RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재후보

        적외선열화상장치를 이용한 Buchanan plugger 표면의 온도상승 분석

        최성아,김선호,황윤찬,윤창,오병주,최보영,정우남,정선와,황인남,오원만 大韓齒科保存學會 2002 Restorative Dentistry & Endodontics Vol.27 No.4

        This study was performed to evaluate the temperature rise on various position of the Buchanan plugger, the peak temperature of plugger's type and the temperature change by its touching time of heat control spring. The heat carrier system 'System B' (Model 1005. Analytic Technologies, USA) and the Buchanan's pluggers of F, FM, M and ML sizes are used for this study. The temperature was set to 200℃ which Dr. Buchanan's "continuous wave of condensation" technique recommended on digital display and the power level on it was set to 10. In order to apply heat on the Buchanan's pluggers, the heat control spring was touched for 1, 2, 3, 4 and 5 seconds respectively. The temperature rise on the surface of the pluggers were measured at 0.5 mm intervals from tip to 20 mm length of shank using the infraed thermography (Radiation Thermometer-IR temper, NEC San-ei Instruments, Ltd, Japan) and TH31-702 Data capture software program (NEC San-ei Instruments, Ltd, Japan). Data were analyzed using a one way ANOVA followed by Duncan's multiple range test and linear regression test. The results as follows. 1. The position at which temperature peaked was approximately at 0.5 mm to 1.5 mm far from the tip of Buchanan's pluggers (p<0.001). The temperature was constantly decreased toward the shank from the tip of it(p<0.001). 2. When the pluggers were heated over 5 seconds, the peak temperature by time of measurement revealed from 253.3±10.5℃ to 192.1±3.3℃ in a touch for 1 sec, from 218.6±5.0℃ to 179.5±4.2℃ in a touch for 2 sec, from 197.5±3.0℃ to 167.6±3.7℃ in a touch for 3 sec, from 183.7±2.5℃ to 159.8±3.6℃ in a touch for 4 sec and from 164.9±2.0℃ to 158.4±1.8℃ in a touch for 5 sec. A touch for 1 sec showed the highest peak temperature, followed by, in descending order, 2 sec, 3 sec, 4 sec. A touch for 5 sec showed the lowest peak temperature (p<0.001). 3. A each type of pluggers showed different peak temperatures. The peak temperature was the highest in F type and followed by, in descending order, M type, ML type. FM type revealed the lowest peak temerature (p<0.001). The results of this study indicated that pluggers are designed to concentrate heat at around its tip, its actual temperature dose not correlate well with the temperature which Buchanan's "continuous wave of condensation" technique recommended, and finally a quick touch of heat control spring for 1 sec reveals the highest temperature rise.

      • KCI등재후보

        수리된 복합레진 수복물의 전달결합강도 연구

        최수영,정선와,황윤찬,김선호,윤창,오원만,황인남 大韓齒科保存學會 2002 Restorative Dentistry & Endodontics Vol.27 No.6

        This study was performed to evaluate the interfacial shear bond strength of base (direct and indirect) and repair composites with aging and surface treatment methods. Direct composites resin specimens (Charisma®, Heraeus Kulzer, Germany) were aged for 5 min, 1 hour, 24 hours, and 1 week in 37℃ distilled water before surface treatment, and then divided into five groups: Group 1, grinding; Group 2, grinding and application of bonding agent; Group 3, grinding, etching with 37% phosphoric acid for 30sec, and application of bonding agent; Group 4, grinding, etching with 37% phosphoric acid for 30sec, silane treatment, and application of bonding agent; Group 5, grinding, etching with 4% hydrofluoric acid for 30sec, silane treatment, and application of bonding agent. Indirect composite resin specimens (Artglass®, Heraeus Kulzer, Germany) were aged for 1 week in 37℃ distilled water and divided into seven groups: Group 1 - Group 5, equal to Charisma specimens; Group 6, grinding, etching 37% phosphoric acid for 60sec, silane treatment, and application of bonding agent; Group 7, grinding, etching with 4% hydrofluoric acid for 60 sec, silane treatment, and application of bonding agent. The repair material(Charisma®) was then added on the center of the surface (5mm in diameter, 5mm in height). The shear bond strength was tested and the data was analyzed using one-way ANOVA and the Student-Newman-Keuls test. The following conclusions were drawn. 1. The shear bond strength of Charisma® specimens aged for 1 hour was significantly higher in Group 2 and Group 5 than in Group 1 (p<0.05), and that of Charisma® specimens aged for 1 week was significantly higher in Group 3 and Group 5 than in Group 1 (p<0.05). No significant difference was found in the bond strength of specimens aged for 5 min and 24 hours. 2. In Group 2 of the Charisma® specimens, there was significant difference between the bond strength of 24 hours and that of 1 week (p<0.05). 3. In Group 4 of the Charisma® specimens, the shear bond strength of specimens aged for 24 hours was significantly higher than the others(p<0.05). 4. There was no significant diiference between the shear bond strength of the Artglass® specimens. 5. Most of the Charisma® specimens showed cohesive fractures. Artglass® specimens that were etched with acid(phosphoric or hydrofluoric) for 30 sec showed more cohesive fractures.

      • KCI등재

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼