http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
A Fast Anti-jamming Decision Method Based on the Rule-Reduced Genetic Algorithm
( Jin Hui ),( Song Xiaoqin ),( Wang Miao ),( Niu Yingtao ),( Li Ke ) 한국인터넷정보학회 2016 KSII Transactions on Internet and Information Syst Vol.10 No.9
To cope with the complex electromagnetic environment of wireless communication systems, anti-jamming decision methods are necessary to keep the reliability of communication. Basing on the rule-reduced genetic algorithm (RRGA), an anti-jamming decision method is proposed in this paper to adapt to the fast channel variations. Firstly, the reduced decision rules are obtained according to the rough set (RS) theory. Secondly, the randomly generated initial population of the genetic algorithm (GA) is screened and the individuals are preserved in accordance with the reduced decision rules. Finally, the initial population after screening is utilized in the genetic algorithm to optimize the communication parameters. In order to remove the dependency on the weights, this paper deploys an anti-jamming decision objective function, which aims at maximizing the normalized transmission rate under the constraints of minimizing the normalized transmitting power with the pre-defined bit error rate (BER). Simulations are carried out to verify the performance of both the traditional genetic algorithm and the adaptive genetic algorithm. Simulation results show that the convergence rates of the two algorithms increase significantly thanks to the initial population determined by the reduced-rules, without losing the accuracy of the decision-making. Meanwhile, the weight-independent objective function makes the algorithm more practical than the traditional methods.
Kang, Jin-Han,Miao, Yan,Lee, SooYoung,Kim, Jong-Hyun,Lee, Kyung-Yil,Ma, Sang Hyuk,Jo, Dae Sun,Song, HyoYoung,Haag, Mendel The Korean Society of Infectious Diseases and Kore 2016 Infection and Chemotherapy Vol.48 No.1
<P><B>Background</B></P><P>This descriptive epidemiological study aimed to assess the prevalence of serum bactericidal antibodies against <I>Neisseria meningitidis</I> serogroups A, C, W and Y in adolescents and adults in the Republic of Korea.</P><P><B>Materials and Methods</B></P><P>In total, 987 subjects aged 11-55 years from five geographical regions of Korea were included in the study. Human serum bactericidal assay (hSBA) was used to measure hSBA titres for serogroups A, C, W and Y. Percentages of subjects with hSBA titres ≥4 and ≥8, geometric mean titres (GMTs), and associated 95% confidence intervals (CIs), were estimated. Analysis was performed for the entire study population and stratified by age group or region. No statistical hypotheses were tested.</P><P><B>Results</B></P><P>The highest percentage of subjects with hSBA titres ≥8 was observed for serogroup W (74%), was similar for serogroups C (34%) and Y (36%), and was lowest for serogroup A (9%). The percentages of subjects with hSBA titres ≥4 were similar to those with hSBA titres ≥8 for all serogroups. GMTs were 2.56 µg/mL (serogroup A), 5.14 µg/mL (serogroup C), 22.63 µg/mL (serogroup W) and 5.28 µg/mL (serogroup Y). Similar trends in GMTs across serogroups were seen for individual regions and age groups. The highest GMTs for serogroups A, W and Y were recorded in the >19-29 years group, and for serogroup C in the >49-55 years group. Across all regions, GMTs were very similar for serogroups A, C and Y, while more variation was seen for serogroup W.</P><P><B>Conclusion</B></P><P>In the Korean population, among <I>Neisseria meningitidis</I> serogroups A, C, W and Y, serum bactericidal antibodies were most prevalent against serogroup W and least prevalent against serogroup A. These trends were maintained across age groups and regions. The highest GMTs for serogroups A, W and Y were observed in the >19-29 years group. The reasons behind the observed differences in prevalence of bactericidal antibodies against the serogroups are currently not understood, although carriage and cross-reactivity of the assay may be important influences.</P>
Trichel Pulse in Negative DC Corona discharge and Its Electromagnetic Radiations
Yu Zhang,Li-Juan Liu,Jin-Song Miao,Zu-Lin Peng,Ji-Ting Ouyang 대한전기학회 2015 Journal of Electrical Engineering & Technology Vol.10 No.3
We investigate in this paper the radiated electromagnetic waves together with the discharge characteristics of Trichel pulse of negative DC corona discharge in air in pin-to-plate and wire-to-plate configurations. The feature of the current pulse and the frequency spectrum of the electromagnetic radiations were measured under various pressures and gas gaps. The results show that the repetition frequency and the amplitude of Trichel pulse current depend on the discharge conditions, but the rising time of the pulse relates only to the radius of needle or wire and keeps constant even if the other conditions (including the discharge current, the gas gap and the gas pressure) change. There exists the characterized spectrum of electromagnetic waves from negative corona discharge in Trichel pulse regime. These characterized radiations do not change their frequency at a given cathode geometry even if the averaged current, the gas gap or the air pressure changes, but the amplitude of radiations changes accordingly. The characterized electromagnetic radiations from Trichel pulse corona relate to the formation or the rising edge of current pulse. It confirms that the characterized radiations from Trichel pulse supply information of discharge system and provide a potential method for detecting charged targets.
Trichel Pulse in Negative DC Corona discharge and Its Electromagnetic Radiations
Zhang, Yu,Liu, Li-Juan,Miao, Jin-Song,Peng, Zu-Lin,Ouyang, Ji-Ting The Korean Institute of Electrical Engineers 2015 Journal of Electrical Engineering & Technology Vol.10 No.3
We investigate in this paper the radiated electromagnetic waves together with the discharge characteristics of Trichel pulse of negative DC corona discharge in air in pin-to-plate and wire-to-plate configurations. The feature of the current pulse and the frequency spectrum of the electromagnetic radiations were measured under various pressures and gas gaps. The results show that the repetition frequency and the amplitude of Trichel pulse current depend on the discharge conditions, but the rising time of the pulse relates only to the radius of needle or wire and keeps constant even if the other conditions (including the discharge current, the gas gap and the gas pressure) change. There exists the characterized spectrum of electromagnetic waves from negative corona discharge in Trichel pulse regime. These characterized radiations do not change their frequency at a given cathode geometry even if the averaged current, the gas gap or the air pressure changes, but the amplitude of radiations changes accordingly. The characterized electromagnetic radiations from Trichel pulse corona relate to the formation or the rising edge of current pulse. It confirms that the characterized radiations from Trichel pulse supply information of discharge system and provide a potential method for detecting charged targets.