. The sex distribution was 16 males and 17 females. The age distribution ranged from 16 to 81 year old with mean age of 48. The follow-up period ranged from 1 year to 10 years with average of 5.5 years. The histologic diagnoses were 9 liposarcoma(27.2%), 8 MFH(24.2%), 7 unclassifiable(21.2%), 3 rhabdomyosarcoma(9.1%), and 3 fibrosarcoma(9.1%) in orders. While marginal and intralesional margins were gained in 24 patients(72.2%), wide and radical margins were obtained only in 9 patients(27.3%). On postoperative 3 weeks, local irradiation of 5000-7000 cGy was delivered to all patients by shrinking field technique for 5-8 weeks. Of 33 patients, 16(45.5%) patients were recieved adjuvant chemotherapy in combination of adriamycin, cyclophosphamide & vicristine, or VP16 & ifosfamide based on histologic type and obtained surgical margin. The survival rates at 2 years and 5 years were 58% and 37% respectively. Local recurrences occured in 15 patients(45.5%) at average 16 months after operation. In addition, the authors considered surgical margin, presence of local recurrence and tumor size as a significant prognostic factors.
Evaluation of Dual-channel Compound Method for EBT3 Film Dosimetry
Kang, Sang-Won,Chung, Jin-Beom,Kim, Kyeong-Hyeon,Eom, Keun-Yong,Song, Changhoon,Lee, Jeong-Woo,Cho, Woong,Suh, Tae Suk Korean Society of Medical Physics 2017 의학물리 Vol.28 No.1
This study assessed the feasibility of a dual-channel (DC) compound method for film dosimetry. The red channel (RC) is usually used to ensure dosimetric quality using a conventional fraction dose because the RC is more accurate at low doses within 3 Gy than is the green channel (GC). However, the RC is prone to rapid degradation of sensitivity at high doses, while degradation of the GC is slow. In this study, the DC compound method combining the RC and GC was explored as a means of providing accurate film dosimetry for high doses. The DC compound method was evaluated at various dose distributions using EBT3 film inserted in a solid-water phantom. Measurements with $10{\times}20cm^2$ radiation field and $60^{\circ}$ dynamic-wedge were done. Dose distributions acquired using the RC and GC were analyzed with root-mean-squares-error (RMSE) and gamma analyses. The DC compound method was used based on the RC after correcting the GC for high doses in the gamma analysis. The RC and GC produced comparatively more accurate RMSE values for low and high doses, respectively. Gamma passing rates with an acceptance criterion of 3%/3 mm revealed that the RC provided rapid reduction in the high dose region, while the GC displayed a gradual decrease. In the whole dose range, the DC compound method had the highest agreement (93%) compared with single channel method using either the RC (80%) or GC (85%). The findings indicate that the use of DC compound method is more appropriate in dosimetric quality assurance for radiotherapy using high doses.